Refrigerator quit running
I located the part that was the culprit as it had buzzed very much before quitting. This is an easy removal as the part is in a two prong jack and just needs to be carefully removed with the new part inserted back in the jack provided. The refrigerator works fine now, but the run capacitor will still buzz on start up of the compressor. I do hope this is normal in this model? anyway it runs fine mow. Thank you.
Remove back panel inside Freezer compartment remove 2 screws that hold (small) fan motor. Unplug electric motor supply and install new motor in reverse order
First I remove protection cover,then removed the elbow pressing in on the gray coupling housing at each end of the elbow.Mark each piece of water hose before removing the elbow with marker(black)it helps when replacing new elbow.The new elbow slides on each end of water hose ,connect the end to the hose coming out of the door first. Replace protection cover. No more leak.
The freezer coil was frosting up blocking airflow to refrigerator side
I first unplugged the refirgerator. Note the time because the refrigerator should be unplugged at least 30 minutes before plugging back in (see end for why). A trouble light is necessary to see adequately. I removed the shelves and draws and put food in a picnic cooler. I took off the lower panel in the back of the freezer, and defrosted the coils with a hair dryer. I unplugged the wires to the defroster, and then the screw holding the coil to the back of the freezer side. I lifted up on the coil unit to clear the blade that inserts into the drain. I removed the bands on the top of the coil that hold the heating unit in place. I tilted the bottom out when there was clearance, and pulled the defrosting unit down and out. I replaced the new one, and reversed the procedure, and then plugged the wires back into the new defroster unit. The bands on the top should be secured before putting the coil back in place, as well as the foam spacers on top of coil, put the two wires back in the plastic clip that keeps them away from the fan and pipes. Replace lower freezer cover panel and screws. Put shelves and food back in. If at least 30 minutes have passed, plug the refrigerator back in. If you don't wait that long, their will still be pressure in the compressor and it will not start to cool properly right away. It works perfectly now. TIP: check the end of the drain hose periodically by taking off the lower back cover and pull th hose out - not hard to do. Mine plugged from dust and lint build up backing up into the end of the hose so water didn't drain out, and ice built up causing the defroster coil to burn out. I cut a little off the hose so the water level would not rise up into the hose, but the hose would still stay in place in the plastic holder.
frezer not staying cold enough to freze newly added product
took the shelves out, unscrewed the rear panel,unpluged the thermistat and uncliped it from the line.Replaced with new thermistat in the reverse order. Before turning the unit back on,allowed the coils to defrost.All of the process was shown in your vidio that I was able to view while ordering the part. Thank you
got replacement ice container with ice crusher and dispenser in the door. removed broken one and slid in the new one like a drawer and started crushing ice right away!!
There was a hole in the plastic bin where ice fell through to the freezer.
I removed the screws that held the the ice dispencer from the bin. I than removed three screws from the bottom of the bin. I put the new plastic piece on the end of the spiral piece that pushes the ice. I inserted the spiral piece back into the hole. I than screwed the ice dispencer to the bin and re-inserted it back in the refrigerator. It took me about 5 to 10 minutes. It's really easy!
The ice would not come out of the front door. The flap between the door and the ice would not open.
Popped off the front access panel. Removed the heat motor and repalced with the new one. It is fixed and working great. Partselect Delivered the part the day after I ordered it. Thanks!!
Installation was completed by following the online Parts diagram. Had to completely remove all parts, including the blades in ice crusher, and re-assemble. Glad the online diagram was clear and easy to read.
I replaced the solenoid first because the ice maker was not getting water. After replacing the solenoid valve, I waited about 1/2 an hour, still no water. So, I ordered a replacement ice maker. I then installed the replacement ice maker, waited a 1/2 an hour, still no water. Then, I waited overnight. Yeah, ice! WORD OF ADVICE. WAIT OVERNIGHT TO SEE IF THE ICE MAKER CREATES ICE. Not sure how long a cycle takes, but it's longer than you would think. Hope your installation is a success!
Pull out the unit from the wall, Unplugged the frig, removed the lower cover panel. Remove 2 screws holding the water valve from the unit, then removed the 2 connectors that turn on the relays. Connected the connectors to the new valve, then replaced inside of unit and replaced the lower back panel cover, plugged it back in, then tested the water flow at the spout, and waitied for the ice maker to kick in. Worked perfectly.
The site offers a video for this part which worked perfectly. In addition to replacing the part, since the cardboard panel was off, we also cleaned all the dust off of the coils which someone recommended to do annually.