Broken ring assembly-would not rotate
It took longer to figure out the part # than it did to fix. I took out the dish, pulled out the old assebly, slid the new one in and I was finished.
Parts Used:
Rotating Ring Guide
  • Joseph from Riverview, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Stem on botom of rotating ring broke
Inserted new piece into the hole in base. Placed on the glass top. Piece of cake!
Parts Used:
Rotating Ring Guide
  • Kim from Norwalk, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Try to heat food and fuse would blow.
Went on Youtube and pulled up how to fix a microwave.
Parts Used:
CAPACITOR HIGH VOLTAGE
  • bart from new sarpy, LA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
7 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave starts as soon as the door is closed
I replaced the door key, it was broken on the side so it was not touching the sensor for shutdown. Replaced the door key and the backframe keep the microwave like brand new
Parts Used:
CHOKE COVER ALL LATCH ALL
  • Mathew from Houston, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
stem on bottom of guide cracked and became too loose to drive turntable
It took quite a bit longer to decide which one of the roller guides in the selection was the right one, than to install the new one. Got it right though, works great
Parts Used:
Turntable Roller Guide
  • Gregory from Bellevue, IA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
suddenly stopped working while in use
i unplugged the unit,unscrewed the outer shell so that all the wiring and internal components were visible.starting at the first of three micro switches i removed the slip on terminals installed the alligator clips too the wires so the switch would now be bypassed.i made sure the wires and clips were not touching anything plugged unit in and it worked.i then installed the new switch and closed up the outer shell
Parts Used:
Micro Switch
  • Kevin from Colonia, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Items were not getting heated up in the microwave,
Easy, and the microwave still doesn't work.
Parts Used:
Switch,Micro Micro Switch
  • Kenneth from CRYSTAL LAKE, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Install ice maker
Followed video instructions
Parts Used:
Rotating Ring Guide
  • Hildy from ELK GROVE, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replacement of Magnetron
I UNPLUGGED the microwave and removed the cover, using a phillips and a Torx screwdriver for the machine screws. I set these screws aside, so as not to confuse them with the later encountered screws. I photographed the magnetron to assure proper placement of the 6 phillips machine screws involved in reassembly (marking the the locations on the old magnetron would do as well. I marked the old magnetron "old", to avoid later confusion. I removed the two screws holding the shields to the magnetron. I removed 3 of the 4 screws holding the magnetron to the microwave, leaving one of the top screws. I held the magnetron securely and removed the last screw, pulling out a the part of the magnetron that penetrated the microwave. I installed the new magnetron in reverse order. One problem I encountered was locating one of the six screws, which had been pulled into the old magnetron by magnetism.
Parts Used:
Magnetron
  • Benjamin from Anchorage, AK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Turntable not turning.
Take off cover then the bottom. Transformer is on the bottom plate and wires won't let it come all the way off, too many wires to pull off so will have to position the bottom plate so you can get to the motor. Remove 1 screw on motor and remove motor. Install new motor connect wires replace bottom plate, replace cover. All done (hope & pray it works ok) mine worked perfect. Hope this helps.
Parts Used:
Motor, AC Synchronous
  • Virgil from Bowling Green, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No heat.
Replaced the fuse. Result; did not fix the problem.
Parts Used:
FUSE
  • Mack from Jacksonville, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace turntable motor
Unplug.Take off the external cowling from the back of the unit by removing the torx security screws. Tip: instead use a thin screwdriver blade to unscrew the torx screws, or knock out the center pins of these screws. Remove the bottom panel. The replacement motor is attached with one phillips screw, re-attach wires to motor - polarity doesn't matter. Re-assemble and you're finished.
Parts Used:
Motor, AC Synchronous
  • William from Houston, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
0 of 1 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
microwave stop turning
replaced the rotating ring
Parts Used:
Rotating Ring Guide
  • PATRICIA M from SUN CITY, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
0 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave operated but did not heat
Initial failure of over range microwave Aug 3rd. Control Panel worked but no heat. Took to local LG authoriaed local repair place. They fixed it quickly and we re-installed it. Worked fine for 2 months then had similar failure again. Agaim took to same authorized repairer. They kept unit for 3 months but finally concluded theu could not fix it and suggested we contact LG for a partial refund. When they tested the unit during re-assembly in my presence, there was a blue flash and the fuse blew. Since we had built a custom tile mural back splash around this unit, I brought it home, ordered a number of time delay fuses new capacitor and two new high voltage diodes. However, using my Fluke DMM, I checked the existing capacitor and high voltage diode and they checked OK so I just replaced the time delay fuse. The high voltage transformer leads had 2 possible ways to connect to capacitor and diode. Tried one way, plugged unit in and turned it on, and immediatly blew the fuse. Replaced the fuse and reversed the high voltage transformer connections,amd turned unit pn, and it worked perfectly. Since we had experienced several power failures during the time of the original failure, the repairer concluded that power spikes might be at fault, so I also purchased a TrippLite ISOBAR4ULTRA 3300 Joule surge protector between wall outlet and microwave, and re-installed over range. It has worked perfectly since.
Parts Used:
Fuse,Time Delay
  • Donald from Oak Ridge, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
1 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Original "Rotating Ring Guide" was broken where it goes through the bottom of the microwave.
I installed the new "Rotating Ring Guide" by setting it on the floor of the microwave with the gear socket going through the bottom of the microwave to engage the gear that turns the rotating ring guide. I then set the glass cooking tray upon it and the job was done. About 30 seconds start to finish.
Parts Used:
Rotating Ring Guide
  • TROY from DIXON, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the JE1860B