Common Symptoms of the DE6612
[Viewing 1 of 1]Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Turntable Quit
Snipped four corners off inspection panel,removed one phillips screw and two elect. Connections. Reverse process.
Parts Used:
-
RICHARD from OKLAHOMA CITY, OK
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
4 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Thermostat failed because rivet was loose on connector blade; caused overheated wiring.
-
Ray from GRANBURY, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Power cuts in and out; runs for a few secs then powers off
Disconnected power and removed Microwave housing cover, observed burned end plastic connector of wire connecting to the thermostat (or thermal overload sensor); slightly wiggle one of the 2 wires to the thermostat would cause microwave power to cut out (when plugged in power). When powered on, I would try to run it but power cuts out aft
... Read more
er just a few seconds. Removed the 2 wires from the old thermostat, removed the 2 screws that fasten down the thermostat, replaced with new thermostat and reapplied the 2 screws; cut off burned part of wire and resolder to new wire connector; reconnect both wires to new thermostat and reinstall MW housing cover. MW works good as new again. Thank you PartSelect!
Read less
Parts Used:
-
Vinh from Houston, TX
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
Was this instruction helpful to you?
Thank you for voting!