Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Freezer drawer light switch failure.
Disconnect plug from wall. Insert putty knife between light switch.and trim panel , apply pressure to depress plastic spring holding switch in place. Apply a slight twist too putty knife releasing switch from trim piece. This wil expose plug connected to switch. Disconnect plug from switch. Connect new switch to plug. Insert switch into trim. Plug refrigerator into wall socket.
I ordered the filters that were needed and received the wrong items. After reordering and then receiving the proper items the installation went very well.
Water was leaking when ice maker or water dispenser was being used.
Looked for the same repair on line by model number. I found it, watched the repair, then used those instructions to complete the repair on my refrigerator. The disassembly and reassembly took longer than actually replacing the part. It now works beautifully with NO leaks.
Everything went as planned except the cold temperature (freezer door switch located inside freezer) made deflection of the switch locking tab difficult to remove. Letting the switch warm up was not an option.
Refer lights not working, there are two lights and neither worked. Decided the switch was the problem.
The switch fix but did not fix the problem. I assumed the wires go on the same way as on the old switch. Is it possible if one light Burns out, the other will not work either?
Small water leak from cracked fitting leading into water reservoir fill valve.
Remove some shelving and have a towel handy. Opened water filter door to expose two 1/4” screws. Removed 2 screws. Placed my hands firmly on upper panel and gently pulled/tugged panel forward and slightly down. Disconnected roof lighting clip. Removed panel from frig. Disconnected both ends from solenoid fill valves by pressing in the colored locking piece to release tubing while pulling tube out. Cut zip ties and removed old leaking reservoir. I also removed the straight reservoir seeing as the part I replace was redesigned and the other one was not needed. Put new zip ties in place. Slid the new part into position and pressed the ends into the solenoid valves. You do not need to press in colored locking pieces, they will self lock. Secured with zip ties. Grabbed a container and filled it up with water through the door to fill and purge and check for leaks. Reconnect light clip, reinstalled top liner and snapped into place. Put screws in. Closed filter door. Took about 15 minutes. I did watch a you tube video prior to attempting this repair myself.
We removed the old switch, unplugged it, plugged the new one in and it was easy to do. But when we tried to put the switch back in we had a very hard time doing it. Eventually got it in, but if it had not been for the difficulty we had getting the new switch to snap in to place, it would have taken under 5 minutes.
Once I got a part that wasn't broken in transit (took them sending it 3 times for that to happen), it was a breeze. Remove old drawer, take tracks off old drawer and place on new drawer. Put new drawer in fridge.