Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Ice buildup in the door of freezer
Pulled the ice/water control panel off using the three holes under the lip. Pops off pretty easy. Next came 4 screws holding the chute for the ice. Two bottom screws were very rusty, top two look brand new. Watch the wires. Replace the solenoid assembly by unplugging wires leading to the board, then removed the plunger over the top of the hook on the far right. Went ahead and replaced the dispenser door assembly or flapper. Plugged refridge back in and pressed the ice dispenser handle and listened for the solenoid to cycle. Perfect. There is a little delay before you hear the flapper fall into place. Saving rest of parts just in case they are needed next time.Thanks to everyone who wrote in to show how easy it would be. No telling how much a repairman would have charged me.
dropped something on the light switch and it broke off
we just pried out the old switch and pulled it out the rest of the way with a pair of needle nose pliers. Pulled off the wires on the broken switch and reattached to the new one and just slid/clicked it back into the hole.
After advise from the expert, he was adamant the motherboard was the (via symptoms)problem. After receiving the replacement board (via FEDEX), I followed the easy to understand instructions. I did number the electrical plugs and mapped the connections on paper. The key to the rapid fix was to carefully read all of the instructions to verify which (if any) wires needed elimination, which in my case was none. I will definitely use this service in the future as the expense was affordable and after research, I estimate a savings between 55% to 60%.
refrigerator/freezer defrosting completely for no reason
Unplugged refrigerator and used a screwdriver to remove access panel on rear of refrigerator to expose "mother board". Unplugged connectors (6 total) and using needle nose pliers released two retainers to remove mother board. Installed new mother board snapping it onto the two retainers and plugged the connectors onto the new mother board. Plugged refrigerator into outlet, refrigerator came back on, automatically reset it's temperature settings and has been working fine since. Total time, less than 15 minutes. Money saved, hundreds of dollars!
Had previously replace the plastic Water Tank, but when installing it I didn't realize how the quick connects worked. Instead of simply pushing inward in the direction of the blue part of the disconnect, I had pulled out the white ring on the outside of the disconnects. This ruined the inside connections and caused them to leak thus requiring these repairs. Had I known that I wouldnt have bought these parts too. Just Always REMEMBER to push in outside white ring on the quick disconnect and as you push it in pull out the hose when you remove it. To put the hose back in, just push it back in without pushing on ring this time at all and it will lock in place, and shouldn't be leaking. I had to run water into a glass to test if it was leaking, otherwise the line had no water pressure.
It appeared that the helix lock wore out first, then the cutter teeth dug into the side of the plastic housing. Then the cup drive broke in half from the helix being jammed. Removed the ice bin from the refrigerator. removed 4 screws around the edge of the bin. Pry open clips that hold the auger assembly in place. Remove the clip from the end of the auger. Pry old plate helix lock from holder. Pull out helix auger removing cutters and keeping everything in order. Replace old plate helix lock with new one. Replace cutters in order and tighten nut and install clip. Put new cup drive on end of helix. Snap assembly back together. Replace screws.
Not cold & saw ice accumulated on freezer back panel
-Disconnect the power supply wire& turn temp control inside refrigerator to 0! -15 mins spent on remove (5 screws) the back panel inside freezer, melt ice then replace the heater (2 screws) on the bottom! Black wire on left & pink wire on the right! Make sure both end has good connection to the heater!
-30 mins to drain all water from the bottom (back side) of the refrigerator, suck & clean all dust & dirt from the front & back side!
-Set both temp control knots to 5 & put back all the food!
-If no ice build up on the panel after 10 days & then the repair is good!
installed new double water outlet and tube assembly and it fixed the promblem. I think the water valve was leaking by causing the tube to freeze up inside.
Fridge smelled like something electronic was burning
Removed the back cover of the fridge with it still pluged in. The next time the compressor tried to kick on, a small piece of black plastic next to the black tank caught fire, and then went out. I unpluged the fridge, unpluged the two wires feeding the black box. Then the box unpluged from the tank. I searched on the internet for the part using the model #. It ended up being a overload/ptc or relay. There was a smaller black box attached with I think is some sort of an overload. I unplugged the overload and it plugged right into the new relay I had overnighted. Although the new relay was white (not black) and the plug attachments were in different locations, it work great.
Removed the cover on the bottom of the rear of the fridge and the top left of the fridge where the tubbes exit.. Then just simply disconnect the tube coming from the fridge and the supply line. Next go inside the fridge, remove the cover of the filter mount, and remove the 2 screws securing the filter mount in place. Now pull the tubes through the opening and reinstall in reverse order.
went to your website and viewed exploded view to find the sensor( there are two I just picked one to replace for now), pried the cover off carfully and pulled out the sensor. I snipped the wire in the middle leaving plenty to work with. I shortened the wire on the new piece, spliced the wires together and with some 3M rubberized, tape wrapped them up, replaced the sensor back into the cover and snapped in place.
Ice door would not open far enough, ice would get stuck in chute
First remove about 30 screws w/nutdriver that are hidden under door seal then inside of freezer door will come off. Second remove about 10 screws that hold dispenser assy to the inside of door, then support the unit with tape so you don't damage the wires that connect it. Third, pop touchpad loose, then remove three sets of wires plugged into the circuit board. Fourth, remove four screws that hold the ice chute and light assy. Fifth, now remove the 3 screws that hold solenoid. These three screws that hold the solenoid will be very rusty, you may want to replace these also. I went ahead and replaced all the related parts because they are so hard to get to. Also took the opportunity to clean in here with bleach to remove all the black mold and rust. NOTE: when reassembling the inside of the freezer door to the outside of the door you must loosely attach the door on both sides in the middle first, then the top and bottom. Add some more screws on each side and tighten them all. Now you must check to be sure that the door is not racked. If the door is not sealed at the top or bottom, loosen the screws and twist the door a little and tighten screws and check door again for proper seal. Spent more time adjusting door to seal right than doing the actual repair.
put fridge into test mode, failed One sensor. Took it out, Tested it, Ordered part also picked up splice kit from electric store spliced it truned on and good to go
Ordered parts from another vendor - got wrong parts (1/4 in parts instead of 5/16 in parts). With your parts, I just cut out the bad portion of the tubing, and replaced it using the 2 union connectors. Thanks.
Freezer would not defrost and ice would accumulate on the coils. After the GE repairman quoted me a price to defrost and repair it – which was ridiculous – I decided to tackle the problem myself. I am posting this comment as I found other comments very helpful with trouble shooting my problem. After reviewing other home owner repair comments I decided to first replace the upper sensor, thermostat and heater bracket assy. The longest task to do this was defrosting the coils. What a mess that turned out to be. The items were fairly easy to replace. The sensor and thermostat needed to be spliced and I used good techniques and sealed the splices with electrical tape. Defrost thru repair was about 3.5 hours. Unfortunately, this did not solve the problem and the temperature started rising after the coils froze over again. I decided to go one step further and replace the main board. One repair comment said that it is important to completely remove all of the frost before engaging the new main board – which made sense to me. The defrosting was easier and faster the second time as I plugged the drain below the coils, used hot water and then my shop wet vacuum to remove all the defrost water. Then I reversed the air flow to completely dry the coils. The main board installation instructions were fairly easy to follow. I took a picture with my camera just to ensure all the wires were installed properly. However, that was not necessary the plugs are unique and will only fit one way. The only problem was plugging in the power connector as it was in a different location on the board. With a little careful nudging it was successfully installed. Overall, a good experience and I am thankful for these repair comments by other!