Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Refrigerator compartment warm
first confirm that freezer is cold. if is frozen solid it needs to be defrosted. take the freezer items out,take shelf out, bottom cover, 2 screws. then ice maker, 3 screws and unplug wires. then back panel 2 screws. In refrigerator compartment were the controllers are located, look under it you will see 1 hole, insert a flat end screw driver and turn clockwise till it stops. this action will turn on your defroster, also the compressor will stop. is the heater melting the ice? if so soak up water and clean tray, use hair dryer in drain hole to aid in the defrost, check tray under fridge and if its dry keep defrosting. it should take half an hour. now take the flat head screw driver and turn the defrost timer clock wise out of defrost mode a quarter turn or so. the compressor should come back on, soon after the fan in the freezer compartment should also come on. this steps lets you no that the defrost heater works, fan works and drain hole is clear. if its defrosted place parts back in the reverse order. if not defrosted replace heater or mother board. in refrigerator compartment were the dials are located their are 2 screws, one on the left and the other on the right side take them out, the cover will drop down, you will find wiring schematics you will need them to install defrost timer. is timer making ticking sound? if no replace timer. new timer will be different from original so follow instructions that come with it. timer is above were the hole is located. the plastic hold downs will break when you try to take them off, unplug fridge, lift timer out and remove from wire harness. the new timer has a black wire that slips over either 1 or 2 depending on color of wire on the wire harness. check schematics. some silicone adhesive will keep unit in place, ad some into the plastic shaft prior to installation, plug wire harness return wiring instruction along with new one inside of cover, plug in fridge, turn defrost timer clock wise with flat head screw driver making sure that you hold timer from above so it wont move. did compressor come on?. put all paper work inside of cover before installing cover
Internal light did not come on each time the door was opened.
After disconnecting the electricity. I followed the instructions as indicated in the "HOW TO" article on the website. I used a steel putty knife and pried the light switch out of its retaining hole. I worked the right side the most since this is the side with the retaining clip. After I removed the switch I transferred the two electrical outlets to the new switch and easily snapped it into place. Engaged the electric power and tested the switch.
Unplug appliance. Socket wrench to unscrew two screws. Module drops down. disconnected two press-on wires by prying off with screwdriver. Removed old switch. Press-fit new switch. Reconnected two wires (color coded). Screwed module back in place. Plug in appliance.
Pry old switch and pull out. Disconect two wires. Put two wires on new switch, must be inserted right and connections not loose. Put switch in, making shure wies do not come off and snap in place
Part was easy to order, delivered quickly, installation very easy. Just unplug the unit, pop out the old swich using a screwdriver, disconnect and reconnect leads and pop switch back in. Definitely recommend that you can do it too.
A very cold and brittle switch in a 17 year old fridge. Used screwdrivers to pry out with some resistance Had to cut the molded plug in half and split wires, because replacement contacts were farther apart than the original. End result, works great.
After finding water on the floor I investigated to find the leak. I Found theat the Icemaker fill tube on the back of the frig was cracked(due to someone pushing the frig back against the wall). Turned off the water supply to the icemaker. Removed the 2 screws holding the tube in place. Slid the tube out and slid the new one in. Replaced the screws and turned the water back on. Very easy, very inexpensive.
removed the 2 screws that held the panel in place, had to reach up and push on locking tabs to lower trhe front of the panel. was able to then push on the locking tab of the switch to release it. removed the wires, replaced them onto the new switch, and snapped the switch into place. the rest was reverse of the uninstall process.
Switch was not working after a repairman had fixed something else
Please bear in mind I am 65 years old & it was harder to get up & down off the floor then to change the switch. Was very easy - watched video, unplugged unit. I used the putty knife at the right front corner to work loose, when it came loose had to loose the left side a little. The unit pulled out easily. detached the wired that had a single plug with 2 prongs on it. Attached the plug, pushed new switch into place. There was no way you could place wires on wrong prong. When done, plugged refrigerator back in & checked if working. I CAN SEE THE LIGHT and the food in the freezer now. Thank you for making an easy repair.