Stripped Front Leveling Roller & Screw
Raised side of fridge enough to get 1/4" ratchet with 1/4" socket under roller wheel assy. Removed three hex-head screws to separate damaged wheel assy from fridge frame. From panel below fridge compartment, backed-out stripped leveling screw. Mounted new roller assy and then threaded in new leveling screw from front. Lowered fridge and adjusted leveling screw for proper height. Suggest putting a 2x4 under fridge for safety when hands are under unit.
I visually inspected the compressor and narrowed down the source of the noise to the freezer area. Then I removed the doors and the screws securing the divider panel. Next I removed the bottom panel of the freezer, the styrofoam insullation panel and the evaporator motor. The motor is mounted between two grommets. I replaced the grommet facing the fan blades. The aluminum reflector below the styrofoam insulation panel had also come loose. I reattached it and reassembled the refrigerator in reverse order. The noise is gone!
remove back panel inside fridge freezer side, everything frosted, unplug and used a hair dryer
1. Took out defrost heater and the bottom and tested (per this site) tested OK.
2. Then looked at the defrost thermostat, it was swollen with the top coming off. so i new it was bad 3.clipped and stripped the 2 wires, spliced in the new one with wire nuts and sealed them with silicone. All better
Removed back wall cover over coil. Defrost all ice with a hair dryer. Cut white wires and replaced Temperature Sensor. It has been working for a week and no trouble at this time. If you have this system on your GE refrigerator do this before replacing the motherboard. I must admit I was thinking that was the trouble. Motherboard was replaced after 5 years old now 5 years later my thinking is this a 5 year problem. So try the Temperature Sensor.
I replaced the three sensors, 2 in the freezer 1 in the refrigerator. This was rated as the most common problem. Did not fix the problem. I then checked the ohms on the new sensors then the old sensors they were all within .5 of each other. So I got smart and went down the list of causes on their list. I emailed partselect and asked what the parts should read. They replied with that information and it turned out to be the voltage converter on the compressor. I ordered the part on friday payed for overnight delivery and it arrived tuesday. This as you can imagine makes me angry. But the part was easy to install and my refrigerator started working right away. I would advise anyone with this problem to start at the top of the problem list use a multi meter check everything on the list and only replace part or parts that don't come up to standards. This will save time and money and hopefully fix the problem the first time as you are not switching out parts and hoping that it solves the problem.
The original fan had its blades sheared by ice build-up
The original design is poor. The evaporator fan is mounted in an upright position just below the ice-maker. A plastic grate mounts over the fan assembly to allow for air circulation. Unfortunately, random chips of ice from the ice maker can fall into the fan, causing the fan to shear its blades. Replacement of the fan blade is relatively simple (accept for having to completely unload the freezer and remove all back covers, the ice-maker auger motor assembly, and the metal evaporator cover). In order to mimimze this from reoccuring, I installed a 1/4'' mesh metal screen over the exhaust ports on the cover. Thus far, this has worked well to keep ice chips out of the evaporator fan.
took the back off and defrosted with a hairdryer. disconected the part pulled the part out cut the wires. put the other part on and instaled it. put it back together and it seems to be working just fine. thank you
Replaced Defrost Thermostat. Tricky removal of light fixture cover and evaporator cover. Light cover screw removal is not intuiitive and the eveaporator cover tabs are not easy AT ALL to remove.Once they are removed, simply 2 screw removal of rear panel.
Had to unscrew screws holding cooling coils to gain access to thermostat mounted on a coil in rear.
Simkple matter to cut wires, remove old thermostat and splice replacement back on. Found it simpler to re-mount thermostat on top coil greatly simplifying process.(Why didn't they place the original unit in this much more accesible place?) Re-attach coils to rear wall replace rear panel, light fixture cover and evaporator cover.
Refrigerator has been running fine this past week.
1 opened door 2. pryed cover off from cieling 3.cut and stripped wires on 4. sodered wires from old wires to new sensor. 5 insulated conection.6 put cover back on. This did not fix the problem it was the control moduel.
I followed the onsite video and had no problems. Shut off refrigerator, removed storage trays and bind, removed the rear panel under the light, identified the orange and pink electrical wires and cut them. Spliced the new wires of the thermostat with refrigerator wire and capped them, applied electrical tape to insure no moister makes contact with wires. Replaced rear panel and storage racks and bind. Plugged in the refrigerator and it is operations like new. I was about to purchase a new refrigerator for $ 1,300.00 and the thermostat costed $ 13.00. What a Christmas present!
I watched the video online and it said there were three sensors in the refrigerator, two in the freezer and one in the refrigerator. I only ordered one sensor and was going to try the one in the refrigerator first. He said the upper one in the freezer is the most difficult, but is usually the problem. So, I replaced the upper sensor and tried restarting the unit. Everything went well and it fixed the problem.
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of freezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.