Refrigerator light would not stay on
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced. reassembled the pieces.
Removed ice bucket and discovered the auger drum was broken.
After I received the new part, I removed the front screws of the ice bucket, removed the clip that held the auger and other parts together, and then slide each part off the auger until I got to the broken drum.
Assembly was in reverse except you must pay attention where all the spacers and ice crusher bars go back into the original position. This was the most difficult step.
Works great now, crushed and cubed ice dispenses thru the door like new.
Watched video. Unplugged refrigerator and popped out switch. In plugged connector and pushed switch in place. Plugged in refrigerator and the light worked
Searched my issue on the internet then chose part select to see if bi-metal thermostat was available and it was so I ordered part which was under $30.00 incl. shipping. I then went to You Tube to watch how to replace the part but most importantly to find out where it was located and degree of difficulty. Replacement was rather simple and it fixed our 22 year old fridge. I must add that when I looked up the part it also told you what percent of the time that particular item actually fixed the problem based on others experience. I thought that was neat info. as I felt better about ordering something that may or may not fix my problem. Thank you,
Took a putty knife and Removed the old switch removed the spade terminals from the old switch and replaced them on the new switch and just pushed the new switch back in place
Brand new refrigerator with space for 6 shelves in the freezer but sold with only two. I bought two tiny shelves for $280. Yes, ridiculously expensive but what good is a freezer without shelves.
Unhooked water line from house to fridge then unbolted valve from fridge body then removed plastic water line from fridge to valve by pushing in on pex release tab then reversed process with new valve. Works like a charm. No more leakage. Wood floor is dry and Happy!
Raise side of fridge and slide 2x4 under side with broken wheel.
Remove back side cardboard access cover. About 6 dcrews need to be removed. Remove 9/16” bolt and lower compressor tray frame down to slide out wheel axel. Place wheel in slot and replace axel. Lift compressor tray and replace 9/16” bolt. Replace cardboard cover. Remove 2x4.
Pulled out the ice bin and dumpted ice in the sink. Use 1/4 inch nut driver to take out all 1/2 inch screws. Be careful to watch how door spring and holder goes. Pull assembly apart and remove alger. Plastic nut on end of alger has reverse threads, remove it and then remove broken alger drum. Replace with new drum and reassemble in reverse order.
Lower Light Socket removed and Wires capped with wire nuts
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causing the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
took the auger off and baffle replaced the baffle put every thing back together installed back to the freezer tried it out it dont work have to tear into the the motor which works the auger to see if anything else is broke.