Gasket was splitting
Had to remove both doors freezer and fresh section. Once I had door off removed the screws, and old gasket, cleaned all aroud where old gasket was, and proceeded to put new gasket on, It was hard lining up gasket with metal rods that hold gasket on could only do one screw at a time, because gasket kept slipping out, it was very time consuming.
Light rocker switch broke and refrigerator light couldn't go on.
I just popped out the old switch with a flat head screwdriver. Removed the connections and then installed new switch by reversing steps. Popped in back in and the light went on.
Removed the one screw and replaced with new end cap. Only disappointment was the beige color, as I would have preferred a white one. White color was not offered. Other than that it took less than five minutes. I'd rate it 4 stars.
Unscrew broken piece, pull it out and then insert new one, security it in place and connect water line again, make sure It's thight check for leaks and done
Unplug appliance. Socket wrench to unscrew two screws. Module drops down. disconnected two press-on wires by prying off with screwdriver. Removed old switch. Press-fit new switch. Reconnected two wires (color coded). Screwed module back in place. Plug in appliance.
I noticed that the refrigerator was having trouble maintaining temperature. Thought it might be time for new one until I found out that a new frig was $5k to $7K. Just happened to notice that the light switch didn't look quite right (was not sitting sqaure to the door). Once I pressed it it came loose. I then realized the the lights were staying on (50 watts of heating). Replaced the switch and the frig started working like new.
Pry old switch and pull out. Disconect two wires. Put two wires on new switch, must be inserted right and connections not loose. Put switch in, making shure wies do not come off and snap in place
Part was easy to order, delivered quickly, installation very easy. Just unplug the unit, pop out the old swich using a screwdriver, disconnect and reconnect leads and pop switch back in. Definitely recommend that you can do it too.
After finding water on the floor I investigated to find the leak. I Found theat the Icemaker fill tube on the back of the frig was cracked(due to someone pushing the frig back against the wall). Turned off the water supply to the icemaker. Removed the 2 screws holding the tube in place. Slid the tube out and slid the new one in. Replaced the screws and turned the water back on. Very easy, very inexpensive.
removed the 2 screws that held the panel in place, had to reach up and push on locking tabs to lower trhe front of the panel. was able to then push on the locking tab of the switch to release it. removed the wires, replaced them onto the new switch, and snapped the switch into place. the rest was reverse of the uninstall process.