Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Ice jamming up in the ice maker unit because auger was broken
Remove Ice maker bin from the refrigerator and empty. Unscrew the three Phillips head screws that secure the front plate to the bin and gently lift and pull the tab that secures the interior portion of the plate until it clears the bin. Once you remove the front plate, it will expose two side tabs on the front of the bin which must be depressed so that the plastic insert that hold the auger in place can be removed. Isolate the auger with the from the unit by rotating the parts off the shaft. The ice crushing blades are attached to the auger and can easily be removed by twisting the plastic nut off with pliers. The cutting blades will now slip off the end (make sure you study the orientation of the blades as each piece will come off separately and make the job unpleasant when you go to put it back together). Now that the auger is out, just reverse the process and you have a "new" ice dispenser. Works like a charm. The diagram furnished by PartSelect was very helpful and accurate if you get a bit lost, especially when putting the crushing blades back together.
Freezer compartment would freeze sold so the fridge would go warm.
Emptied the fridge and freezer. Unplugged it and in so do doing defrosted the freezer coils. Replace the listed parts, for they were right there easy to get at and replace. Between the three of them we had an 80% chance of getting what was wrong. The freezer and the refridgerator are both working just fine. No more warm milk.
Recessed door on ice dispenser would stay open causing the freezer to frost up
I inserted the tip of a very small screwdriver from a eye glass repair kit into the three small holes under the panel near where the ice is dispensed. I never would have known about this simple procedure if it wasn't for the feedback you post from your parts cumtomers. Once I did this the front panel with the buttons on it poped off and it was just a matter of removing a few screws at that point. The wires from the new solenoid easily plugged into the board on the front panel. I would recommend changing the screws at the same time. The old one's worked but they were rusty. I feel the solenoid was my only problem but I changed all the parts in between the dispenser door and the solenoid just to be sure.
Removed the ice bucket assembly and attempted to dismantle and re-assemble it the same as new after replacing the auger. I wish the part was shipped with replacement instructions because a simple job turned into a major headache for me because of the following: 1) I did not realize that the the nylon nut at the end of the auger rod assembly has a reverse thread. By the time I had it removed using vice-grip pliers and a bench vice.....the nut threads were stripped. 2) When removing the nylon washers, spacers, metal cutters from the old auger rod, I grabbed the entire grouping hoping to drop them on the new auger rod as a group. While doing so, the pieces slipped out of my hand and It was very difficult to find the correct order of configuration even with the on-line parts photo. I would recommend that you number each part before removing them from the rod because there is only 1 way all of these pieces can be re-assembled to work as designed.
Water valve was leaking by and overfilling icemaker tray
Turned off the water supply valve to the refrigerator. Removed the rear access panel (6 screws) and the one screw mounting the water valve. Slid the water valve out and disconnected the two electrical plugs and two outlet tubes (slip/lock fit) and the inlet supply (ferrel nut). Connected the three tubes to the new valve, the two power plugs, slid valve back in place and reinstalled the mounting screw. Turned on the water supply valve back on and checked for leaks - none. Reinstalled the rear access panel and tightened all screws. Checked the icemaker and cleaned the input tube and tray, ensured all were properly mounted and aligned. Restarted icemaker and and checked the operation periodically over the next day. All worked properly.
The evaporator fan motor stopped running, freezer was warmer than normal
First ,I placed all the frozen food from the freezer into the lower fridge compartment. Removed the main shelf. Removed the ice cube tray shelf. Removed the center plastic covers using a nut driver. Removed the complete inside back wall of the freezer to get access to the fan. Simply removed about 5 screws, and cut 3 tie straps that held the wiring in place. Unplugged the fan connector and removed fan with its brackets and placed them on the kitchen table. Then used the nut driver to remove 2 screws which hald the fan to its bracket. Simply pulled off the fan blades and pressed them onto the new motor. Mounted new motor onto the bracket. Reinstalled the fan assembly back into freezer. Reconnected the wiring and the fan began to run... BE CAREFUL NOT TO TOUCH THE FAN WITH YOUR FINGERS! Finally replaced all the covers, panels, and shelf etc. and everything is once again nice and cold.
