Water continuously pours out of the icemaker
A week earlier, we had frozen water all over the freezer section which obviously dripped from the icemaker. We turn off the icemaker and cleaned the freezer. Upon turning the icemaker back on, water continuously pours out of the ice tray. This time, even turning off the icemaker does not stop the water from flowing through. I checked and cleaned the water valve, reinstalled it and it still does not work. I had to crimp the water line and even remove the water filter to make sure there will be no water leaks.

When I got the new water valve, installation was a snap as I have already removed the old one. After installing the new valve and putting back the filter, everything is back to normal.

Procedure for removing/replacing the water valve:
(1) Unplug the refrigerator and move it so that you have some working space in the back. If there is a mechanical valve in the water line, close it so that when the hoses are unplugged, there will be no spills. If there is no mechanical water valve, you can simply crimp the hose with a rubber band or a cable tie.
(2) Use an adjustable wrench or a screw driver to remove the screws on the bottom panel. My refrigerator has 4 big screws and 1 small one that is used to anchor the water hose.
(3) Pull the panel up slightly to remove it. The water valve is mounted with one screw at the bottom-left corner.
(4) Use a screwdriver to dismount the water valve.
(5) Unplug the electrical connections to the water valve. My refrigerator has one Brown and one Blue connector. Remember which plug goes to which connector.
(6) Place a towel under the water valve and use the adjustable wrench to remove the main hose connection.
(7) Next, remove the hoses that to into the water valve outlets. On my refrigerator, these hoses are of different sizes and have quick-disconnects. I simply have to press on the collar at end of the hose, pushing it towards the valve to release the hose, then pull on the hose.
(8) Prepare the new water valve by removing the plastic cover that protects the connector for the main water line.
(9) Connect the main water line to the new valve using the adjustable wrench.
(10) Connect the two hoses of different sizes to the valve. You only have to push them all the way into each valve and slightly tug on them to make sure they are locked in place.
(11) Re-connect the Brown and Blue electrical connectors to their original location.
(12) Mount the new water valve into the back of the refrigerator (one screw).
(13) If possible, quickly check that the new valve is working properly: If you have a mechanical valve in the water line, open it and make sure there are no leaks near the valve or inside in the icemaker. You may have to plug in the refrigerator power to complete the initial test.
(14) Replace the back panel with the 4 screws and anchor the hose to the back with 1 screw.
(15) Once everything is back in its place and the refrigerator is on, cycle the water dispenser several times to run fresh water into the hoses and the new valve.
Parts Used:
WATER VALVE WITH GUARD
  • Noel from San Jose, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
72 of 78 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped working
I unplugged the electrical connection. Then I removed the 2 screws holding the icemaker in place. I lifted out the old icemaker unit and put the new one in place. Then put the 2 screws back in and plugged in the new unit.

