Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
defective light switch
inserted a knife between the switch and the plastic interior in order to pop the switch out. then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
The repair was super easy. It took all of 10 seconds. From ordering the part to repair, I would use part select 100%! Excellent company with excellent parts. Thank you!
There was no water in the icemaker tray to freeze into ice cubes
Took off the rear cardboard cover, unscrewed the old valve, checked to see if there was enough tubing to fit if I cut the tubing. removed the 2 electric connectors, Cut the tubing 3, installed the 2 electric plugs, inserted the 3 tubes, mounted the new valve, replaced the cardboard cover. I checked for leaks, and very soon heard the valve filling the icemaker tray, and soon, Ice cubes again.
Opening up the Evaporator Fan section was a quick and easy job. After opening, I checked and removed the fan and looked at the grommet. The grommet on the fan was tight and secure and I could no longer hear the noise. I closed the opening. Something I had done while checking the fan grommet must have solved the problem. I have not hear the noise again!
The door would not stay closed after it was installed. It was as if there were no magnets in the gasket.
We used the hair blow dryer to soften the gasket after being in the package. We laid it on our bed and made the gasket straight with the heat of the blow dryer. Then we began to install the gasket and once we installed it, the door would not stay closed.
The light rocker switch wasnt working. I found the part on the web site. It was so easy. I used a screw driver to pop out the old one and pop the new one in. It took 5 min. Thanks!!!
First I removed the screw holding the ice door shaft (at the rear of the ice container). Removed clip of which the screw was holding in place (no need to remove the clip from the shaft). Then I removed the front cover screws, separated front cover from ice container. Door shaft is removed with front cover assembly, no need to remove anything else from front cover. Pulled out auger shaft, removed circlip (snap ring) and washer from front of shaft. Used an adjustable wrench to remove plastic nut from front end of shaft. CAUTION - the plastic nut is reverse thread, make sure to turn it clockwise to loosen and remove. Pulled off broken auger then reassembled with new auger in the reverse order as previously described.