Refrigerator compartment warm, Freezer cold
This is a old 2000 side by side Kenmore frig bought from sears. left Freezer side was building up ice in the back, while right side was not cool at all. The Defrost Timer was behind the light panel on top in compartment side. Easily remove unit and unscrew things. Works like a champ.
disconnect the power to the unit. remove the retainer sctrews on the mounting bracket. remove fan motor from unit. using the rerquired tools remove the fan from the old motor and install on the new one. torque the nut until all slack is out then 1/4 turn. reinstall motor assy. and reconnect power. test the system .
Shut off water and disconnected at factory joint at bottom hinge. Unplugged the electrical at the top hinge. Removed the door and installed new bottom hinge and cam assembly. Reinstalled the door and hooked water and electric back up. Part worked fine.
Cams on Hinge assembly broken, door didn't close properly
I supported door with 2* 6 scrap wood. I used cedar shingles to raise door to correct height. Using a socket wrench, I removed the hinge from the fridge and the cam assembly from the door. I installed the new hinge and cam using the shims thatwere behind the original parts. I removed the 2*6 supports and the door now works perfectly.
Refrigerator would begin to lose it's cool and we saw ice caking on the bacjk panel of the freezer section.
We had to empty the freezing section, remove the 4 screws that held the back panel and defrost the coils. Then with the diagram we got from the internet, we removed the defroster and easily installed the new one and put the back panel back on. We did find later that it was still icing over so I ordered the thermostat and we installed it today. It too was easy to install. We spliced the wires and hooked the new thermostat to the old wires and reinstalled the back panel. Hopefully this will solve the problem for us now.
Unplugged frige, removed top shelf, pulled broken fan blade off. Replaced with fan blade just purchased from PartSelect. Very simple repair. Orderd and recieved the right part.
Removed the ice maker from the freezer. Removed the switch. Tested the switch with a multimeter. Ordered a new switch. Replaced it in the box. Installed the ice maker ( 3screws and electric cord plug. It works. Details available on the internet.
Left Side Veggy Drawer Slide Rail Broken . Drawer Drops Down
Empty veggy drawer. And slide out top glass shelf of drawer. Using philips screwdriver, remove (2) screws that hold rail to side wall of fridge. Replace with new slide . Slide glass shelf back in and then veggy drawer. 15 - 20 Minutes tops to fix. Tell wife if drawer doesent shut don't force it closed! (Overload it)
When it was discovered there was a cooling problem in the refrigerator, I went to parts select web site and went through the troubleshooting section. Then I tested the defrost timer and the defrost element as directed by the web site. I then found out doing this, that is was the defrost timer. I ordered the part online and it was delivered THE NEXT DAY! I removed the bottom panel of the fridge, removed the screw holding the old timer, removed the wires, and reversed the procedure to install the new one. It has been 1 week, and everything is working great. Thank you PartSelect. I have since then recommended you to a relative who was having the same problem. Thanks again.
Lets start with the hard part: Convince wife to get a couple of her girl friends to go to a movie and see the Reader,after that visit a cafe or pub (remembered years ago the English Patient). Drove to get a six pack,removed the back panel-2 min, set a hair drier to position, had a couple beers , removed the defrost heater unit 1 min. replaced it 1 min. back panel1 min,enjoyed the rest of the afternoon,finished the beer Killed two birds with one stone Zoltan L Petho
Freezer not getting cold enough to freeze ice cream
I took the advice off of your website about the only thing that will fix the problem is change the run capacitor. I felt assured that I would have a working refrigerator freezer after making this change. I was pretty disheartened when it didn`t solve anything. I was not going to take the new part back out after the small challenge of putting it in. The next day I found out how to test the old capacitor and it was still good. I will just have to eat the $49. I did learn not to take advice from a website even if it seems like a sure thing
Refridgerator quit cooling because the defrost element had burned out and the refridgerator coils were totally covered with ice.
I defrosted freezer. Removed cover from back of freezer. Removed screws from element disconected wires. I connected wires to new element installed screws and reinstalled cover.
Removed the cover for the evaporater coils and let them defrost. Then took the old heating element out by removing two screws on the bottom element and two screws on the top element. Unplugged it and removed it from the unit. Then repeated the reverse of the procedure, installing the new unit, no wires to splice only one plug and four screws.
Instructions say run capacitor is by motor, but on this frige its in the refrigerator compartment. The capacitors looks different, one square and the other long
Ordered the icemaker replacement. unplugged the unit, followed the simple instructions and got it done in less than 30 minutes. It did take a LONG time to start making ice. But it's working now.