Models > KTRI18KWWH11 > Instructions

KTRI18KWWH11 Whirlpool Refrigerator - Instructions

All Instructions for the KTRI18KWWH11
61 - 75 of 266
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Lights not working some times
Removed old switch and installed new - but did not solve problem
Parts Used:
Door Light Switch
  • Harry from COLUMBIA STA, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Making a god awful racket.
Ok its the garage "adult " Beverage chiller.

Easy fix First I removed the 4 screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires assembly was the reverse. and the beverages never got warm..
Parts Used:
Evaporator Fan Motor Kit
  • Michael from Locust Grove, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lost shelf support bracket
Ordered shelf support stud kit. Product was promptly delivered, and contained the parts as shown on website. Took longer to open the package than to replace the missing shelf support bracket. No problems. Would order from them again.
Parts Used:
STUD-SHELF
  • DAVID from LAFAYETTE, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
3 inches of frost in Fridge, 72 degrees in Fridgerator
First defrosted it to makes sure all Air flow was opened. Tested the Defroster heater with omh meter, it was OK. Found the location of the defrost timer on the online diagrams. Used nut driver to remove cover.
Replaced timer. The hardest part was decieding how to wire it up, tis was a universal kit and depending on how it was wired as to how often the defrost ran. The firt choice was every 8 hours. Since this was going to be opened often, I picked that one.
Plugged it with in 24 hrs freezer wall mesured -5 and the fridge was at 30, so had to warm it up a bit.
Now all complaints gone, Ice making has been doing better also.
Parts Used:
Defrost Timer
  • Gerald from Orangeburg, SC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
6 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
botrailer with frig without a icemaker
got the icemaker kit and started to add it to the frig found problems with the adaption to the frig in back for water filler tube but was able to make it fit. had to make a connection outside to water line with copper pipe added to hose with claps and saddle valve, turned it on and had leaks due to the schedule copper was the thin wall type, got thicker type and installed it, no leaks, started making ice. it was nice to get the right kit to make things work out. thanks
Parts Used:
Add-On Icemaker Assembly
  • rich from racine, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers, Wrench (Adjustable)
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
nosiy fan operation
most of the time spent on repair was removing the food from freezer compartment other than that removal of a couple screws and disconnecting and reconnecting wires not a huge ordeal
Parts Used:
Evaporator Fan Motor Kit
  • TOM from GRANVILLE, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer froze and refrigerator wet
First took all frozen food out and than undid the screws that held back on--than cut the wires that held the piece and replaced it but also found that the plug was frozen so we thawed that out, that is why it took longer. Used air compressor to blow air and it broke it free and than we finished and put the food back after it got cold. So far it is working find and to beat all we received our part the next day so my husband could fix it that weekend--Thank you for the quick respond-
Patricia in Marengo Ohio
Parts Used:
Bimetal Defrost Thermostat
  • Patricia from Marengo, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers, Socket set
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan motor stopped working.
I first unplugged the unit.
Secondly I unscrewed the back panel and removed it.
Third, I unplugged the fan, unscrewed it, removed it, and replaced it with the new fan motor.
I then plugged it to confirm that it worked and then put everything back together.
Parts Used:
Evaporator Fan Motor Kit
  • John from Clifton Heights, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lower Light Socket removed and Wires capped with wire nuts
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causing the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Parts Used:
Light Socket Kit
  • Wayne from Arlington, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replaced broken shelf supports
Took out old pieces and popped new ones in, just like that!
Parts Used:
Shelf Support Kit
  • Cheryl from Los Angeles, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan was making alot of noise
I removed all the shelves and the back shelf hanger. Removed two screws on the back plate.Pulled it out.Removed the screws that hold the fan housing. Pulled it out so I could write down the three wires color and location.Unpluged them.Removed the old fan and installed the new one.and put everthing back together.
Parts Used:
Evaporator Fan Motor Kit
  • JERRY from ALBION, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the light socket broke apart
I took out the old socket by moving a clip. Reattached the electrical wires, clicked in the socket and that was it.
Parts Used:
Light Socket Kit
  • Elyse from Skokie, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisy freezer evaporator fan motor
Removed the shelves from the freezer and the brackets holding it along with the covers for the light and plate for the ice maker (we don't have one). Pulled the ground wire from the tab off the port for the ice maker. Removed back plate exposing the fan motor and then the 4 hex screws holding on part #23 of the diagram which the fan motor is mounted to. Flipped it over, unscrewed the 2 hex screws from the fan motor mounting and removed it. Removed and replaced 3 wire connectors on new fan motor. Installed new fan motor and new grommets but used the old screws because the provided screws were larger. Pushed the new fan on to the motor shaft. Reassembled. Half hour most.
Parts Used:
Evaporator Fan Motor Kit
  • Lloyd from Long Beach, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Divider front of fridge hot to touch Condenser fan not working
removed back cover, removed fan motor and replaced with new one. connected new power wires. worked right away
Parts Used:
Condenser Fan Motor Kit
  • John from Holden, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker motor excessive slip (essentially worn out) & contacts were worn
1 removed bottom off old ice maker (3 hex screws) and ice drop shield (white plastic ice flips over into ice holder, old unit had different drop angle, see how described below, but I just musled it off the old unit) 2 removed "ice sensing bar off new ice maker and rotated mechanical sensor to on (leatherman tiny flat head) 3 removed end cap from new ice maker, then loosened to large screws (Phillips, leatherman) for motor unit cover. This allowed removal of ice drop shield on new unit (two tabs, one at each end). 4 removed ice drop shield and installed old ice dropshield on new unit 5 tightened two endcap screws (Phillips/leatherman) and reinstalled end cap 6 installed old bottom unit/tray on new ice maker (3 screws) 7 ensured wiring matched and routed plug properly 8 installed unit slides in 9 plugged unit to existing plug 10 installed old wiring shield (1 hex screw). Waited two hours to verify water valve worked properly, although IR codes did indicate "okay". Machine has been making ice and IR sensor shuts it off properly. So far a success. I have many spare parts if I need to do further repairs including a new water solenoid. Only saying it was a bit difficult because of the parts exchange, in actuality for me it was really easy.
Parts Used:
Add-On Icemaker Assembly
  • Richard from Blue Ridge, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the KTRI18KWWH11
61 - 75 of 266