Things I learned...remove only the two far left screws and one far right screw from the ice auger motor mounting plate. Disconnect both wiring harness connectors. With the assembly removed from the freezer, you'll need to get the motor seperated from the drive mechanism (fork). This was the most difficult part of the repair. The reason is that the fork (which is reverse threaded) cannot be unthreaded independantly of the motor shaft (ie. they both turn together). Locking pliers on the shaft only stripped metal from the shaft and did not supply enough torque to remove the fork. The way I finally did it was to take the old motor partially apart, then lock the gear case (keeping the shaft from rotating) with the motor's own splined internal rotor shaft. Once I finally got the fork apart from the motor shaft, swapping out motors was simple. You'll need to put the old plastic glove on the new motor to keep it dry. Also, the replacement motor I got from partselect.com did not come with threaded mounting bolt holes. Therefore, I had to use slightly larger self tapping screws I got from the hardware store. I also used locking washers as the assembly is subject to vibration.
Ice maker failure due to chunks of ice building up in tray
My problem began with having to replace the auger due to damage (broken blade). Unknown at that time the unit was having a defrost cycle issue. Once auger was repaired, then the motor to auger failed. Once repaired the GE unit then began shutting down without warning. Mother board replaced. All was fine for two weeks then noticed odd performance by ice-maker (chunks of Ice again)and frozen package containers showing signs of dampness and then refreezing. Read through the Parts Select web site to see what other users may have had gone wrong with their GE's and what the parts overview section may reveal for me. Found that the defrost thermo and temp-sensor controlled defrost functions. The parts were cheap, $20.00 for the pair so I replaced them both since they are both located next to one another in the freezer compartment. The repair video furnished on the P/S web was great and very accurate. The entire job only took about an hour. The repair video indicated using wire-nuts and electircal tape Instead, I chose to solder the wires and use shrink-tubing to provide the moisture barrier. PartSelect folks are great not only for their parts pricing but also for the informative videos. The GE works better than ever
1) Unplugged fridge and removed cover over light in freezer. 2)Removed screws holding cover over motor. 3) Removed screws on bracket holding motor in place. 4) Un plugged motor and used razor blade to cut grommet holding wires in place. 5) Plugged in new motor and routed wires through grommet. Then used zip ties to hold grommet together. 5) Re-attached motor bracket and installed new fan. 6) Reinstalled cover over motor.
Not cold & saw ice accumulated on freezer back panel
-Disconnect the power supply wire& turn temp control inside refrigerator to 0! -15 mins spent on remove (5 screws) the back panel inside freezer, melt ice then replace the heater (2 screws) on the bottom! Black wire on left & pink wire on the right! Make sure both end has good connection to the heater!
-30 mins to drain all water from the bottom (back side) of the refrigerator, suck & clean all dust & dirt from the front & back side!
-Set both temp control knots to 5 & put back all the food!
-If no ice build up on the panel after 10 days & then the repair is good!
Fridge smelled like something electronic was burning
Removed the back cover of the fridge with it still pluged in. The next time the compressor tried to kick on, a small piece of black plastic next to the black tank caught fire, and then went out. I unpluged the fridge, unpluged the two wires feeding the black box. Then the box unpluged from the tank. I searched on the internet for the part using the model #. It ended up being a overload/ptc or relay. There was a smaller black box attached with I think is some sort of an overload. I unplugged the overload and it plugged right into the new relay I had overnighted. Although the new relay was white (not black) and the plug attachments were in different locations, it work great.
went to your website and viewed exploded view to find the sensor( there are two I just picked one to replace for now), pried the cover off carfully and pulled out the sensor. I snipped the wire in the middle leaving plenty to work with. I shortened the wire on the new piece, spliced the wires together and with some 3M rubberized, tape wrapped them up, replaced the sensor back into the cover and snapped in place.
Ice door would not open far enough, ice would get stuck in chute
First remove about 30 screws w/nutdriver that are hidden under door seal then inside of freezer door will come off. Second remove about 10 screws that hold dispenser assy to the inside of door, then support the unit with tape so you don't damage the wires that connect it. Third, pop touchpad loose, then remove three sets of wires plugged into the circuit board. Fourth, remove four screws that hold the ice chute and light assy. Fifth, now remove the 3 screws that hold solenoid. These three screws that hold the solenoid will be very rusty, you may want to replace these also. I went ahead and replaced all the related parts because they are so hard to get to. Also took the opportunity to clean in here with bleach to remove all the black mold and rust. NOTE: when reassembling the inside of the freezer door to the outside of the door you must loosely attach the door on both sides in the middle first, then the top and bottom. Add some more screws on each side and tighten them all. Now you must check to be sure that the door is not racked. If the door is not sealed at the top or bottom, loosen the screws and twist the door a little and tighten screws and check door again for proper seal. Spent more time adjusting door to seal right than doing the actual repair.
put fridge into test mode, failed One sensor. Took it out, Tested it, Ordered part also picked up splice kit from electric store spliced it truned on and good to go