Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Freezer would not defrost correctly
Took panel off back of inside of freezer section, took off old sensor from the evaporator, spliced new sensor into the existing wires, waterproofed spliced connections, snapped sensor back onto evaporator, then put panel back on the inside of the freezer. Really, it took only 10 minutes to fix. Now refrigerator defrosts like it used to, and temps have settled in at specified temps.
I took the four screws out of the ice basket and removed the plastic cup pieces. I then lifted the scress shaft up and put the new cup in. You have pull up very hard on the screw shaft and use two thin flat metal puddy knives to disingage the two plactic stays on each side of the shaft holder. The plactic housing around the screw shaft did not brake, however. I then put the screw shaft and the cup drive in place quite easily. Works fine.
I have unlock the black panel. With a screw driver I have removed 2 screws and removed 3 conectors from circuit board. So, I had access to solenoid set. From this point on was intuitive. Very easy.
I recomend these parts be replaced once time for each two years.
Frig and freezer were defrosting and refreezing other than normal. Home warranty contractor told me ice maker was faulty. Purchased new ice maker. Unplugged frig, loosened 2 screws with nut driver. unplugged old ice maker, lifted old ice maker out. Took old fill cup off old unit and put on new unit since new fill cup was a different size. Swapped ice maker insert from old to new unit. Plugged in new ice maker, slid over the 2 screws, tightened, and plugged in frig power. New ice maker works fine but still have defrosting and refreezing problem. Figure old ice maker probably works just fine. New contractor still trying to solve problem. Have had problems with this GE Monagram keeping proper temps since it was new in 2005, don't recommend it.
ice despenser door would stick open and frost up to the point of of ice not coming out
after finding the video describing the same problem, i gave it a shot. Major problem was figuring out how to take outside trim off of the ice/water dispenser. Everything i tried did not work like the videos i had seen. Looking thru some of the posted blogs i found another way to get behind the control panel without even taking off the trim piece. i pressed a 1/8th allen wrench into the two outer holes on the bottom of the control panel which released the panel to pull out from the bottom. after that it was simple to release the three plugs from the circuit board and remove the control panel. 4 phi lips screws later the ice chute comes straight out revealing the flapper door which is held in by 2 more screws. once that assembly is out the solenoid is held by three more screws. there was nothing difficult at all about this repair once the secret was out about the first step about the three holes (use only the outer two) in the bottom of the control panel
Noticed the problem in November 2009. Replaced Hi Limit Sesor for Defrost thinking it was the freezor temperature sensor. Did not fix the problem. Replaced Motherboard. Did not fix the problem. Called Sears Repair. They mis-diagnosed the problem and told me it was the sealed system. I doubted them and sent them home. Replaced the correct freezer temperature sensor that connects to the motherboard. FIXED. Removed a panel, cut two wires, soldered and insulated two wries, reinstalled panel.
Pulled Ice bin out and emptied ice out of bin. Removed 4 screws holding bin to frame and seperate bin from frame. Takeoff or loosen dispenser arm that has 1 screw holding it. On the sides in the front I pushed tabs in and pulled up on front auger/chip assembly area using two screwdrivers to hold tabs in. Pulling assembly up took a little pressure by hiting down on main ice bin to disengage and watching to see that tabs were also disengaged at same time. After that it was take c-clip off loosen nut and disassemble. You might want to draw a diagram as to how everything was in place or take a picture with your camera phone to make it alot easier for you to remember how everything went. Remove and Replace parts and assemble in reverse.Once you start to do it you'll see how it goes so easy, hopefully I didn't miss to many steps but if I did You'll see what needs to be done to go to the next step.
Disconnect Refrigerator by unplugging from wall socket. Removed back access panel. Shutdown water supply to refrigerator. Have a backet and towels handy to catch residual water in lines. Unscrewed water valve assy. Push water line connectors inwards and remove plastic tubing. Using a wrench (or Adjustable wrench) remove incoming water supply line. Attach incoming water hose to new valve assy and push other two lines in valves. transfer the electrical conections.
Nutdriver, Screw drivers, Wrench (Adjustable), Wrench set
29 of 32 peoplefound this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker wouldn't dispense ice
ice tray slides right out. 4 philips to remove the bottom, 1 to remove the arm that controls the mode (regular vs. crushed). It just slips into a hole on a wheel at the dispenser end - the same end has two tabs you push in and slide up/out the coil screw that rotates and drives ice out. Once one end is out, it slips out, replace the cup, reverse. This is the 2nd time I've ordered from PartsSelect, both times the part came in just a couple of days, easy navigation on the site, plenty of security validation, etc.
