oven would not heat up error code F10 showing on veiw screen
move the range out and unplug power supply, removing the back cover allows access to the probe, this can be done with screw driver or nut driver, loosen clamp that holds power cord in place and move backing out of the way, be careful sheet metal can be sharp, locate the probe unplug the connector and remove screw holding probe, pull old probe out install new probe, fasten down and plug in connector. attach backing and tighten clamp on power cord, plug in to power supply, turn on oven and give it several minutes for probe to work, it took only 20 minutes to replace the bad probe and the oven works like new hop this helps
replacing the fan on a convection oven (fan was making a vibration noise)
This was the first time replacing the fan. It is a lot easier to work in the oven compartment with the oven door removed, only two screws on the door and the hinges were released. I found that a couple of the screws were either rusted or stripped so I used a pair of pliers to remove the screws that were holding the diffuser in place. Once there was access to the fan I found that the fan was warped and that the blades were scraping against the back wall of the oven. The next challenge was to remove the retaining nut. I used a sheet metal screw to secure the warped fan to keep it from spinning. once I figured out that you have to turn the retaining nut to the right to loosen, it came off easily. 1/2" socket with extension. When I replace the fan I used two washers for spacers to make sure that the fan would not scrape the wall of the oven. Its been tested many times and the oven does not make that horrible sound anymore.
Disconnected power, I removed the igniter from oven. Measured the resistance (275 ohms) and then the current draw. DO NOT ATTEMPT THIS UNLESS YOU ARE ABLE TO ACCOMPLISH THIS SAFELY. I made a harness and connected the old igniter to 110 V ac, Current draw thru the meter settled at 2.7 Amps. Too weak to fully open gas valve. Valve requires 3.2 - 3.6 amps to fully operate properly. New igniter measured 300 ohms and current draw was 3.4 amps. Installed new part and everything works fine. Correct part and good service from this site
Removed grates and range cover, unscrewed all sheet metal screws and removed cover plate. Disconnect electrical connector and then removed old ignitor/orifice ass and replaced it with the new one. Replaced all screws in cover plate and then reattached range cover and grates. Turned on the gas and it lit after a few sparks took place.
lost the metal clip inside the knob. so knob was loose
I compaed price at different sites and partselect .com was 30% cheaper for the same item. I received the part in 2 days by fed-ex. Doing the job was real easy.Just pull the old knob out and put the new one in.
Your service was OUTSTANDING...Ordered one afternoon, and before lunch time the next day, the delivery man rang my door bell...Thanks a bunch for you excellent service.....
When the part arrived, I open the box. Cut off my breaker to the range. Pulled back the stove and unscrewed the back. Located the probe, unscrewed the one screw that held it in. I then unclamped the white connectors, remove the old probe, replaced it with the new one reclamped the connectors. Screwed it back into the range. Replaced the back and screwed that back together. It was so easy I was very proud of my self. I cut the breaker back on and cooked a can of biscuits just to see if it really worked. And it did. My bread was not burned, it was cooked to perfection.
The light apparatus was loose behind the panel. Remove the remaining part of the lens. Install the new lens from the outside of the panel and hold it in position, protruding into the inside of the panel. Slide the light apparatus onto the lens from the inside, allowing the bracket to hold it in place - it will be spring loaded, which will hold it in place.