Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Fridge stopped cooling, freezer still cold... Saved $250+
First I hired a repairman to fix it who charged $125 to defrost the cooling coils then said the defrost heater would need to be replaced for $125+labor. He had the wrong part and was going to charge me >3x the price it would have been from Partselect.com too. I figure I saved a minimum of $250 vs having him do the work then charge me yet again for the right part.
Should have just done this myself from the start and saved another $125. Information about the cause, how to test and what parts would be needed were all easy to find online once I actually searched.
Unplugged fridge.
Using diagrams from PartSelect.com and other information online anb defrosted coils with hair-dryer. (This requires removing two screws in back of freezer compartment using nut-driver to remove the panels covering coils... literally a two minute job to expose coils!)
Then found and tested defrost heater. Defrost heater was fine. Per information online problem then had to be Adaptive Frost Control (ADA) circuit board.
In refrigerator compartment: 1) Removed top housing cover (covers lights, temp controls, etc.) This required removing a single screw (with nut-driver) attaching it to back and depressing two locking tabs near the back on either side. Slide it forward and down. The only tricky part of this repair is getting the locking tabs positioned correctly to get the plastic cover off. I did break the left one although it cover is still firmly in place in this case.)
2) Removed entire assembly from roof of fridge. involves loosening two large headed screws above lights and removing two hex-head screws with nut-driver above either side of temp controls. Next slide slightly to the right to disengage the two large-headed screws (or remove them completely... it seemed easier to just leave them in place.) Dropped front end of control assembly down.
3) Opened plastic box surrounding ADA and pried open locking tab holding it to wiring. Connected new board and set ADA assembly back in place.
4) Put everything back together.
Plugged fridge in and all was well. Exposed the coils again a few days later and they were not frosted up at all.
Total time to replace the ADA was about 20 minutes. Total time for everything including defrosting coils, testing, replacing parts, etc. was an hour max.
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation. I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill. Done Total time of ice maker water leak repair and fan replacement about 1 hour.
Installing the seal was fairly easy. the seal as arrived from vendor was very deformed. It came with no instructions. I was able to use a hair dryer to heat the seal and soften the rubber. While softened I pressed the seal into the frame. It slowly began to hold and take shape. Some areas where the seal had been folded in the carton took foam filler to hold into position.
Freezer was overfrosting and not defrosting. Frig. was not getting cold.
This was very easy. I removed all the shelves in the freezer compartment. I removed two nutscrews to remove the back wall. Then I removed the little radiator looking part by removing two more nutscrews. I unplugged the old thermostat assembly and installed the new one exactly like I removed it, then I reversed the procedure to put it all back together. Very easy my wife could have done it. ThANKS!! to Parts Select for the help of all the blogs I read before doing the job.
Refrigerator not cold - ice build up in freezer cabinet
Chronically faulty electronic board in upper right rear of refrigerator compartment - in Maytag and Jenn-Air. Unplug unit. Remove freezer food to ice chest. Remove baskets and shelves, ice hopper and rear lower panel to expose evaporater fins. Defrost with hair dryer and allow all moisture to dry. Then in refrigerator, remove top shelf food. Carefully remove the upper assembly cover by working the plastic down and slide forward to unhook from rear slide attachments - one on each side. This is the hard part of repair.
Then remove screws from rear wall and just behind the lamps to release the whole control assembly. In the rear right corner is the bad board. Unplug and replace with new board. Reassemble the fridge and freezer. Replug unit.
1. Removed the cardboard cover. 2. Removed the terminal block and unplugged the old motor. 3. Removed three screws that held old motor to the bracket. 4. Removed the fan blade from the old motor. 5. Installed the fan blade (after cleaning) to the new motor. 6. Crimped on new wire terminals onto the leads on the new motor. 7. Installed the new motor using the fasteners provided. 8. Plugged the new motor wires onto the proper terminals in the terminal block. 9. remounted the terminal block. 10. reinstalled the cardboard cover.
These so called factory trained techs, at least the ones that looked at my fridge don't know jack. I explained my problem, they replaced T-Stat refridge side, onother time they replaced door gasket, still not cold enough, found your website, got all the answers. Ordered and installed,defrost heater and T stat assy and adaptive defrost control. Remove shelves freezer side, remove evaporator cover 1/4" nutdriver ,defrost with hair drier, unsnap elec. connector and relaced part. The ADC, removed screws mounted on roofside was able to lower plastic panel enough to unplug the ADC, it just laid there, removed and replaced. Don't know which part was bad, but I do know that they are interconnected, at this point I din't care to defrost manually which I did for the last 7 months. Thanks for your guidance. USMC Ross
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug Remove entire back panel (both chipboard and metal fan grill) Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black) Unplug both fan wire connects from circuit block to release the fan power cable. Remove the fan mounting plate Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades Unscrew motor from brackets - note alignment of motor on brackets Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire) Connect new plug wire to the circuit block keeping wires connected to the proper terminals Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser Plug wire harness into motor and re-mount fan mount plate Reattach fan blade and secure using blade mount kit Replace back panels
Upon careful inspection, I found that the dispenser also would occasionally fail to shut off when dispensing whole or crushed ice, which led me to think that the problem was in the dispenser actuator rather than in the water solenoid or fountain switch control board. To inspect the actuator mechanism, I shut off power to the refrigerator, removed the escutcheon mounting screws, the escutcheon, the cable from the fountain switch control board, and finally the fountain bracket assembly. There was a small amount of hard water scale on the back of the actuator pad, but no groove in the plastic part of the pad that actuates the switch. I replaced the pad and switch (1 screw) and reassembled the dispenser. The dispenser no longer sticks and shuts off normally.
Removed about 6 screws. Replaced the solenoid and door kit. Replaced the screws. These parts were easy to replace. They were also super easy to identify and order from the site. I received them two days after I placed my order. Thanks partselect.com!
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
Bottom of freezer compartment was icing up/freezer was leaking water
UNPLUG YOUR FRIDGE BEFORE YOU START> First I removed the shroud covering the lights and controls in the top of the refrigerator side. This was the hardest part, actually. Their are two indentations on the back of the cover and it is really hard to pull that cover off. Anyhow, once you do that, their are two screws, one by each light bulb in the top of the fridge that need to be removed. Their are also three hex head screws that need to be removed, two in the front corners of the assembly, one in the center, back of the fridge. Take those out and the whole assembly drops down. In the back right had corner of the assembly is the adaptive defrost control. Unplug it and set it aside. Plug the new one in. Put everything back together and you are back in business.
Light switch rocker broke, disabling freezer internal light, water dispenser, and ice dispenser
Very simple. Matched female plugs with respective male color coded prong; pushed together then inserted unit in slot of freezer sidewall and rotated into position...job done.
1. Turn off fridge and Pull plug from wall. 1a. Turn OFF water supply! 2. Remove rear dust cover to gain access to water valve. 3. Mark power connectors(red/green) attached to water valve before removing them. Remove connectors. 4. Remove supply line from old valve. 5. loosen mounting screw holding old valve in place. 6. remove valve. 7. disconnect two plastic water lines from valve. 8. Cut 1/2 inch off the end of each plastic line to get to un-streached line. Make sure you have enough line to still reach valve! 9. Insert plastic lines FIRMLY into outlets of NEW VALVE to lock in place. outlets are different sizes so you can't reverse them! 10. Install new valve and tighten mounting screw. 11. replace/tighten supply line to new valve. 13. Replace dust cover! 14. Plug in, Turn on fridge. 15. Turn on water supply, bleed air out by drawing a glass of water at door, and check for leaks! All Done!