Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
I purchase a new veg. shelf cover and an additional shelf for my refrigerator. The parts came quickly and I am very happy with the new parts. I have posted your web site on my favorite for future use.
Remove back cover, exposing fan motor. Turn off power, remove nut on fan blades. Remove fan carefully, do not bend. Unhook wiring harness. Remove three screws that hold the motor on the back frame. Remove old motor, install new. Carefully, reinstall fan blades, hook up wiring, and your ready for tryout. Also do some cleaning while your there. Clean old fan blades with hot soapy water or contact cleaner. Everything runs better clean!
malfunction of the cold control (wearing out after 15 years)
1. Disconnected 120 VAC power supply from refrigerator. 2. Removed 2 philip screws from horizonal panel containing the thermostat. (Panel is in refrigerator section). 3. Removed plug module from panel which freed the panel which allowed me to remove panel to do repair. 4. Removed wires from thermostat (cold control), and mechanically removed thermostat from panel and installed new cold control (thermostat). Replaced wires on control. 5. Replaced panel and reinstalled 2 philips screws. 6. time to repair about 15 minutes.
I opened the refrigator door and inserted the shelf where the missing one shoud have went and I remoed the old Vegetable bin cover and replaced it with the new one.-----JOB DONE !
easy as 1.2.3 remove and replace before even thinking. just to let you know i also do this for a living but it is one of the most difficult thing when you have to stop and fix your own
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
Twice I ordered the oven light bulb & each time the light bulb was defected
I had to call for a appointment for repair with GE Appliance because I thought then it . .was something electrical. The technician came out & checked everything out, turned out it was not electrical, The technician went out to his truck got a light bulb from his truck, put it in & it worked. It cost me $121.00 for trip charge from GE appliance for a light bulb that worked, your light bulbs were defective twice. Very disappointed with your products, cost me alot of money for a good light bulb thru GE appliance
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.
remove lower back cover - disconnect wires to fan motor - place 6" fan to blow on condenser - fridge began cooling & freezing again - ordered part - part arrived - removed fan motor & bracket - cleaned brackets & fan blade - cleaned lint & dust from condenser compartment (took longer to clean than anything else) - replaced fan motor - replaced cover - was hero with wife ... :-)
This is a built-in unit. Remove the external bezel at the top of the unit. Reach through the unit and unplug the frig. On the compressor unit, you'll see a vertical metal panel. Remove the metal panel and the timer is right behind it. Remove one wire at a time and switch it to the new timer. Remove timer and replace with new one.
Just an added comment, GE Service wanted to put an "ice kit" into my unit. The full repairs would have cost $1,000. While I described how to replace the defrost timer, the problem was the tray heater. But that's another story.
The fan was the correct part. It arrived one day after my well trained son-in-law had left for Texas. I had to install the motor myself. He had trained me well; it was not hard. the most difficult was getting the two tabs on the fan housing to fit back into the frame of the refrigerator where they belonged. Thanks. the part & delivery were overpriced, but I needed seed and convenience. Thanks for getting it right the first time. John Moragues
After looking at our broken bottom shelf in the fridge many times a day for over a year, I finally got around to doing something about it. So glad that I did! First of all, the part was shipped amazingly quickly. I had it within two days (at regular shipping). Secondly, it was a cinch to install. What a world of difference! The only caveat is that the new shelf fits quite snugly. If you don't give the refrigerator door an extra push to close it, the door does not seal. Just a new habit we have to get into.