Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Refrigerator was not cooling properly.
I removed both plastic knobs from assembly faceplate. Then I loosened the screws holding thermostat housing to upper cabinet of fridge. Following this step, I loosened the screws of the thermostat to remove it. Next was the removal of the plate and vent pieces holding the thermostat wire sleeve in place. After removal of thermostat from sleeve; all steps were reversed and unit was up and running normal (cooling) with no problems. "Ahh, it's nice to have cool again "
No water flow to ice maker. Motor works perfectly.
After cutting supply line to ice maker and using syringe to back feed ice maker discharge outlet- I learned that there was no freeze blockage in supply. Using nut driver, the valve was removed and electrical and water lines removed and reinstalled on new valve. Reinstallation of assembly using nut driver completed the whole repair in less than 5 minutes. The part was a perfect match.
First I opened the fridge and removed the broken drawer. I then removed the new drawer from its shipping container and placed it on the tracks in the fridge. I then closed the fridge. Perfect!
Icemaker made a clicking noise then quit making ice
Motor from Part Select was 185W instead of 260W that came out of unit. After a bit of searching online, I found out the 260W had been obsoleted for lack of torque when harvesting ice.
Removal instructions: Unplugged fridge. Then I removed the screw on the bottom right rear of the unit. Then removed the plastic cover that covered the power connector. Pulled out the icemaker by pushing in the tab on the bottom left middle of the icemaker unit and pulling unit toward me. Unplugged the connector on the back right hand side. Removed the cover on the left side covering motor. Took out 3 philips screws and removed old motor with broken axle that spun freely (the source of the clicking noise). Put new motor in aligning harvest arm (the thing with the fingers) and did reverse of removal. Then plugged fridge back in and it started a harvest and the next morning I had a half tub of ice.
The easiest thing to do was pull the ice make off. After taking the 3 screws out of the wall of the freezer, take a screwdriver (flathead) and push on the tab for the electrical plug and wiggle the cord out. Then you can take 3 screws out for the main cover and another 2 screws on the next cover. There's the part, pop it out and replace holding pins and start the process of putting back together the opposite way you took it apart.
Did the diagnostics with the blinking light and couldn't decide what was bad....so ordered the control boards and the module motor assm. also. Turned out that it was the control boards and would suggest that future customers order that part first...if it isn't that then get the module and motor assm......these guys ship really fast and the prices are literally half of what Sears would charge, not to also mention the cost of their service man to walk through your door...OUCH!
Unplug the refrigerator. Snap off the ring surrounding the dispenser from the bottom. There are two slots on the bottom. This is the toughest part of the repair because my refigerator is older and the part stuck. Then unscrew the two hex screws and unsnap the parts, then reassemble with the new parts. Snap the ring back on and you're all set. Pretty easy.
I first opened a beer to gain some liquid courage. The crowd (dog and 2yr old) were anxiously watching while I first grabbed hold of the refrigerator door. The door swung open with a mighty roar exposing the huge gaping whole where the previous crisper pan once shelved itself in glory. I took aim, and slid that new crisper pan in like it was meant to be. The crowd went nuts...but probably because the tv commercial was over and Sesame Street was back on. Thanks partselect!
I first removed the power cord of the refrigerator from the receptacle. I then removed the screws (3 each) from both the emitter and receiver face plates with a phillips screw driver. I than carefully removed the connector to the each of the circuit boards. A simple pull maneuver. I removed the circuit boards from the face plates. I took the new parts and put them back in reverse order. I put the power cord back in the receptacle.
Ice maker not initiating harvest cycle (not making ice)
My troubleshooting narrowed down the problem to either the control assembly or the thermostat, so I bought both just in case. The motor assembly fixed the problem and I didn't need to install the thermostat.
The main thing I want to tell others who are doing this repair, however, relates to the thermostat. If you do indeed need to replace the thermostat (#PS380941) there is something you will need that is not included with the part or mentioned anywhere on this site. The instructions with the thermostat indicate you need to apply something called "Aluminastic" to the thermostat when installing it. I don't know about you, but that isn't something I have around the house, so be sure to order a tube of it when you get the thermostat so you don't have to take a trip to the store to get it to finish the repair.
old water inlet valve would not close completely, resulting in incessant leaks & puddles on the floor...
I removed the cardboard backer board at the bottom rear of the refrigerator. I had to remove two screws to free the old inlet valve from the frame. The old water tube fittings were compression (screw on) type, so I cut the ends off cleanly with a sharp blade. They inserted into the valve holes easily - just needed a good push to lock them in solidly. The tubes are different sizes, so it was easy to know which one goes in which hole - the electric connectors were easy to transfer from old to new... screwed the new valve back onto the frame, re-installed the cardboard backer, flushed the system -- and no more leaks!!
First I removed the old lightbulb from the socket and replaced it with a new one to confirm that the bulb was not the problem. I then pryed the socket out with a flat-head screwdriver. I could tell that the socket was anchored in its hole with clips so it was relatively easy to pry it out. Once the socket was out, I disconnected the lead wires and ordered a replacement socket kit from Partselect. When the new one arrived, I reconnected the lead wires to it, snapped it back into its hole, screwed in a new lightbulb, and presto!! The light was back on with no further problem. Thank you, Partselect!! A $15.00 part saved me what probably would have been at least a $100. service call and heaven knows what the technician would have told me I needed!!!
When I inspected the ice bin I noticed the bin coupler was in half. So I ordered the part. I removed the screw that held in the old part. I saved the two washers. Simply following the diagram on the website made reassembly a piece of cake. It is obvious which piece is the coupling as only it can fit the other coupling. I put the screw back in and it was done.
Took all the screws out of the plastic shroud that encloses the switch .There only four that I needed to remove, were the two in front where the switches that go,they go in horizontally and two in the back with large washers on them that hold the back to the top of the box that go in vertically.The switch was a snap ( make that two snaps ) the wiring is almost self explanatory. then it gos back to the way you took it off. OH! and don't forget to turn the light bulb all the way back in to the socket , so the light will work after you take the time to install it yourself.I had the water supply line from under the box to the water dispenser in the door and the total bill on that was one hundred thirty seven and a hand full of change.Don't be afraid to do it yourself the savings is enough on one one item to make several months payments on a new one Randy the "Handy Man'
I noticed the fan was running but not the compressor, they are wired in series meaning the compressor should also have power and you should hear the compressor. Could not hear compressor coming on, removed the white relay attached to the side of the compressor and could hear loose pieces shaking in relay. Ordered new relay and plugged it in, took less than five minutes. Very Easy. Thank you Partsselect