Jennair cooktop with coils lost one of its coil guides.
We bought the replacement Ceramic plug and wires, and opened up the jennair cooktop piece and rewired the NEW coil guide into the system. It works great.
burner receptacle failed (stove over 30 years old)
Took out burner (pulls out) Took out one screw that holds recep. in, cut the two old wires and attached new wires with wire nuts included in the new package.
i read the installation instructions and followed them. first i made sure that each heating element was off. next i carefully removed each one (a total of 4) from it's plug and lifted the worn out drip-bowl up and replaced it with the new one. finally i pluged in (a total of 4) heating elements and turned them on to make sure them were working and they did.
* Do not lose the supplied CERAMIC electric connecting nuts; they will not fry in the heat.
* Unplug the heating elements from the old receptacles, and remove any rings; unplug the cartridge by lifting up the back side and pulling gently toward the back of the stovetop.
* Unscrew the cartridge top from the cartridge base (about 12 screws) and the recepticals, and cut the old wire close to the old receptacle.
* If you have a spare magnetic thingy around, use it to hold the screws and not lose them.
* Screw in the new receptacles, route the newer wiring from the receptacles (use as much of the new wire as possible), back toward the wiring block on the cartridge plug.
* Recut the old wiring to accomodate the length of the new wiring, but leave at least 2-3" from the wiring block, if possible. Re-connect them using only the supplied CERAMIC electric nuts.
* The CERAMIC nuts allayed my fears about the effect of heat on a plastic nut; ceramic is designed for high-heat environments.
* Reverse the disassembly steps to reassemble and reinstall the cartridge.
Simple - needed to replace the drip pans on the stove between tenants in a rental apartment
This wasn't much of a repair -- rather a replacement of a simple abused part. At the same time, PartSelect allowed me to order what I needed after two failed attempts to buy replacements that would fit the range. I'll remember PartSelect if we need parts for other older appliances in the rental units.
First I disconnect the breaker. I removed the defected receptacle and cut the wires. I connected the new receptacle with parts with the new part. Turned the breaker back on and everthing worked fine.
I removed the burner elements for three burners by lifting the surface top and unplugging them. I snapped out the plug sockets that were burned out and cut the two wires, one element at a time. Using the included wire nuts I stripped the ends of the cut wire and connected each wire to one of the wires on the new socket. Once the wires were connected I snapped the sockets in place and reinstalled the elements, lowered the surface top and the range was ready to use.
After buying a 'universal' part at Lowe's and it not fitting correctly and shorting out the burner, I went online and found this source for an exact replacement part. Beside having to disassemble the drop in stove burner two or three times it went well when I had the correct part. I lost one screw somewhere and that delayed me a short time to find a replacement. Thus the 1 to 2 hours. It would have been about a 30 minute job if I had been smarter.
The burner was shortening out and would work sometime. The first time I replace the burner but the new one shorted out quickly.
I unplugged the stove. Took out the burner and removed receptacle by pulling it out of the bracket and clipping the wires. One thing you want to make sure is that when you clip the wires from the receptacle you're replacing you leave enough wire so that you can connect them to the wires on the new receptacle when it is in place on the stove. I had just enough but would have liked more. The bracket I received didn't match the one on the stove so I used the one on the stove since the receptacle itself was the same as the one I was replacing.
Shut off power at breaker box. Removed top burner unit. Removed old receptacle (Mounting screw was rusty so I drilld out the old one.) Cut wires from old unit. Stripped wires back on old unit. Attached old and new wire with ceramic wire nut. Attached new unit. Reinserted top unit. Reconnected power and "voila". Wife was smiling again.