the part is a shell, it doesnt include the slider, gaskets, etc. these have to be ripped off the old cover -- usually by breaking the old casing. since the other parts were factory installed, they are damaged during removal and dont fit snugly, hence the need for glue. this issue should be clearly told to the consumer BEFORE ordering.
Freezer not getting cold enough to freeze ice cream
I took the advice off of your website about the only thing that will fix the problem is change the run capacitor. I felt assured that I would have a working refrigerator freezer after making this change. I was pretty disheartened when it didn`t solve anything. I was not going to take the new part back out after the small challenge of putting it in. The next day I found out how to test the old capacitor and it was still good. I will just have to eat the $49. I did learn not to take advice from a website even if it seems like a sure thing
Instructions say run capacitor is by motor, but on this frige its in the refrigerator compartment. The capacitors looks different, one square and the other long
Frame lower pan had cracked severely in several places
The only tough part was getting all the other parts off the old frame so that I could attach them to the new frame. In particular, the center rail required a lot of prying to remove, and I was concerned that it would break. Also, removing the sliders for the crisper drawer vents was a bit tricky; I ended up having to break the tabs that hold the vent covers in place, removing the vent covers, then removing the sliders.
Once I had reclaimed all the other parts, putting the new assembly together was pretty easy. My only concern is that the frame does not quite seat into the fridge in the correct way, it rides over the support knobs at the front.
Fridge keeps cycling on and off and a clicking sound happens every time compressor cycles.
I opened the back panel of the fridge and exposed the compressor. Unplugged existing run capacitor and installed new one with the addition of the sleeve that is stated must be installed around the run capacitor. Everything I read and on this web site says that based on these symptoms, that the problem is the run capacitor. I searched and search for a part called a start relay which plugs in to the compressor. This run capacitor plugs in to this other part which I take as the start relay.
Installing this run capacitor did not solve the problem. The fridge compressor keeps cycling on and off. Freezer doesn't keep as cold as it should.
I used pliers to pull lightly on the head of the switch, while I inserted a small flat head screw driver into the base of switch and gently worked around the edges to free it from the panel.
The old switch was hard to remove. Thinking that I may have to loosen the wires I used a socket wrench to remove a clamp. This was unnecessary. In the end the switch did come out using a large size screwdriver. The problem was that the expanding plastic tongue is not visible from the ouside so you have to try to feel your way around. If i had ordered the replacement before and not afterwards I would have seen this before hand.
After replacing the light bulb and still no light I manually pushed the light switch button. Intermittently the light would come on then go out. I removed the power plug from the power source then replaced the light switch. I plugged the refrigerator back in and now I open the door the light comes on and stays on until the door is closed.
The lights were on inside however the the water/ice dispenser did not work and the fridge and freezer side was not cooling
Simply take off the back panel. Remove the old run capacitor which is attached to the compressor by a white part. It pulls right off. You will have to unplug two wires. I took a pic to ensure I plugged the wires back up the correct way. Then I attached the new capacitor to the white part and put on the sleeve that was included, plugged it back into the compressor and zip tied the excess part of the sleeve. Once done plug fridge back up (always unplug electric devices when doing maintenance) to check before replacing back panel. It may take a few minutes before it kicks on.
I replaced the three sensors, 2 in the freezer 1 in the refrigerator. This was rated as the most common problem. Did not fix the problem. I then checked the ohms on the new sensors then the old sensors they were all within .5 of each other. So I got smart and went down the list of causes on their list. I emailed partselect and asked what the parts should read. They replied with that information and it turned out to be the voltage converter on the compressor. I ordered the part on friday payed for overnight delivery and it arrived tuesday. This as you can imagine makes me angry. But the part was easy to install and my refrigerator started working right away. I would advise anyone with this problem to start at the top of the problem list use a multi meter check everything on the list and only replace part or parts that don't come up to standards. This will save time and money and hopefully fix the problem the first time as you are not switching out parts and hoping that it solves the problem.
Removed back wall cover over coil. Defrost all ice with a hair dryer. Cut white wires and replaced Temperature Sensor. It has been working for a week and no trouble at this time. If you have this system on your GE refrigerator do this before replacing the motherboard. I must admit I was thinking that was the trouble. Motherboard was replaced after 5 years old now 5 years later my thinking is this a 5 year problem. So try the Temperature Sensor.
I found instructions on the web about how to do this repair, so I ordered the part with confidence. But the instructions simply said "pull out the old switchlight". That was actually somewhat difficult as the clip on the side intended to hold the part in was stubborn. I eventually used a utility to slice off the clip. From that point, it was just a matter of plugging in the new switchlight , which was very simple.