Refrigerator fan motor died
It has been my experience that these motors sometimes die when the refrigerator is overfilled and motor strains to keep refrigerator cold. And this motor is used in several models of refrigerators. That said, sometimes the hook-up is slightly different between other units. The available video is good, but like I said, circumstances will be slightly different between various models.
After cleaning out freezer (plug disconnected first), start to remove outer plastic covers. If you want to keep track of the different steps, you can take pictures with your cellphone. And if there are any connecting wire attachments you think you might not remember, again, you can take a picture, or label with tape (colored tape, or by writing on the tape). And for keeping track of the different-size screws, I place them in a muffin tin, keeping an order of left to right and top to bottom in the tin. When removing Styrofoam blocks in bottom center, make sure you remove any remaining ice underneath in the hole so refrigerator can "breathe". Freezer air is moved below to refrigerator compartment, so a blocked vent hole will strain refrigerator as it tries to maintain its temperature setting and can be the cause of your failed motor.
After replacing motor onto bracket with grommets and blade, don't completely tighten. Position plastic cover with hole opening over motor and blade assembly. Twirl motor blade to see if there is any interference with cover. If not, take away cover and tighten motor on bracket. If there is any rubbing, adjust motor/blade assembly accordingly before tightening in place. Putting everything back together is in reverse order.
Despite attempts to quiet the 2 year old fan, I went ahead and replaced it. Part Select was prompt with a new one at my door less than 24 hours. It was just the fan motor, so took a couple extra steps to place it in the metal housing, but no problems and though the frig still makes noises, it's not coming from the fan as before.
I used pliers to pull lightly on the head of the switch, while I inserted a small flat head screw driver into the base of switch and gently worked around the edges to free it from the panel.
I haven’t received the wheel yet. Originally ordered on Dec. 13. Hadn’t received it by Dec. 20. Finally shipped on Dec. 22. Tracking said it was expected to be delivered on Jan.2. Not delivered. Then it said it was still on its way but it was unknown when it would be delivered. Still waiting on Jan. 6. By far the most expensive economy shipping ever, as this refrigerator is in a rental that can’t be rented until a wheel is installed.
EVAP fan motor wore out, fan hits flange in back panel
Took back out of freezer compartment, pulled plug and removed old motor, inserted new parts. It was easy and the parts arrived the day after I ordered online, even though I chose the cheapest shipping option. Nothing in my freezer had a chance to thaw out.
Shelf cracked when less than year old. and has gotten progressively worse thru the years. Replaced in seconds , no tools required . I should have done this years ago
vegetable vegetable pan lid was cracked and I wanted another wire shelf.
The parts came the next day after ordering and I didn't pay for fast shipping. I removed the drawers and the old lid-shelf and replaced it with the new one; also added an extra shelf. I love the new items and they fit perfectly.
The old switch was hard to remove. Thinking that I may have to loosen the wires I used a socket wrench to remove a clamp. This was unnecessary. In the end the switch did come out using a large size screwdriver. The problem was that the expanding plastic tongue is not visible from the ouside so you have to try to feel your way around. If i had ordered the replacement before and not afterwards I would have seen this before hand.
After replacing the light bulb and still no light I manually pushed the light switch button. Intermittently the light would come on then go out. I removed the power plug from the power source then replaced the light switch. I plugged the refrigerator back in and now I open the door the light comes on and stays on until the door is closed.
The unit cycles but does not achieve proper temperature
Remove power from the unit. With short length #2 Phillips loosen and remove the two(2) screws on the control panel located center top of the refrigeration area. Slide the control panel back about 1/2 inch and allow it to dangle from its wiring harness. Pinch the locking tab on the harness connector with one hand and use the other hand to separate the two sides. A little force is required. Remove the control panel from the refrigerator and shut the refrigerator door. Examine and note the routing of the temperature probe (Silver colored flexible wire) take a picture for later reference. Remove the old and replace with new unit. route temperature probe like the replaced unit. Reverse the steps and reinstall the control panel. It is a good idea to also purchase and replace the defrost timer.