Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Lower Light Socket removed and Wires capped with wire nuts
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causing the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
My refrigerator is over 10 years old. Over time a few of the door shelf end caps had broke leaving it hard to store things in the door. Recently one of the shelf support studs broke. We did an on line search and found Part Select and had replacement parts in just a few days.
My wife had the shelf end caps and trim replaced before I got home. The shelf support stud was very easy to install. A pair of pliers and a simple turn and the broke piece was out and the new one was in.
the process was pretty straight forward though the part came without instructions. We were able to replace the part improperly with ease. however, we were not able to get the pieces aligned properly for a long time. We ended up taking the door off many times to try to realign the pieces. After many hours I finally unscrewed the bottom cam while the door was in place. The piece popped into place and all was fixed. Had the part come with directions telling us to do this we would have replaced the cam within 15 minutes!
1. Put pieces of wood under door to support it. 2. Unscrew three screws holding door hinge. 3. Disconnect water line. 4. Unscrew screw holding each cam. One to door and one to hinge. 5 Replace cams. 6. Retrieve plate with threaded holes behind frame that the hinge attaches to. 7. Use thin philips screwdriver through the hinge bracket, shim, frame and screw plate to align it for the other two screws. 8. Replace all three hinge screws. 9. Connect water line fitting. 10. Remove wood for door support. 11. Check door for smooth movement and strong pressure when closed.
Freezer work perfectly, Refrigerator Stopped getting cold, water line froze, there was ice Forming around the condenser in the bottom of the refrigerator behind the drawers
Freezer worked great, refrigerator stopped getting cold and lots of ice formed around the condenser on the bottom of the refrigerator. First I had a serious ice issue, ice build up around the bottom of the refrigerator and all through the cold air vents, condenser and cooling fan. I unplugged of the fridg and let defrost over night. I also took all the cold air vents out and cleaned them. Then I followed the switch install video very simple switch install. Now the Refrigerator works Great nice and cold.
Freezer Temp was -20 to -30 degrees F. and did not defrost because of the extreme low temperatures.
The Video on U tube was helpful. I have a side by side model and it was difficult to work in such tight quarters to attach the new part . I found that by removing the cable assembly it was much easier to attach (cut and crimp) the new part on the outside , then reinsert the assembly. The new part resolved my problem. Don't panic when you try and remove the cable assembly. Hope this is helpful.
snapped the new shelf retainer end caps onto one new trim-door and 2 old ones and snapped all 3 back onto the freezer door above each shelf so I can now use 3 freezer shelves
Refrigerator door on a side by side unit would not stay closed.
First empty the shelves on the refrig. door. Then removed the upper hing cover and removed the three screws holding the hinge to the body of the refrigerator. Lifted the door off the bottom hinge and placed it clear of the unit. Inspected the bottom hinge and cleaned off the screw holding the closing cam, then with a nutdriver removed the screw holding the cam and removed the cam from the hinge. Installed a new cam closer, secured the cam with a screw. Hanged the door back on the lower hinge and re-installed the upper hinge. Job Complete!
light on inside, fridge and freezer warm up after initially cooling
Fridge/freezer warm. After unpluging and plug in again, both would get cold. Then, ice would partially melt in the freezer only to refreeze later. Noted large temperature swings in freezer-up to 48 degrees during defrost cycle. Finally after a day or two, both sides warming up permanently to room temp. Tapping inside the fridge near the cold control (thermostat) would cause the warm fridge/freezer to cool again. Installation is simple. Remove knobs and snap on face plate in front top of fridge. Remove screws allowing plastic cover to drop down which houses the thermostat at the inside top of fridge. loosen two mounting hex head screws from thermostat mount. Remove two plastic covers concealing thermostat wire that travels to vent at back of fridge. Remove thermostat. remove plastic tube over wire on old thermostat by slipping it forward and slide tube on to new thermostat wire. Install is the same in reverse. A thermometer in the freezer confirms very little temperature variation after install (3-4degrees); ice no longer melts, unit stays on!