Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
ref/freezer would not maintain proper temp. Ran all the time or would not come on once it quit running. Freezer would get too warm or ref. would get too cold and freeze contents.
1. Unplug, remove control knob from both temp control sliders, remove upper light bulb and light shield from refrigerator compartment. 2. Remove screw holding top of bracket control mod in place. 3. Lift bottom tab from slot and remove control mod from ref compartment. 3. Unplug temperature control and defrost timer and replace. (Each are held in place with two screws.) 4. Replace control mod. This part took me the longest because the space between the top of the control mod and the top of the ref. compartment is very small and replacing the nut was difficult. Use a nut driver with a long shaft. 5. Use screw driver to turn control button of defrost timer to start cycle. 6. Replace bulb cover and light bulb. 7. Set temp control to initial setting. 8. Have a Margarita and celebrate. It's been over a week and the refrigerator/freezer is working perfectly.
This is a sibe-by-side refrigerator/freezer that needed a new lower hinge set for the fridge door.
First I removed everything from inside the fridge door, closed it, then loosened the top hinge bolts with an 8mm socket on a 1/4-inch ratchet. Using an 8mm nutdriver, I removed one bolt and loosed the other just far enough to be able to lift the hinge and swing it out of the way. (These bolts are long. The nutdriver is faster than the ratchet but you need a ratchet or a wrench to first break them loose.) Then I just lifted the door off the bottom hinge and set it aside.
The plastic lower front grill was covering the lower hinge but that grill is just held at the ends by spring clamps -- popped off easily so I could get to the hinge bolts. Again, 8mm bolts, just remove & replace hinge. I also had to replace the upper half of the door closer cam, which is screwed to the bottom of the door, being careful that the holes lined up: cam, shim, door holes.
Now the tricky part was lifitng the door back on the lower hinge. (It helps to have an assistant at the bottom to locate the hole for you.) Once the door was up, I swung the top hinge over, ran the two bolts in finger tight with my nutdriver, checked & adjusted the spacing* of the fridge door and tightened the bolts. This was all very easy! (*^_^*)
*On a side-by-side, you'll want the door to be straight up & down with a consistent gap top to bottom with the freezer door. The hinge has some slack for adjustment by positioning the door, then tightening the bolts. You'll see what I mean.
First pried off front panel, then removed 4 screws that hold dispensing unit in place, then rotated top of dispensing unit out, then pulled off electrical connector, then removed screw that holds switch in place and removed switch. Installed new switch by reversing above procedure. Only thing switch wasn't the problem. No ice problem was resolved later by replacing control printed circuit board which is located in the same area.
I removed the shelf, unscrewed the slide rails and replaced them with new ones. I replaced the shelf, put the food back in and I was done. Thanks, john bowers
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice bin had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
Refrigerator would turn off and never come back on.
First unplug the refrigerator!
Removed the top shelf of the refrigerator. Pulled off the knobs from the temp slider controls. Popped the cover off of the light and temp control section. This Hotpoint model has both thermostat and defrost timer easily accessible in the refrigerator compartment. Used a socket set driver to loosen the screws and remove the temp control section and unplugged the wire connectors. This freed the whole temp control section. On the workbench removed the old thermostat by unscrewing the screws with a socket driver. Unplugged the wires from the old thermostat then put the new one in. Then put the new one in the same holes, reconnected the wires and reassembled the everything. Then simply put this temp control box back in the original place (and reconnect the wire plugs) and put the screws back in . The hardest part is re-aligning the holes and the control levers, but this is not too bad.
Plugged it back in and so far it has been turning on and off normally. (The old thermostat contacts were oxidized so I think this was the problem).
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
The job was fairly easy. Removed 4 screws and removed panel. Disconnected cable assembly, removed 4 more screws holding heater coils. Reconnected cable assembly and replaced screws & panel. Partselect was quick to ship and would do business with them again.
Removed top hinge and electrical connector (freezer door has ice and water dispensers) then had to turn off water supply to unit and disconnect the hose to the door and remove the spring protector from the hose -- this required removal of the compression fittings in the water line so spring would come off of the tube. Then removed bottom hinge from the door and used saw to remove the rivet that had held the cam to the hinge, used a nut and bolt to attach new cam. Put other cam (used two) in the hinge and replaced lower hinge unit on the door. Then reattached both hinges to the refrigerator and lined up the door put the spring protector and compression fittings back on plastic tubing and reconnected the water supply and electric fitting, turned on water to unit and prayed there were no leaks. Prayer was answered, the water dispenser worked properly and the ice maker filled with water so I then replaced the hinge cover on top of the unit and the grill at the bottom and had a pepsi. A few years ago I had replaced the cams on the other door which had no water/electic connections and was a much simpler job.
Broken water line near solonoid to feed drinking water
bought an push in, in line connector and a new 5/16 plastic hose. I just replaces 2 feet of plastic hose from the selonid up an splices the hose using the connector. Worked perfect.
The comments from customers experiences gave me the confidence that the defrost timer was the problem since the compressor was still working and it went just as they all said, four 1/4' hex head screws and I had access to the old timer, unplugged the old ,plugged in the new and put the four screws back in. Nothing happened so after a while I looked a bit harder at the accessable part of the timer after intallation and saw what looked like a dial. I turned the dialclockwise and immediatly the compressor turned on. I have not found any information as to how much or little to turn this dial which obviously is an adjustable cycle setting so I just turned it all the way, so far everything is working alright.
Flapper not sealing. Frost buildup on inside of freezer door
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope