Door alarm going off even with the doors closed.
Pulled the instructions up on U-tube and followed them. With the socket removed 5 small bolts. Took the old switches ( I replaced both switches being I had it apart), put the new switches in and then put the 5 bolts back in.
Safety first, unplug fridge. Had to remove the top access panel, which consisted of 5 screws. Got access to the door switches. These are removed from the panel by depressing the plunger on the switch and sliding them out of the retainer. Transferred the wires over to the new switches one for one. Re-assembled. Dispenser works.
my freezer quit freezing, it would freeze for one day, thaw the next, so I went online, found PARTS SELECT, LOOKED UP MY MODEL #, come to find out it needed three parts to keep my freezer to freeze, first part was a thermistor a small PART took me longer to remove all the covers, and shelving, PULLED THE OLD OUT, CUT THE WIERS TO SIZE, AND REINSTALLED, IT WELL! THAT WASN'T ENOUGH THE FREEZER STILL DIDN'T FREEZE IT THOUT IT WAS A COOL WORMING OVEN, HAD TO INSTALL THE THERMISTOR I, SO I DID, TEN MIN, NOW I THOUGHT THAT WAS IT BECAUSE IT STAYED FROZEN FOR A WEAK, HAVE YOU EVER EATEN SOUPY ICE CREAM? SO BACK TO PARTS SELECT, THIS TIME I BOUGHT ONE MORE PT, THE RUN CAPACITOR, FIVE MIN, THAT/S ALL IT TOOK TO INSTALL. I DID NOT KNOW AT THE TIME YOU NEED THE THREE OF THEM TO RUN THE FREEZER ONE TO KEEP THE TEMP., ONE TO KEEP THE FAN RUNNING THE WAY IT SHOULD, AND THE THIRD TO MAKE SURE THE OTHER TWO KEEP RUNNING. NOW I CAN SET IT AT 4- 5 AND. FREEZE.
My light always stayed on and the icemaker stopped working.
I diagnosed the sensors in my refrigerator by holding the sensor in and seeing if I could trick the sensor it partially worked. I then used a multimeter and did an ohm test on both sensors multiple times open and closed the switch to verify which switch failed because it worked a couple times but not always. It ended up being the switch on the left hand door with 3 terminals on it and after the replacement it has worked great for weeks now no issue. best 15 dollars and 25 minutes spent!
I watched the video online and it said there were three sensors in the refrigerator, two in the freezer and one in the refrigerator. I only ordered one sensor and was going to try the one in the refrigerator first. He said the upper one in the freezer is the most difficult, but is usually the problem. So, I replaced the upper sensor and tried restarting the unit. Everything went well and it fixed the problem.
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of freezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.
This was the first time I took out the old filter on my new refrigerator and added the new one. It was a little hard getting the old one out because I was afraid to pull on it but it did come out ok and was easy to put the new one in.
I followed the directions included with the water filter and it was simple. The only problem I had was not being strong enough to easily remove the old filter. I did accomplish that after a few tries and the rest is history.
I asked two strong male neighbors to do the work and told them how to do it. Follow the simple directions on the box. You can Google it, but it will tell you the same directions.
Totally followed the instructions of the video that came with the sensor. Unplugged the the fridge, defrosted the freezer. Cut off the main sensor that usually is the one that goes out. Installed the the new sensor with new wire terminals, crimped them and covered with electrical tape. Fridge works like a charm. Partsselect is excellent. Saved me a few hundred dollars versus having a GE Tech come and do it.
The control board generated clicking noise. Temperature display wrong values.
On the internet forum I read that if the control board needs to be changed , do the same for the Run Capacitor/relay. The Ge profile refrigerator was 15 years old. First I disconnect the power cord, I removed the control board at the back of the fridge, replaced it with a new one and did the same for the run capacitor. Plugged the power cord back and it works fine. GE repair service did not want to come to do it. DIY is fine.