The icemaker started making ice very soon after turning the unit on.
Parts Used:
Ice Maker
  • Dan from West Bloomfield, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
82 of 109 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice jamming up in the ice maker unit because auger was broken
Remove Ice maker bin from the refrigerator and empty. Unscrew the three Phillips head screws that secure the front plate to the bin and gently lift and pull the tab that secures the interior portion of the plate until it clears the bin. Once you remove the front plate, it will expose two side tabs on the front of the bin which must be depressed so that the plastic insert that hold the auger in place can be removed. Isolate the auger with the from the unit by rotating the parts off the shaft. The ice crushing blades are attached to the auger and can easily be removed by twisting the plastic nut off with pliers. The cutting blades will now slip off the end (make sure you study the orientation of the blades as each piece will come off separately and make the job unpleasant when you go to put it back together). Now that the auger is out, just reverse the process and you have a "new" ice dispenser. Works like a charm. The diagram furnished by PartSelect was very helpful and accurate if you get a bit lost, especially when putting the crushing blades back together.
Parts Used:
BUCKET AUGER
  • Elaine from Healdsburg, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
77 of 95 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken ice maker part
used a screwdriver to remove screw and unplugged part. Plugged in new one and secured with a screw.
Simple
Parts Used:
Ice Maker
  • Laura Beth from Mandeville, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
76 of 99 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan not running
Removed rear and front grills,brushed and vacuumed area- probably caused the fan motor to fail- unplugged fan, removed fan,motor,and shroud in 1 piece, carefully slipped fan off motor shaft, unscrewed shroud and motor. assembled in reverse order. Frige is in tight area, .I'll now roll it out and clean often
Parts Used:
DC Condenser Fan Motor - 12V
  • Ray from Bensalem, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
74 of 102 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Recessed door on ice dispenser would stay open causing the freezer to frost up
I inserted the tip of a very small screwdriver from a eye glass repair kit into the three small holes under the panel near where the ice is dispensed. I never would have known about this simple procedure if it wasn't for the feedback you post from your parts cumtomers. Once I did this the front panel with the buttons on it poped off and it was just a matter of removing a few screws at that point. The wires from the new solenoid easily plugged into the board on the front panel. I would recommend changing the screws at the same time. The old one's worked but they were rusty. I feel the solenoid was my only problem but I changed all the parts in between the dispenser door and the solenoid just to be sure.
Parts Used:
Dispenser Door Solenoid Assembly Dispenser Door Assembly or Flapper Door Recess Retainer Dispenser Door Recess Crank Recess Door Spring
  • Turcotte's Housing Service, In from Newmarket, NH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
70 of 92 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replaced the cracked plastic ice auger
Removed the ice bucket assembly and attempted to dismantle and re-assemble it the same as new
after replacing the auger. I wish the part was shipped with replacement instructions because a simple job turned into a major headache for me because of the following:
1) I did not realize that the the nylon nut at the end of the auger rod assembly has a reverse thread. By the time I had it removed using vice-grip pliers and a bench vice.....the nut threads were stripped.
2) When removing the nylon washers, spacers, metal cutters from the old auger rod, I grabbed the entire grouping hoping to drop them on the new auger rod as a group. While doing so, the pieces slipped out of my hand and It was very difficult to find the correct order of configuration even with the on-line parts photo. I would recommend that you number each part before removing them from the rod because there is only 1 way all of these pieces can be re-assembled to work as designed.
Parts Used:
BUCKET AUGER
  • Michael from Greenbelt, MD
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Pliers, Screw drivers
67 of 84 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bad Ice Auger Motor
Things I learned...remove only the two far left screws and one far right screw from the ice auger motor mounting plate. Disconnect both wiring harness connectors. With the assembly removed from the freezer, you'll need to get the motor seperated from the drive mechanism (fork). This was the most difficult part of the repair. The reason is that the fork (which is reverse threaded) cannot be unthreaded independantly of the motor shaft (ie. they both turn together). Locking pliers on the shaft only stripped metal from the shaft and did not supply enough torque to remove the fork. The way I finally did it was to take the old motor partially apart, then lock the gear case (keeping the shaft from rotating) with the motor's own splined internal rotor shaft. Once I finally got the fork apart from the motor shaft, swapping out motors was simple. You'll need to put the old plastic glove on the new motor to keep it dry. Also, the replacement motor I got from partselect.com did not come with threaded mounting bolt holes. Therefore, I had to use slightly larger self tapping screws I got from the hardware store. I also used locking washers as the assembly is subject to vibration.
Parts Used:
Auger Motor
  • Mark A. from Port Byron, IL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Pliers
57 of 67 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water Leaking @ Quick Releases (Blue and White)
Had previously replace the plastic Water Tank, but when installing it I didn't realize how the quick connects worked. Instead of simply pushing inward in the direction of the blue part of the disconnect, I had pulled out the white ring on the outside of the disconnects. This ruined the inside connections and caused them to leak thus requiring these repairs. Had I known that I wouldnt have bought these parts too. Just Always REMEMBER to push in outside white ring on the quick disconnect and as you push it in pull out the hose when you remove it. To put the hose back in, just push it back in without pushing on ring this time at all and it will lock in place, and shouldn't be leaking. I had to run water into a glass to test if it was leaking, otherwise the line had no water pressure.
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch WATER VALVE WITH GUARD
  • randy from vancouver, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench set
57 of 70 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Gasket wasn't sealing
Replaced gasket. No tools requires. Just pull the old one out and press new one in channel with hands. TIP: heat the new one slightly with a hair dryer or a heat gun on low. Makes it more flexible
Parts Used:
Fresh Food Door Gasket - Black
  • Joe from Succasunna, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
51 of 59 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Not cold & saw ice accumulated on freezer back panel
-Disconnect the power supply wire& turn temp control inside refrigerator to 0!
-15 mins spent on remove (5 screws) the back panel inside freezer, melt ice then replace the heater (2 screws) on the bottom! Black wire on left & pink wire on the right! Make sure both end has good connection to the heater!

-30 mins to drain all water from the bottom (back side) of the refrigerator, suck & clean all dust & dirt from the front & back side!

-Set both temp control knots to 5 & put back all the food!

-If no ice build up on the panel after 10 days & then the repair is good!
Parts Used:
Defrost Heater and Bracket Assembly
  • Eddie from Freeport, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
52 of 64 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker tube would freeze up
installed new double water outlet and tube assembly and it fixed the promblem. I think the water valve was leaking by causing the tube to freeze up inside.
Parts Used:
WATER VALVE WITH GUARD Grommet / Tube Assembly
  • Ed from Chesterfield, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
50 of 59 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fridge side freezes some items
went to your website and viewed exploded view to find the sensor( there are two I just picked one to replace for now), pried the cover off carfully and pulled out the sensor. I snipped the wire in the middle leaving plenty to work with. I shortened the wire on the new piece, spliced the wires together and with some 3M rubberized, tape wrapped them up, replaced the sensor back into the cover and snapped in place.
Parts Used:
Temperature Sensor
  • Anthony from Murfreesboro, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
54 of 75 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice door would not open far enough, ice would get stuck in chute
First remove about 30 screws w/nutdriver that are hidden under door seal then inside of freezer door will come off. Second remove about 10 screws that hold dispenser assy to the inside of door, then support the unit with tape so you don't damage the wires that connect it. Third, pop touchpad loose, then remove three sets of wires plugged into the circuit board. Fourth, remove four screws that hold the ice chute and light assy. Fifth, now remove the 3 screws that hold solenoid. These three screws that hold the solenoid will be very rusty, you may want to replace these also. I went ahead and replaced all the related parts because they are so hard to get to. Also took the opportunity to clean in here with bleach to remove all the black mold and rust.
NOTE: when reassembling the inside of the freezer door to the outside of the door you must loosely attach the door on both sides in the middle first, then the top and bottom. Add some more screws on each side and tighten them all. Now you must check to be sure that the door is not racked. If the door is not sealed at the top or bottom, loosen the screws and twist the door a little and tighten screws and check door again for proper seal. Spent more time adjusting door to seal right than doing the actual repair.
Parts Used:
Dispenser Door Solenoid Assembly Dispenser Door Assembly or Flapper Micro Switch Dispenser Door Recess Crank Recess Door Spring
  • ERIC from MADISON, AL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
73 of 133 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer cold / fridge warm
put fridge into test mode, failed One sensor. Took it out, Tested it, Ordered part also picked up splice kit from electric store spliced it truned on and good to go
Parts Used:
Temperature Sensor
  • Mark from Mancos, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
46 of 54 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the DSE25JMHBCES