Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Replace ice maker
New ice maker only used 2 screws and the old one had 3. This was no problem. The old ice maker had already been removed. Just loosen the 3 screws and unplug the cord to ice maker. Only problem with ice maker was with the cord, which I had to use the supplied adapter. It was too long and in the way when reinstalling the ice bin. The ice bin had a small notch area on the bottom left. I used a plastic tie to bundle the cord into the notch. Carefully placed ice bin and no problem. The first part I received was damaged and was replaced 2 days later by a brand new part. Customer service charged for the replacement part but said they would credit my charge card within 2 to 3 weeks for the damaged part. Its been a week and if they follow thru like the said I woild give Part Select 5 Stars for service and Parts.
Removed old bucket/auger assy from frig. Removed 4 + screws from front cover. Put front cover on new bucket/auger assy. Reinstalled in frig.....done. now have clean ice.
1) I removed the icemaker and placed on work table. 2) I pried the front plastic cover from the control box to expose the front base. 3) I removed the three mounting screws from the base (it is not necessary to remove the screw in the plastic gear) and removed the front base. This exposed the back base 4) Using an ohmmeter, I was able to isolate a bad contact on one of the three microswitches in the control box (the one that was mounted to the back base). Replacing this microswitch solved the problem.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Old Handles Were Worn And Sticky But The Refrigerator Still Looked And Ran Great
Popped out plastic decals on top and bottom of door handles removed and replaced with new ones. When ordering this product handles are refered to as stiffeners they come 2 to a box so only order 1.
Remove the two nuts holding the top of the unit to the side of the freezer using a 1/4 in nutdriver. Pull the unit out and unplug it from the back of the freezer. Remove all pieces of the broken stripper. The replacement part fits onto a peg on the back of the icemaker and into a slot. Bend into place and slide into position.
Broken water line near solonoid to feed drinking water
bought an push in, in line connector and a new 5/16 plastic hose. I just replaces 2 feet of plastic hose from the selonid up an splices the hose using the connector. Worked perfect.
The comments from customers experiences gave me the confidence that the defrost timer was the problem since the compressor was still working and it went just as they all said, four 1/4' hex head screws and I had access to the old timer, unplugged the old ,plugged in the new and put the four screws back in. Nothing happened so after a while I looked a bit harder at the accessable part of the timer after intallation and saw what looked like a dial. I turned the dialclockwise and immediatly the compressor turned on. I have not found any information as to how much or little to turn this dial which obviously is an adjustable cycle setting so I just turned it all the way, so far everything is working alright.
Flapper not sealing. Frost buildup on inside of freezer door
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
Condensor Fan not turning. I thought it would be an easy fix. I thought I could pull off the shroud and fan assy - no joy. Too many copper pipes and lots of tubing in the way. It took 90 minutes to remove and 30 minutes to install. The BIG hint here is to loosen the shoud, pull it back as far as you can and then remove the nut that holds the fan blade in place. THEN you can remove the motor. Get the new motor back into the shroud, get the blade back on and then tighten the shroud back up.
Turned off the refridgerator. Took everything out of the freezer compartment & put into ice chest with pleanty of ice on top. Removed 2 screws holding the ice maker in place & placed ice maker aside. Removed shelf. Removed one screw on back plate, pushed up on the holding tabs at the top of the back plate & removed the back plate. Removed 3 screws holding the motor bracket in place along with the 3 wires. Installed new motor & used the wire extensions provided due to the electrical connections on the new motor being on the opposite side. Had to bend one wire tab down to clear the motor bracket. Turned refridgerator back on to ensure correct rotation on the fan. Reinstalled back plate & ice maker & shelf. Waited 30 minutes before putting food items back in freezer compartment.
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Plastic water line gets brittle from compersor heat over time and eventually brakes. I tried to fix with 5/16 line from a locel hardware store but outter diameter was slightly smaller so connection to valve leaked. This OEM part fit perfect. I cut the line beyond the brake and connected it with the tube union part, Easy fix. Everything works fine with no leaks