Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
The door switch was broken so the interior light would not come on.
The instructions in the package were not helpful. They wanted me to cut the wiring harness and described where to cut based on the wire colors. My wires were not the same color! I removed the light mechanism using a combination of a screwdriver, putty knife, and plain old muscle with my fingers! The wiring harness unplugged easily and the new one inserted. It was easy to push the whole assembly back into the door. I spent more time looking for something to cut the wiring harness with (and never did find it) than the whole job actually took without needing to cut anything!
I took all items off the glass shelf. Removed the two crisper drawers. Removed the glass shelf. Installed the center rail. Replaced the two crisper drawers, the glass shelf and all items. Job done in less that 1 min. Thank you for great customer service and quick delivery.
This problem is caused by a "Duckbill" rubber grommet attached to the bottom drain tube of the freezer. This duckbill opens up during the defrost cycle and allows water to drain down the "water slide" to the evaporator pan. It doesn't take much to gum the Duckbill. Once gummed up the defrost water is trapped. The Defrost Cycle eventually makes the water flow out of the coil area to the bottom of the freezer then eventually to the floor. The repair involves unplugging the unit, removing the bottom back cover with a 1/4 nut driver, pop the power clip out to give you room, reach in and pull the duckbill grommet and the water slide, then installing this replacement drain kit. This is a p trap replacement that actually fixes the root cause of this problem. A tricky part is removing the water slide, you can see the white snap that holds the slide in place. Using a small flat blade from the top releases the snap and the unit is pulled upward rather easily. This replacement drain clip snaps in the same place. If I had to do this again it wouldn't take more than two minutes to replace. Oh, one major thing, you need to manually defrost the unit. I pulled the front door off, it is held with 4 screws ... don't remove them just loosen them and it pops off easily. I pulled the bottom tray out an it gave me room to squirt hot water with a baster into the back freezer area. Eventually everything thawed out. If I had it to do over I would have waited on connecting the tube to the evaporator pan and placed the bottom of the tube into a small sauce pan or something to collect the drain water and easily dump it into the sink. I used a sponge and that took forever. BTW, just to reiterate, use this item and not that Duck Bill for replacement, this actually fixes the root cause of this problem!
Everything went as planned except the cold temperature (freezer door switch located inside freezer) made deflection of the switch locking tab difficult to remove. Letting the switch warm up was not an option.
Refer lights not working, there are two lights and neither worked. Decided the switch was the problem.
The switch fix but did not fix the problem. I assumed the wires go on the same way as on the old switch. Is it possible if one light Burns out, the other will not work either?