Actually this was a two part repair of which I purchased both parts. The micro switch Pt # PS296176 and also a double outlet water valve Pt # PS304374 from Parts Select as well.
The difficult part was accessing the area to get to the micro switch.
The trim had to be removed, then the cover.
Then one unplugs the board and removed the face plate which also contains the micro switch.
Once removed the two electrical terminals had to be disconnected, the micro switch installed and terminal reconnected.
Then reverse the removal procedure.
Then on to the double outlet replacement.
Suggest watching the installation video for the replacement although it was really a straight forward repair.
Two things to remember.
1. Unplug the fridge
2. Shut off the water to the dispenser
Overall it was not bad at all.
This was my first attempt at refrigerator repair and it went well.
Replacing servo was not hard, but did not solve problem. Searched some more and the cure is to remove the light bulb from the dispenser. Seems that old bulbs draw too much current and cause the control panel to fail in sending signal to icemaker motor. Removing the bulb cured this fault and the control panel worked fine.
Solenoid had become rusted/crank door wouldn't close
First, had to use punch tool to pop out electronic face panel. Face unit still connnect via wires. Use painters tape to hold against refrig. Next, Remove ice/water dispenser and also tape to door. This will give you access to solenoid. Remove the 3 screws holding it in place and unplug fsolenoid from Face Panel. Screw new solenoid and place and connnect to Panel. Goood idea is to unplug regrig. while doing this and put a little WD-30 on shaft of solenoid. May want to order new screws, could be rusty, that hold solenoid in place. Sounds a bit complicated but not that bad a job. You'll save over$100 over GE's service.
After having replaced the main control board and three thermistors, the fridge was still having difficulting getting cold enough - it wouldn't get colder than 15F / 42 F. Uniform frost on the evaporator coil ruled out a sealed system leak, so the remaining culprits were the either the evaporator fan motor or the compressor.
I read that a failed control board is almost always the fault of a bad evaporator fan motor, so this item was the most likely suspect.
To get to the evaporator fan motor, I had to remove, in this order:
1) Icemaker 2) Auger motor and brackets 3) Icemaker bracket 4) Freezer lights and bulb sockets 5) Evaporator panel 6) Evaporator plenum cover 7) Evaporator fan motor bracket
The greatest difficulty lay in swapping the new fan motor harness. Two pins in the harness connector were used for the evaporator thermistor.
I had to carefully cut through the old connector (using a Dremel) to extract the crimped-on pins for the thermistor, then reuse them on the new connector.
The fridge is now maintaining -5 F / 35 F in the freezer / fresh food sections.
Water is not coming from front door dispenser, but ice maker works well
On one severe winter cold night my fridge dispenser door stopped water supply, but ice maker was working. First I disconnected power supply to the fridge then turned off main water supply from the wall to fridge and with wrench set disconnected water supply pipe from wall to fridge while disconnecting the pipe make sure to collect the water from the both end pipes. Then removed the cardboard from the back side of the fridge. I disconnected the blue element (dispenser water) the red element (ice maker). [DOUBLE OUTLET WATER VALVE]. If you would try to pull the pipes white (dispenser water) and black (ice maker) you woudn't succeed because once the the white and black pipes are insereted into the water valve those pipes are clamped tightly in the valve. So I cut off those pipes and removed the old water valve, then I conncected the new water valve first conncected those white and blue elements and inserted the white and black pipes pushed in closed with round plactic caps comes with new one.I reconncected the main water supply pipes from wall to the frige and turned on the water supply from wall and plugged the power supply. First surpisingly I doubted it will work, actullay the water dispnser did'nt work immediately I have to wait 2 to 3 hours of time, in the mean time I checked the pipe connections from the bottom of the front left side door ( if you open the two doors bottom you can see the plastic cover it can be removed by pulling towards and pushing in you can close it back into normal position) which water supply pipe comes through the bottom of the door to water dispenser. I disconnected the connector and pusheed the dispensor several times to flushout any leaky water or air then I reconnected the pipes to the connector. I pushed the dispenser with a cup to dispenser, it started working as it is normally. While I was working my 7 years old son helped me as he always eager to learn and explore things.