Refrigerator compartment warm, Freezer cold, (veggies freezing for a year or more)
First I had to determine what was wrong. Obviously the compressor was working since the freezer was cold. Digging for awhile revealed that the evaporator coils for the freezer had frozen up into a solid block of ice. Then I had to figure out why. Tested the defrost heater in place--small resistance (~3 ohms), OK. Removed and tested the timer--unsure. Removed and tested the defrost thermostat--did not turn on when plunged in ice water or frozen with canned air (turn the can upside down--be careful!, you can instantly freeze-burn your skin), bad. Chose to purchase and replace both the timer and the thermostat. Took the opportunity to THOROUGHLY clean everything, front, back, and underneath. Found the drip tray transition piping cracked at the junction and replaced it with a cut-off funnel "glued" into place and to the underside piping with the RTV Silicone. When parts arrived, tested them and confirmed that the original timer was OK and the thermostat was bad. Installed the new thermostat (and went ahead and installed the new timer). NOTE: one connector on the thermostat was not identical to the orginal equipment. Rather than cut the refrig wiring, I chose to build a jumper with the original connector on one end and a new one for the new thermostat on the other. Buttoned everything back up, re-leveled it, and let it run for 24 hours at the manufacturer's recommended "first" settings (4 and 4) without being disturbed. Seemed fine, loaded it with food, everything is great including non-frozen veggies! (I suspect the ice was forming frequently and blocking the return from the refrig compartment, which is right next to the veggie drawer.)
Following a brief power outage, it stopped producing ice. Harvester was at 6:00 with fingers frozen in ice cubes. Would make a batch if I freed the harvester and jumped the t-stat, but would quit again.
Unplugged refrigerator. Used nut driver to remove small bolt retaining wire cover on right side of ice maker. Removed wire cover, used flat head screw driver to depress side-rail clips. Ice maker slid out, unplugged. Timer module cover pops off easily. Three screws removed the timer module. Installation was reverse of removal. Had ice in less than an hour, bin was full by next morning. If you have a screw driver and know what it's for, this job should come easily.
Defrost in freezer not working, ice buildup in freezer, refrigerator not cold
Had to remove screws inside back of freezer panel, took off old thermostat. This one had a different plug on the end that wasn't compatible, so had to cut that off and wire it to the old plug end. Piece of cake. Put back panel back on and back in business. Hardest thing was getting the screws out!
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
I unplugged the fridge. Loosened the 2 top screws on the ice maker and removed the lower screw. I disconnected the wiring harness and removed the Ice maker. I removed the plastic timer cover in front. I then loosened the screws on the face of the ice maker and removed the broken ice stripper and replaced it with a new one. Re-tightened the screws on the face, installed the timer cover, plugged in the wiring harness, re-attached the ice maker. Plugged the fridge back in and walla, it was making ice in 30 minutes!
removed screws that held the ice maker in place, then removed the cover (popped off) The drive element was easy to remove, three screws and it was out. I put in the new part and reinstalled the icemaker with the three screws that hold it in place. I never call Sears for any repair. They use contract help and I have heard horror stories about those guys!
Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.
ridiculous how a tiny plastic broken part required a full motor assembly replacement. that being said, i went online, found this website and easily identified the part i needed to order. i was impressed when it arrived within a couple of days. removing the old motor and replacing the new was a piece of cake...and i am NOT mechanically inclined,
First unload the doors, and remove each door from the fridge and freezer. I placed the doors on the counter island and removed all the screws from around the perimiter with the battery drill. Lots of screws. The freezer door had some Ice accumulated in the insulation inside the door. I salvaged as much of the dry fiberglass and tossed the wet stuff. I cut some strips of fiberglass from a roll of 3.5" I had to replace the tossed insulation. The door seal installation went smoothly and the door rehanging was easy also.
I called the local Amana repair man, wanted $150 for a new ice maker because they could not get the part I needed. Found Partsselect.com and the part cost $17 with shipping. They saved me over $100. The repair was very easy too, just removed a couple of screws.
I loosened the two top screws, removed the bottom screw, lifted up on ice maker and slid it off, unplugged the wire from refrig. I transfered the wire to the new icemaker, pluged it back in, placed it on the two screws, installed lower screw, tighten top screws. Total time spent less than 15 minutes. The ice maker cost $125.00 with freight. Sears wanted $374.00
(1) Removed the three screws which attached the ice maker to the freezing compartmnet wall in refrigerator; (2) Disconnected the power to the old ice maker; (3) Removed the old ice maker from the freezing compartment of the refrigerator; (4) Took the white front cover off of the old ice maker; (5) Disconnected the wiring harness from the old ice maker; (6) Removed the "ice making-stop arm" from the old ice maker; (7) Placed the items taken from old ice maker on to the new ice maker; (8) Reconnected the new ice maker to the power; (9) Placed the new ice maker in the proper position in freezing compartment of refrigerator and replaced the three screws. JOB DONE!
Constant Compressor Short-Cycle, Actual Unit Temp Colder Than Settings
Turn freezer section control wheel off, unplug unit. Then remove all items/baskets from freezer to allow access. Use nut driver to unscrew 3 screws on control plastic housing. Drop down housing from top and unplug wires (note correct locations) from control wheel switch. Remove screws and ground wire from metal backing plate to plastic housing. Push or pry the 2 metal holdtabs down carefully to allow the 2 plastic housing tab fingers to be pushed inwards to seperate metal plate from housing. Pry control wheel off from switch arm with screwdriver. Remove switch and replace with new one. Use the reverse order of removal above to replace into freezer but use caution when replacing wheel onto switch arm and plugging in wires. Remember to carefully pry the 2 metal tabs back up to secure the plastic finger tabs in place. Job done.