Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Refrigerator and freezer compartments were not getting cold enough. Frost was building up on the back of the freezer compartment.
Tried manually defrosting several times and the unit would work for a couple of weeks and then get frosted over again. Using this web site I easily found and identified the parts I needed. I ordered both the heating element and the heater thermostat (If I am going to take apart the unit I only want to do it once). Both parts arrived very quickly and were exact replacements for the parts in the unit. I removed the ice maker by loosening two screws and unplugging the cable. The top part with the light came down by removing two screws. The vent at the back slid up and was removed. The back panel was removed by removing two screws. I could now access the evaporator coil. The evaporator coil was removed by removing two screws. The old heater element was on the bottom of the evaporator coil and the heater thermostat was on the upper right of the coil. I disconnected the wire at each end of the heater element. I removed the retaining clip at the bottom center of the coil. The heater element was removed by bending a tab at each end of the element and then sliding it down. I unclipped the thermostat from the coil and snaked the wires around the coil to the front so I could work on them easier. I cut the thermostat wires, stripped the ends, connected the new thermostat matching the wire colors, soldered both connections and sealed with some liquid electrical tape. I then snaked the wires behind the coil and snapped the thermostat onto the coil. The heating element slid up into the bottom of the coil and I bent the tabs back into place and reinstalled the retaining clip. I reconnected the wires to the element. Putting everything back together was a few more minutes. Total repair time was about 4 hours from starting to empty the freezer to when I turned the unit back on. By far the longest activity was defrosting. The actual repair itself was about half an hour. Emptying, defrosting and cleaning up were the other 3 and a half hours.
Took panel off back of inside of freezer section, took off old sensor from the evaporator, spliced new sensor into the existing wires, waterproofed spliced connections, snapped sensor back onto evaporator, then put panel back on the inside of the freezer. Really, it took only 10 minutes to fix. Now refrigerator defrosts like it used to, and temps have settled in at specified temps.
Noticed the problem in November 2009. Replaced Hi Limit Sesor for Defrost thinking it was the freezor temperature sensor. Did not fix the problem. Replaced Motherboard. Did not fix the problem. Called Sears Repair. They mis-diagnosed the problem and told me it was the sealed system. I doubted them and sent them home. Replaced the correct freezer temperature sensor that connects to the motherboard. FIXED. Removed a panel, cut two wires, soldered and insulated two wries, reinstalled panel.
Very high pitch whine. Not real loud but really annoying.
First I hired a repairman and he said that it was in the unit and would not be worth the expense to fix.
I started to research on the net and this was one possible source. ( evaporator fan). I had to take it apart to verify it. Then put it back together to use until the part came.
The next time went much faster as I did not have to take near as many screws out to access the fan motor. Very Happy to have it working fine again as a new relacement would cost $1200. Thanks much. Ron
Freezer and fresh food section getting warm due to inside coils frosting over.
No self defrost. Measured heater coil with ohm meter which was OK (not open). Ordered 2 temp sensors (there are 2 in freezer, 2 in fresh food sections). The original and the new all meaured ~150 ohms. Replaced one by one. This did not fix problem. Ordered defrost thermostat. Original measured ~150 ohms - new one was ~100 ohms. Unpluged refridgerator. Removed coil panel (4 nut screws) in freezer and light cover (1 small phillips screw). Locate defrost thermostat clipped to top of coils (orange / pink wires). Cut wires and unclipped thermostat. Stripped insulation off of wires and reconnect using wire nuts. Clipped thermostat back to coils. Ran refridgerator without panel on coils to see if coils frosted up again and listend for fans/compressor to stop ( took hours). Opened freezer and viewed glow of defrost heater. Problem resolved.
I had to remove the contents of the freezer, and remove the fan covers ( 2 screws) and the back of the freezer. I pulled out the evap motor assembly, removed the motor from that and re-installed the new motor into the assembly, (2 screws). Installed the evap assembly back into the freezer, ( another 2 screws), making sure to plug the motor into the wire harness and keeping the wires away from the fan blades. Then installed the back of the freezer (2 screws...again) and put on the 2 plastic pieces that completes the freezer assembly. I plugged the refrigerator back in and heard the fan start and knew everything was going to work fine
freezer fan failing; veried speed making whirling sounds
First, I removed all the shelves and the light guard. Second, I removed the nuts that held the fan guard and the freezer back in place (2 just under the fan guard and removed the freezer back. Third, lifted fan guard out of way (being very careful not to crack it..... cold plastic). Fourth, unpugged fan from pug then removed nuts that held fan bracket in place...removed fan. fifth, then removed fan blade and remove fan motor from bracket, removed two wires that went to freezer light (pay attention to where they go) and installed them into the new wireing harness. Sixth, installed fan blade on new motor, bolted new assembly in fan bracket, plugged in and reistalled fan into the freezer, replaced fan guard and freezer back (reverse order of above) and then replaced freezer racks. works beautiful.
the left drawer slide rail was broken from years of use.
