Models > 75121

75121 LG Air Conditioner - Overview

Sections of the 75121

[Viewing 1 of 1]

Exact Part matches for your search term

[Viewing 4 of 4]
TRUNNION – Part Number: 75121
TRUNNION
This part number matches the current model number 75121
PartSelect #: PS1297785
Manufacturer #: 75121
  No Longer Available
Screw – Part Number: 75121
Screw
This part number matches the current model number 75121
PartSelect #: PS11984556
Manufacturer #: 75121
  No Longer Available
Screw – Part Number: 75121
Screw
This part number matches the current model number 75121
PartSelect #: PS12230145
Manufacturer #: 75121
  No Longer Available
Pressure washer extension hose, 25-ft – Part Number: 75121
Pressure washer extension hose, 25-ft
This part number matches the current model number 75121
PartSelect #: PS16870184
Manufacturer #: 75121
  No Longer Available
Keep searches simple, eg. "belt" or "pump".
FAN,AXIAL – Part Number: 5900A10009E
FAN,AXIAL
★★★★★
★★★★★
(7)
PartSelect #: PS12747824
Manufacturer #: 5900A10009E
The condenser fan blade fits onto the air conditioner motor shaft. The fan blade helps circulate air over the condenser to cool the refrigerant before it enters in to the evaporator. This part is beig...
$48.05
  In Stock
Order within the next 8 hrs and your part ships today!

Questions And Answers for 75121

Be the first to ask our experts a question about this model!

Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Broken fan axial blade
Unscrewed the unit from the exterior case pulled out the unit unscrewed the 4 screw that hold the fan shroud carefully unscrewed the coil pulled back unclipped the axial fan clip gentlyhit with rubber mallet replacement of new fan replaced clip
15 minutes best investment of 20 bucks as apposed to 400 $
Parts Used:
FAN,AXIAL
  • John from HARLINGEN, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
window a/x unit fan broke
took apart the fan housing and replaced the fan saving me hundreds of dollars from buying a new unit
Parts Used:
FAN,AXIAL
  • margaret from CARRIERE, MS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
6 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!