The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Removed top hinge and electrical connector (freezer door has ice and water dispensers) then had to turn off water supply to unit and disconnect the hose to the door and remove the spring protector from the hose -- this required removal of the compression fittings in the water line so spring would come off of the tube. Then removed bottom hinge from the door and used saw to remove the rivet that had held the cam to the hinge, used a nut and bolt to attach new cam. Put other cam (used two) in the hinge and replaced lower hinge unit on the door. Then reattached both hinges to the refrigerator and lined up the door put the spring protector and compression fittings back on plastic tubing and reconnected the water supply and electric fitting, turned on water to unit and prayed there were no leaks. Prayer was answered, the water dispenser worked properly and the ice maker filled with water so I then replaced the hinge cover on top of the unit and the grill at the bottom and had a pepsi. A few years ago I had replaced the cams on the other door which had no water/electic connections and was a much simpler job.
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
Broken water line near solonoid to feed drinking water
bought an push in, in line connector and a new 5/16 plastic hose. I just replaces 2 feet of plastic hose from the selonid up an splices the hose using the connector. Worked perfect.
The comments from customers experiences gave me the confidence that the defrost timer was the problem since the compressor was still working and it went just as they all said, four 1/4' hex head screws and I had access to the old timer, unplugged the old ,plugged in the new and put the four screws back in. Nothing happened so after a while I looked a bit harder at the accessable part of the timer after intallation and saw what looked like a dial. I turned the dialclockwise and immediatly the compressor turned on. I have not found any information as to how much or little to turn this dial which obviously is an adjustable cycle setting so I just turned it all the way, so far everything is working alright.
Condensor Fan not turning. I thought it would be an easy fix. I thought I could pull off the shroud and fan assy - no joy. Too many copper pipes and lots of tubing in the way. It took 90 minutes to remove and 30 minutes to install. The BIG hint here is to loosen the shoud, pull it back as far as you can and then remove the nut that holds the fan blade in place. THEN you can remove the motor. Get the new motor back into the shroud, get the blade back on and then tighten the shroud back up.
Turned off the refridgerator. Took everything out of the freezer compartment & put into ice chest with pleanty of ice on top. Removed 2 screws holding the ice maker in place & placed ice maker aside. Removed shelf. Removed one screw on back plate, pushed up on the holding tabs at the top of the back plate & removed the back plate. Removed 3 screws holding the motor bracket in place along with the 3 wires. Installed new motor & used the wire extensions provided due to the electrical connections on the new motor being on the opposite side. Had to bend one wire tab down to clear the motor bracket. Turned refridgerator back on to ensure correct rotation on the fan. Reinstalled back plate & ice maker & shelf. Waited 30 minutes before putting food items back in freezer compartment.
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Water Leak From The Ice Make - Water All Over The Frig
Replace the old water valve (wr57x11) with the new one (wr57x10051: make sure you unplug the 110 ac power . And close the water come to the refrig. First 1. Open the paper panel on the back with screw driver. 2 Use a small adj. Wrench to take the old valve of. 3. Label the connector and its terminals in a proper number to identify their connector. 4. Unscrew 2 water hoses - one to the drinking one to the ice maker. They are in diff. Sizes - make sure to mark where the hoses connected in case you need to use it again. 5. Cut of the thread section on the hose end - you do not need thread any more on the new water valve. 6. Make sure the new valve is in the same position as the old one. Then plug the water hoses to the valve - and connector terminals. There are 2 new terminal adapter in your new package. These new adapter will be fit to the old hardness for connecting to the new valve. 7. Secure the valve onto the refig frame then plug in the water hose to make sure no leak at the valve. The new valve has new type of self-lock plug ( not thread ) to the 2 water hoses. Make sure to press hard so the hoses are fit in to these new water . Valves. Turn on the water and power on on the refrig. That's all. Very simple save $300 for hiring the service man. Good luck to all.
Plastic water line gets brittle from compersor heat over time and eventually brakes. I tried to fix with 5/16 line from a locel hardware store but outter diameter was slightly smaller so connection to valve leaked. This OEM part fit perfect. I cut the line beyond the brake and connected it with the tube union part, Easy fix. Everything works fine with no leaks
Simple job, empty the door shelves, remove top hinge, lift door off bottom hinge, remove bottom hing. The reassembly is the reverse, with a little cleaning along the way and a little white lithium grease on the hinge pins and cams.