40 year old refrigerator brittle light switch fell apart
with a jewelry screwdriver I pried the lock tab in and pulled switch down carefully, the hardest part was that the power wire connector was stuck on good but the pliers and the jewelry screwdriver was its match for a bout 5 minute for one connection a simple pull off prong connection. After the wire connected back to switch it popped back in SNAPP
Remove the top cover above the door by lifting it slightly and pulling forward. I used a mirror to make sure that there was nothing in the way of accessing the switch from above. I used a blade screwdriver to press against the switch retainer on the topside, while GENTLY prying from below with another blade screwdriver to get the switch dislodged. Once the retainer was past the opening, I wiggled the switch downward and then rotated it to the left when the rounded top right edge of the switch was visible. This allowed the wiring to the connector to pass thru the hole. I pushed the wiring from the top and pulled from below to get the connector below the opening for the switch. I then unplugged the switch, plugged in the new switch and reversed the removal process feeding the connector thru first then rotating the switch to the right to get the rounded edge of the switch thru the opening, then pressed the switch up into the opening until it snapped into place. Total time less than 10 minutes.
Totally followed the instructions of the video that came with the sensor. Unplugged the the fridge, defrosted the freezer. Cut off the main sensor that usually is the one that goes out. Installed the the new sensor with new wire terminals, crimped them and covered with electrical tape. Fridge works like a charm. Partsselect is excellent. Saved me a few hundred dollars versus having a GE Tech come and do it.
Pulled the two wires out from the access hole in the lower part of the refrigerator. Put them in the spade connectors on the new switch, and pushed the switch into place.
Exposed evap defrosted with heat gun exposed defrost element defrost termination switch ok therminster didn’t check out the thermistor sends the signal to logic panel then run the the freezer ice machine and refer temps it took 24 hours before the system starting to show results freezer compartment 10 below ice compartment 0 degrees refer temp 37 degrees one refrigerant three different temps system is running at optimum performance 450.00 $ service call the thing with GE appliances there is no wiring diagram .thankyou parts select .ill use you on all domestic service calls.
Bad switch for door prevented interior light from coming on
Just as your video described, although due to the age of the fridge, it took a bit longer to remove the defective switch. Your video made this so simple, I can't imagine why we lived with a dark fridge for so long! I was ready to buy a whole new fridge, as repairmen are often nonexistent for small repairs. I am the biggest fan of your company & it's repair video. THANK YOU SO MUCH
Using plyers Pulled old switch down and out. Put new one in and pushed new switch up into position. The switch plugs into the contacts, no wiring needed. Worked like a charm. You saved me 200 dollars GE repair bill. Thanks
Refrigerator Running Warm, evaporator is not defrosting.
1. Removed and tested defrost heater, tests good. 2. Reinstalled defrost heater. 3. Removed and tested defrost over-temperature sensor, tests good. 4. Reinstalled over-temperature sensor using soldering iron, dielectric silicone grease, and heat-shrink tubing. 5. Removed the control printed circuit board and checked for blown fuse's, fuse's are all good. 6. Removed the defrost relay from the printed circuit board using soldering iron, bench tested the relay, it is good. 7. Soldered defrost relay back onto the circuit board, and reinstalled control board. 8. Removed and bench tested evaporator thermistor, the resistance is out of specification, ordered new thermister. 9. Installed new thermistor using soldering iron, dielectric silicone grease, and heat-shrink tubing. 10. Re-assembled refrigerator. 11. Installed temperature monitoring and recording instrumentation for 72 hour test. The defrost cycle is running correctly with a defrost termination temperature of around 90 deg-f. The defrost cycle ran twice while running the 72 hour test. 11. Removed test instrumentation and Put the unit back into service, The thermistor was the culprit. I bought the right part on the first shot, nice.
Fridge was freezing food near the back, adjusting internal temp not fixing the problem
Unplugged the refrigerator first....then on the inside of the fridge, I popped the temp sensor cover off (upper LH side) and exposed the old sensor. I snipped off the old sensor about 3" down from the end and connected the new sensor (which I trimmed down to about 3" long) with some heat shrink wire nuts/connectors. Let the fridge run for a day or so and confirmed the problem was solved! Oh yeah, there was no way to tell the 2 wires apart (power vs. ground) on the sensor. However there was a manufacturer's stamp on the wires. So note the orientation of the text and mark one of the wires with a sharpie on both the old and new sensor before trimming. This will give you a reference for which wires to connect when adding the new sensor to the old wires.