First I removed the vegetable drawer and glass shelf. I matched up the 'new' drawer slide rail next to the broken slide. I then used a phillips head screwdriver to remove the 2 screws that held the slide in place. After removing the broken slide rail, I installed the new rail, replaced the vegetable drawer and glass shelf. New item worked like a charm. The drawer slide arrived really quick after my order was placed. Approx. 2 days after ordering the part, it was on my front door step.
I had taken the noise long enough and wanted to get this repaired. I didn't want to pay a repair man hundreds of dollars to do it so i decided to do it myself. I went on to YouTube and found a few videos that showed me how easy it was to do (very helpful).
I wasn't so sure all that noise would come from the Evaporator Fan motor so i ordered it and took the chance. For the small cost, it was worth the try.
All went well accessing the unit and removing the old part. Very fast indeed. However, the snag came when i went to plug in the new part electrical to the existing electrical adapters. The old part had 4 lead connections. The new part had 6. and the wires on the new part were different colors than the existing. I had to use some logic and courage to cut the wires on the new part and rewire the old adapter to this piece. Luckily, i wired everything correctly.
Calling Part Select got me a phone number for the parts manufacturer to help with the splicing but i opted to do it on my own.
The result is i have a noiseless refrigerator again. What should have taken 10 to 15 minutes took half an hour because of the wiring but overall, very easy.
After I bought what I thought I needed for the repair. I asked a friend to come over and look at it. He changed the the light socket and put the same light bulb in and it works great. I am returning the light switch but decided to keep the light bulb.
Getting on the internet was so easy. This was really very simple. Thank you for making what I thought would be a big ordeal into something very simple.
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
Twice I ordered the oven light bulb & each time the light bulb was defected
I had to call for a appointment for repair with GE Appliance because I thought then it . .was something electrical. The technician came out & checked everything out, turned out it was not electrical, The technician went out to his truck got a light bulb from his truck, put it in & it worked. It cost me $121.00 for trip charge from GE appliance for a light bulb that worked, your light bulbs were defective twice. Very disappointed with your products, cost me alot of money for a good light bulb thru GE appliance
I noticed that if I unplugged the refrigerator and plugged it back in a while later it would start working but eventually would stop. I deduced the problem was likely the defrost thermostat. I ordered the thermostat but it was in a difficult place behind the evaporator coil which I could not remove. While I was trying to work it into position my hand pressed against the defrost coil and shattered the glass sheath. I ordered the coil and finally managed to get it and the thermostat installed. The refrigerator seems to work fine now.
The gasket was breaking at the bottom, and the magnet was falling out.
I went in with the toolbox, and couldn't see the screws to loosen, so I tugged the gasket to see how it was attached. It just snapped down into a groove in the door. Pulled out the old one, snapped in the new one, and voila, it was done! Happy day, lucky me! Didn't even need my husband's help.
Thanks to the very fine posts on this site, and availablity of parts, I didn't have to call in a repair man. Due to the near-10 year age of unit, I first ordered a new fridge for the kitchen and moved the GE to the garage. Let it manually defrost. Figured based upon comments posted here I was dealing with the defrost system problem so ordered the temperature sensors for top and botton, the defrost thermostat, and the defrost heater. As a wise poster said, if I am going to pull the damn thing apart, I'm going to make sure I have all three parts in case I need a particular one. Do not have the skill or gauges to troubleshoot electrical components. Parts arrived from Parts Select in great time, and excellent packaging protection. Parts Select also has great diagrams of the unit, although I could not find written repair instructions anywhere. At first I was going to wait for the parts to arrive and replace everything, but since there was a dely in getting the new fridge in, and the freezer section of the old fridge worked fine, once I had defrosted the old fridge, and cleaned up a few of the rusted over connections, I put everything back together, to await new fridge and receipt of parts for old fridge. Well, as is the story of my Karmic life, once fridge defrosted, and I put everything back together, plugged old unit in inside garage, everything came back up working perfectly on the recommended settings for both freezer and fridge sections. Has continued to maintain correct temps for over a week now. Also have new fridge. Don't recommend the top freezer Maytag one for about $700, as construction is cheap, and temps fluctuate all over the place. Had Home Depot exchange out for the LG $740 top freezer model, and am really impressed with its construction and performance so far. (Both units are recommended buys by ConsumerRepots.Org) Not sure how long old unit will keep running correctly, nor what caused it to come back to life after the defrost. Perhaps a simple clogged drain tube, or shorted out rusted electrical connections that I cleaned. Anyway, am keeping Part Select parts on hand for possible future breakdown, and enjoying having both fridges running. We needed additional freezer space, and got the peace of mind of a new unit for the kitchen.