Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
The Freezer defrosted and everything on the top and the bottom spoiled
i had used your web site before and i read several problems that your readers had. i went to the back of the unit, removed the bottom cover and right there the i found the run capacitor and i chaged it. since i had only ordered this part to save money i went back and ordered the Start Device which when i took it off it was completely burned. the replacement part came labeled with 2 different compressor #, so i picked the one that i had and unpluged each wire. the part may differ from the one that it's in the unit but it worked when i pluged everything back on. it also helps to take a picture of everything before removing the wires in case you have to leave it and come back later. i hope to use this refrigerator another 10 years. thank you all for your help.
All three lights are not working...lights are off but refrigerator still cooling. Also, the control box not lit up to show the temparture for freezer and refrigerator
Used a screw driver to pull old switch. Pulled one wire at a time, only two wires. After wires instlled to new switch push new one back in place where the old one was.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced. reassembled the pieces.
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
Freezer wouldn’t cool; ice buildup stopped the fan
The defrost circuit is relatively simple. Just three components and interconnecting wiring. Ensure the timer works first, then check the heater element for continuity. Lastly i jumpered around the temp switch to eliminate interconnecting wiring. You can test the switch by cooling it to see if it opens, but some do not open like the one in this particular Whirlpool until they are well below freezing so you’ll need to take that into account in your troubleshooting. Replacing the switch itself is very simple, it’s two wires and it just clips to the heat exchanger in the back of the freezer behind a metal cover.
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
inserted a knife between the switch and the plastic interior in order to pop the switch out. then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
The light rocker switch wasnt working. I found the part on the web site. It was so easy. I used a screw driver to pop out the old one and pop the new one in. It took 5 min. Thanks!!!
Door gasket not sealing allowing ice/ frost to form around and inside the door.
It was easy to take the door off by taking the two screws (located on the top of the freezer) off the top hinge and lift the door up off the bottom hinge. I took it outside and laid it on a table. Removed all the screws and took off the panel so I could remove the old gasket and clean the door and panel. The inside of the door was full of ice so we removed that and the insulation which I replaced. My wife then put the new gasket in the dryer on medium temp for about 5 minutes. We slipped the new gasket on the panel and lined it up on the door and screwed it back on the door. Then we put it back onto the freezer bottom first then replaced two screws on top hinge. Shut the door and use a blow dryer on the gasket with the door closed to make the gasket seal / conform to the door/freezer until there are no gaps between the gasket and the freezer. Note: Once the ice and water are out of the door the door doesn't weigh nearly as much as it did. Also