Wouldn't dispense ice
First pried off front panel, then removed 4 screws that hold dispensing unit in place, then rotated top of dispensing unit out, then pulled off electrical connector, then removed screw that holds switch in place and removed switch. Installed new switch by reversing above procedure. Only thing switch wasn't the problem. No ice problem was resolved later by replacing control printed circuit board which is located in the same area.
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice bin had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
Refrigerator would turn off and never come back on.
First unplug the refrigerator!
Removed the top shelf of the refrigerator. Pulled off the knobs from the temp slider controls. Popped the cover off of the light and temp control section. This Hotpoint model has both thermostat and defrost timer easily accessible in the refrigerator compartment. Used a socket set driver to loosen the screws and remove the temp control section and unplugged the wire connectors. This freed the whole temp control section. On the workbench removed the old thermostat by unscrewing the screws with a socket driver. Unplugged the wires from the old thermostat then put the new one in. Then put the new one in the same holes, reconnected the wires and reassembled the everything. Then simply put this temp control box back in the original place (and reconnect the wire plugs) and put the screws back in . The hardest part is re-aligning the holes and the control levers, but this is not too bad.
Plugged it back in and so far it has been turning on and off normally. (The old thermostat contacts were oxidized so I think this was the problem).
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Broken water line near solonoid to feed drinking water
bought an push in, in line connector and a new 5/16 plastic hose. I just replaces 2 feet of plastic hose from the selonid up an splices the hose using the connector. Worked perfect.
Flapper not sealing. Frost buildup on inside of freezer door
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Water Leak From The Ice Make - Water All Over The Frig
Replace the old water valve (wr57x11) with the new one (wr57x10051: make sure you unplug the 110 ac power . And close the water come to the refrig. First 1. Open the paper panel on the back with screw driver. 2 Use a small adj. Wrench to take the old valve of. 3. Label the connector and its terminals in a proper number to identify their connector. 4. Unscrew 2 water hoses - one to the drinking one to the ice maker. They are in diff. Sizes - make sure to mark where the hoses connected in case you need to use it again. 5. Cut of the thread section on the hose end - you do not need thread any more on the new water valve. 6. Make sure the new valve is in the same position as the old one. Then plug the water hoses to the valve - and connector terminals. There are 2 new terminal adapter in your new package. These new adapter will be fit to the old hardness for connecting to the new valve. 7. Secure the valve onto the refig frame then plug in the water hose to make sure no leak at the valve. The new valve has new type of self-lock plug ( not thread ) to the 2 water hoses. Make sure to press hard so the hoses are fit in to these new water . Valves. Turn on the water and power on on the refrig. That's all. Very simple save $300 for hiring the service man. Good luck to all.
Plastic water line gets brittle from compersor heat over time and eventually brakes. I tried to fix with 5/16 line from a locel hardware store but outter diameter was slightly smaller so connection to valve leaked. This OEM part fit perfect. I cut the line beyond the brake and connected it with the tube union part, Easy fix. Everything works fine with no leaks
the left drawer slide rail was broken from years of use.
First I removed the vegetable drawer and glass shelf. I matched up the 'new' drawer slide rail next to the broken slide. I then used a phillips head screwdriver to remove the 2 screws that held the slide in place. After removing the broken slide rail, I installed the new rail, replaced the vegetable drawer and glass shelf. New item worked like a charm. The drawer slide arrived really quick after my order was placed. Approx. 2 days after ordering the part, it was on my front door step.
After replacing the solenoid several months ago, I concluded that the problem could only be the electronic circuit board that controls the timing and delay. The part arrived sooner than I expected. Installing it involved removing only six screws and unplugging two connections. The whole project took only about 10 minutes and now my ice maker works like new. Total cost was less than $55. Saved me several hundred dollars not to mention my personal time had I called in a repairman.
The refrigerator was leaking water from the freezer section.
First remove all food from the freezer section, disconnect the power to the refrigerator and then remove all the shelves in the freezer.
Then remove the back panel inside the freezer by taking out the screws holding it in and then simply lifting it out. A Philips screwdriver and 1/4" driver was needed.
After the panel is removed, you can see the defrost heater screwed to the refrigerator coils. It's in two sections wired together. One section is screwed to the bottom of the coil and the top section is screwed half way up the coils.
Unplug the wires and thermostat (coming from the defrost heater) from the wire assembly located above the coils.
Next, remove the screws holding the old defrost heater (there are two screws for each element of the defroster)and lift the heater out. Pay close attention as to how the old heater is situated in the freezer in order to put the new one in the same way.
Attach the new heater by putting the bottom element on first and replacing the two screws to secure it. Be careful to keep the wires from tangling and attach the top element the same way.
Next, carefully connect the wires and thermostat from the heater back to the wire assembly the same way they were connected from the old defrost heater.
Place the panel back in place in the back of the freezer section, replace the shelves, and connect the power. You're finished!!