My 13 yr grandson assisted me on this
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Plastic water line gets brittle from compersor heat over time and eventually brakes. I tried to fix with 5/16 line from a locel hardware store but outter diameter was slightly smaller so connection to valve leaked. This OEM part fit perfect. I cut the line beyond the brake and connected it with the tube union part, Easy fix. Everything works fine with no leaks
Simple job, empty the door shelves, remove top hinge, lift door off bottom hinge, remove bottom hing. The reassembly is the reverse, with a little cleaning along the way and a little white lithium grease on the hinge pins and cams.
Moved all items from door storage into refrigerator shelves. Removed top hinge cover held by single screw and top hinge plate held by two bolts. Lifted up door to clear bottom hinge pin and removed door. Covered open front of refrigerator with plastic wrap to keep cold in refrigerator with door removed. Laid door on kitchen counter top and removed bottom hinge assembly held on by two bolts. Replaced upper cam located on bottom of door and screwed the hinge assembly back on to bottom of door (helps to keep the three plates in same sequence and note the position of cam). Drilled out the rivet that holds the lower cam to the bottom hinge pin. Removed old lower cam and and replaced with new cam and secured to lower hinge assembly with pan head screw and nut (instead of rivet). Replaced door back onto lower hinge pin and secured upper hinge pin with original bolts. Placed cover on upper hinge assembly and secured with original screw. Removed plastic wrap from front of refrigerator and moved the items that originally were stored in the door back to provide weight needed for door to close properly. All done and the door works like new, and all in less than 45 minutes. Would have been a more difficult job without the pioneering of people on this site. Thanks to all!
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
After figuring out how to remove the old broken clip, replacement was easy. Had to use a small putty knife to open the release on the bottom underside of the clip(between the clip & the refrig) . By looking at the replacement piece it was easy to figure out.
The cam broke apart and the pieces were on the floor. The door did not close automatically. This was on the freezer side.
I used the same steps as described in other descriptions listed here. Since I was changing the hinge assembly on the freezer side the difference I discovered was that there was a nylon water hose inside the hinge assembly that I did not at first know how to remove. I finally called a repairman I happened to know and following his instruction simply snapped the hose loose where there was a connector and placed a cloth under it to catch the moisture that drained. Having done that, the rest of the assembly went just the same way as the other instructions listed here said that it would. Door now functions like new.
Get 2 "door closing cams" yep. Same as some others here. Found some black plastic pieces on the floor, when door wasn't closing right. I took the door off by taking off the top bracket. Very easy. Bottom bracket has the broken cam riveted to it. Need hacksaw to get this off then punch it through with hammer and a screwdriver. This is the only part that took a little while. Replace the closing cam and find a small nut & bolt or screw to replace the rivet you just sawed in half. Replace the closing cam that is on the bottom the the door as well. Even if yours isn't broken. Replace it anyway. Put door back on and done. Not a diffucult project if you know about the rivet and needing 2 closing cams beforehand. Good luck
Moving the refrigerator into my new (very old) house we had to remove the doors which resulted in a crimped hose and union
Remove lower front panel, disconnect damaged union from water hose under freezer door, replace with new union, tighten and reattach front panel. No more water coming from under the unit. Ice maker and dispenser features returned to working order!
Removed the top hinge with a socket and lifted the door off. Removed the bottom hinge from the refrigerator with same sized socket. Used a Dermel to cut out the old rivet holding the old mangled cam. Attached the new cam with a screw, washers and nut. Reattached bottom hinge to the refrigerator. Removed the bracket holding the second cam on the bottom of the door. Replaced the shim and cam. Reinstalled the door. No problems. Just don't make the same mistake I made. You need two cams. They interlock and work together to close the door automatically. The cams are identical. They are just off set by 90 degrees when the door is closed.
Take the back panel off inside of freezer side. Cut the wires off old Defrost Thermostat and strip the ends. Attach the wires of the new one and tighten with wire nuts. Put back panel back on.
It took me about 15 minutes to complete the repair, 1st I emptied the ice maker, then I removed 4 screws from the rear of the ice maker tray and took the plastic piece off of the auger. I reversed the steps and put it back together.