freezer was warm
Top freezer took off the panel in freezer and melted the ice around coils and found the defrost thermostat and replaced with the new one. Just followed the instructions from your video on line. Freezer works just fine now. Refrigerator is 38 years old.
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker. 2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,. 3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket. 4.Now take out 8 screws that hold the back panel in place and remove the back panel. 5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
The bulb has a plastic clear cover. That cover can just be carefully removed using a screwdriver. It's held in by a metal bracket. After you remove the cover. You'll just need to replace the bulb and then re-install the cover and bracket.
Based on the website I decided it was most probably the defrost timer, and that was correct. I ordered it, watched the video, and two days later the part was at my door. Took the nut driver, removed 4 screws, then removed the old defrost timer, installed the new one, re-installed the whole plastic assembly with the four screws, and done!!! Couldn't have been easier.
From most posts I've read, the defrost timer was the culprit so I blindly ordered one. Easy install but did not fix the problem so I broke out the ohm meter. The only other 2 items it could be all tested good with my meter so I bypassed the defrost thermostat (per forum help...actually quite easy)and it defrosted fine, which told me I needed a new defrost thermostat. Installed fairly easy and problem gone.
Ice maker quit making cubes, instead it made a large block of ice.
Unplugged the fridge. Removed water inlet valve from fridge. Used voltmeter to test for resistance (between 50 and 150 ohms). Didn't pass the test. My original part was 218720400. I ordered part PS468507 from partselect.com. My original part had a "garden hose" coupling so PS468507 fit the bill. This part's electrical connection wasn't angled the same way as the original so we had to finagle it. Hooked the plastic refridgerator supply hose up first. Then screwed on the copper "garden hose" connection to the valve using channel lock pliers. Was careful not to over tighten. Then the fun started. The electrical connector wires were a tight fit between the copper tubing and the refridgerator frame. Did I mention that the electrical connetion wasn't angled the same as the original? My daughter got her smaller hands in there and was able to make the connection. NOTE: Because of the angling issue I was unable to screw the anchor plate to the fridge. I made sure that the valve did not interfere with the fan. Turned on the water and checked for leaks. Plugged the fridge back in and in a couple of hours we had ice cubes. Works like a charm!
Made sure water was going into valve, shut off water to valve, removed it. removed two connections, replaced with new valve, Walla, off & running. Incidentally, rec'd new valve much quicker than I ever expected.
1. Turned off the cooling cycle and unplugged the refrigerator. 2. Removed all of the shelving and bottom basket. 3. Removed rear covering in the freezer section. 4. If frosted over, manually defrost coils with hairdryer. 5. Located original thermostat and after marking the wire locations cut the wires and removed the Thermostat. 6. Connected matching wires using a lighter to melt the wires together. Wrapped repaired wires with electricians tape. 7. Unable to install the thermostat in the recommended location (freezer is a tight fit) the new part was installed at the original location. 8. Replaced the rear cover and shelves. 9. Plugged in the refrigerator and set the cycle back to cooling. 10. Monitored freezer coils couple of days/weeks depending on how fast they freeze over (slots at bottom of cover) to validate if problem solved.
Temperature in both freezer and fridge sections to warm!
Dear Part-select, I had a fridge that was not working food was melting in the freezer, Beer was warm. You get the picture anyway using your site I found the parts needed to to fix the issue in fact I ordered two parts one fixed the issue 50% and the other like 30% of the time! both parts with overnight shipping were cheaper than 1 part if purchased at our local appliance part outlet:) not to mention the cost of a repair person. Thanks again! . Keep up the good work