Refridgerator not cold becasue coils encased in ice
There is already a lot of good advice on this web site and others on how to diagnose and do this repair. I'll add a few additional comments that might be helpful.
I wanted to confirm that my old thermostat was in fact bad. I did this by disconnecting the two connectors and connecting them to each other to bypass the thermostat. This is like having the thermostat always closed. With the back panel still open so I could see the frozen coils I plugged the fridge back in and turned the defrost timer knob with a screwdriver to get to a defrost cycle. I could then see the heater element slowly melting the ice. This is of course not a safe way to operate the fridge. Over time this would get too hot and damage the food or worse. I only did this for a few minutes to see the system operating. I did not melt all the ice at that time. Also, it is of course dangerous to plug the fridge in with the panel open, so a great deal of caution is advised.
When I got my new thermostat I wanted to confirm that it worked before going through the install procedure. To do this I cooled it down and then used an ohm-meter to see that the circuit was closed. The important thing I found out is that ice-water, even 2 parts ice, one part cold water, was not cold enough to do this. Only when I put the thermostat into a cold freezer for a while did it get cold enough to close the circuit. I did this side by side with my old thermostat and saw that it was in face bad -it never closed the circuit.
This part from Part Select was an exact match for this freezer-on-bottom Whirlpool refrigerator. The connectors were identical so I did not have to solder wires together as others have need to do.
Some people get the ice off of the coils with a hair dryer. For me this could take half an hour. What worked better and much faster was spraying warm water on the ice with an old spray bottle. This adds extra water to the mix, but it did not overflow the drain pan. Even if it did, it would be easily mopped up if you can roll the fridge out.
One last thing. I suspect this thermostat broke in the winter, but with the dry air the fridge worked for a long time. Once summer hit and the house got humid, the coils iced up quickly.
I used board levers to do one side at a time.Kinda tricky, but you can hoist up fridge high enough to replace wheels. take your time think it out and be safe . Make sure you use saftey boards to support load to protect yourself==good luck A small mirror may help to see how the rollers alien in the supports.
Defrost in freezer not working, ice buildup in freezer, refrigerator not cold
Had to remove screws inside back of freezer panel, took off old thermostat. This one had a different plug on the end that wasn't compatible, so had to cut that off and wire it to the old plug end. Piece of cake. Put back panel back on and back in business. Hardest thing was getting the screws out!
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.
The part was delivered in just a few days. We merely had to unscrew the broken handle and screw in the new one. The color matched wonderfully and funcitoned beautifully.
1. Removed the cardboard cover. 2. Removed the terminal block and unplugged the old motor. 3. Removed three screws that held old motor to the bracket. 4. Removed the fan blade from the old motor. 5. Installed the fan blade (after cleaning) to the new motor. 6. Crimped on new wire terminals onto the leads on the new motor. 7. Installed the new motor using the fasteners provided. 8. Plugged the new motor wires onto the proper terminals in the terminal block. 9. remounted the terminal block. 10. reinstalled the cardboard cover.
While investigating a water leak I discovered the condenser fan seized. I removed the fan to prevent a fire and ordered the part. The hardest part was identifying the correct fan. That took longer than the installation. I cut the wires and spliced in the new motor. It rotated correctly and I replaced the crill. Done Total time of ice maker water leak repair and fan replacement about 1 hour.
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one. But Parts Select is a great place to order from. Thank you.
Freezer Cooling Problems - would get too warm then too cold. Condenser fan would run sometime but not always
Unplug Remove entire back panel (both chipboard and metal fan grill) Unscrew both fan mount plate screws - fan won't be able to come out because it is still plugged in When looking at back of fridge, locate a small plastic box to the immediate left of the condenser. It's a circuit block. Release the metal spring clip holding the plastic cover in place, and trace the fan wire connections back to the fan. Make a note of which wire is connected to which terminal (1 of the fan wires has white lettering and 1 is just black) Unplug both fan wire connects from circuit block to release the fan power cable. Remove the fan mounting plate Release fan blade clip by pressing fan against motor and unscrewing and remove fan blades Unscrew motor from brackets - note alignment of motor on brackets Mount new motor on brackets. Leave plug wire disconnected (replacement motor has a harnessed plug wire) Connect new plug wire to the circuit block keeping wires connected to the proper terminals Snake new plug wire behind condenser like the old wire was and run through cable bracket to the back right of the condenser Plug wire harness into motor and re-mount fan mount plate Reattach fan blade and secure using blade mount kit Replace back panels
I removed the panel in the back of the freezer and found the evaporator to be a complete block of ice. I defrosted it with a hairdryer. Following advice from the Partselect web site, I measured the resistance through the defrost heater. It was about 30 ohms, so I decided that it was OK. Next, I advanced the defrost timer manually with the compressor on until it turned off. The defrost heater did not operate. I concluded that the problem was the defrost thermostat. After installing it, the freezer worked properly.
simply removed old motor and replaced new. I'm over 82 and it was hard to get down and up to floor level!! One thing was a little puzeling -that was to insert the right screws which had a nitch in the end of the threds to keep it from loosening- I thought I was spoiling the threds cause I had to use a little pressure to start the screws and thought I had the wrong screws--they had sent several sets of them for different name brands- but II got it and everything seems to be allright - Could you tell me if I could purchase a replacement compressor and some refrigerent -the new kind. thank you, George Erlandson Only if my comp. goes out!!!
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
First it required defrosting since the cooling area was solid ice. Note that I replaced the defrost timer first and no difference. I pulled the icemaker and racks out, then removed the door by removing the 4 screws with 1/4" nut driver. One of the sliding drawer tracks must be removed in order to get the back panel in/ out easily. The 4 screws were easily removed with my nutdriver. The screws are not all the same so keep track! Next remove the 4 screws that hold in the vent assembly where the cold air shoots out (center). Remove all of the remaining screws in the panel in the rear of the freezer compartment and pull it out. The themostat is on the right side with 2 wires and a clip that holds it on to the coolant pipe. Pull it off of the pipe and locate the connector - 5-6" from the thermostat. Pull connector apart without damaging the wires inside. Install new part the same way the old one came out and reassemble in reverse order.