Refrigerator not getting cold
Replaced Temperature Sensor and now it is getting cold.
Parts Used:
Temperature Sensor
  • Dan from COLUMBIA, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defroster thermostat was bad
take the metal cover off the defrost thermostat is on top of the coil take the thermostat off from the coil cut the two wires take the wire and strip the ends off take the new thermostat the wires are color coded wire them together put the thermostat back on coil your done real easy
Parts Used:
Defrost Thermostat
  • ralph e from CARYVILLE, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Loud Squeal when fan was running
WE (WIFE) took out the old parts an replaced with new one ..Be careful to get the placement of the Grommet or they "POP" out on you. fast ship on the parts too.
Parts Used:
Evaporator Fan Grommet - Grey
  • Daniel from BURNEY, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Side by side fridge and freezer both hot warm and the inside back panel of the freezer all frosted
As per the video , I unplugged the appliance and defrosted the freezer . Then removed the shelves and back from the freezer. Located and removed the old parts and installed the new ones which took about 20 minutes. Reassembled the appliance, plugged it in and it was cold within a few hours. Thanks for all the help
Parts Used:
Defrost Thermostat Temperature Sensor
  • Jamie from WINCHESTER, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer working but fridge not cooling.
Totally followed the instructions of the video that came with the sensor. Unplugged the the fridge, defrosted the freezer. Cut off the main sensor that usually is the one that goes out. Installed the the new sensor with new wire terminals, crimped them and covered with electrical tape. Fridge works like a charm. Partsselect is excellent. Saved me a few hundred dollars versus having a GE Tech come and do it.
Parts Used:
Temperature Sensor
  • Kent from Bartlesville, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Everything freezing in fridge
This was generally an easy fix. The work was in such a confined area of our side by side and my husbands shoulders are broad so that was a little more challenging but overall a quick, easy and cheap repair doing it ourselves without having to call a appliance repairman.
Parts Used:
Defrost Thermostat
  • lois from hesperia, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice on the frezer compartment
turn off the refrigerator,then open the cover and saw lot of ice. then get a hair dryer blower and blow a heat to melt the ice. cut the thermostat defrost.
Parts Used:
Defrost Thermostat
  • Rafael from New Haven, CT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refridgerator warm, some ice buildup apparent in freezer
Find online diagram of freezer section for reference. Disconnect power, remove evap cover plate (214) by removing one of the drawer guide rails.

As evidence of your problem, you might see a giant block of ice built up around the coil. Let this defrost this before continuing.

Find THERMOSTAT DEFROST (24) sensor and clip connecting wires. Match replacement sensor wires by color. Twist and solder wires; or wire-nuts and twisting alone might be okay. If not soldering, seal the wire-nuts connections from moister with a good sizeable piece of duct tape. Make sure your wires are out of the way and not left dangling on the evap heater coil, where they could melt.

Suggest concurrent replacement of evap fan motor if this has not already been done in the past.. This become noisy with age and damage from the ice build up seems to have made mine worse.
Parts Used:
Defrost Thermostat
  • Mahvash from Gold Canyon, AZ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Rear of freezer all iced up would not defrost
first removed two srews removed rear panel hair dryer to melt ice (took 30 minutes) cut two wires to thermostat spliced onto new part clipped it onto tube -done replace rear panel and 2 screws. very easy job after reading other letters and their experience -saved myself $500.00
Parts Used:
Defrost Thermostat
  • Patrick from Punta Gorda, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge wouldn't cool
3 weeks After changing the defrost heater, i had to change the thermostat, part was suppose to come with wire connectors and everything needed, it didn't. Cut two wires to old thermostst, strip about a 1/4 inch of insulation and crimp new wires on part together. cover with heat shrink and heat with lighter until sealed.
Parts Used:
Defrost Thermostat
  • Jeffrey from South Fork, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
warm, refrigerator/freezer,frozen up
verify the heating element was o.k., found the top of the thermostat popped off,it had water in it,probably froze and came apart,cut the wires to the old thermostat and splice the new ones together,put the cover back on and verify operation
Parts Used:
Defrost Thermostat
  • richard from cleburne, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer and Fridge barley cold
I took off the back panel in the freezer. Located the wires going to the old thermostat, cut them with wire cutters. I then spliced the matching wires together and attached the part to the coil tube (There is a little clip on the part, be sure to do this because I forgot and had to go back and do this again!!!).
Parts Used:
Defrost Thermostat
  • Randall from Stone Mountain, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The freezer temperature was increasing.
i took out back frame and cleared off the ice on the metal condenser. I cut wires from old thermostat and removed it. Stripped new wires and attached to the wires in the frig. We taped it with electrical tape and put it back and closed it up. it works beautifully! We watched a video on youtube and that helped a great deal!
Parts Used:
Defrost Thermostat
  • Susan from Sea Cliff, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge kept getting warmer and frost started building up in Freezer
I ordered the part but my husband had to work out of town for a week. The fridge kept getting warmer, so when the part came I just watched the video on the internet, (bit the bullet) and did the repair just as I saw it done on the video. It was simple and exactly the same as the video. It took a little longer for me because there was a lot of ice built up on the coils, so I used my hair dryer to melt the ice. My refridgerator is working great now.
Parts Used:
Defrost Thermostat
  • Linda from Montrose, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Wrench set
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The freezer would freez up and stopp cooloing the entire unit
I took the ice maker out then the panels that closes in the evaporator coil. Disconnected the defrost censer and tested it with an ice bath. The censer did not close the circuit. So it's bad. I got the parts .(Very fast I might add. The PartSelect team did a great job of getting it to me). I the stripped the wires and spliced the like colors back together and tested the censer again with an ice bath. It closed this time. I started the frig and have not heard anything from the client. In this case "No news is good news". Thanks PartSelect
Parts Used:
Defrost Thermostat
  • Walt from Freeport, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GTG25DBSARWW