Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
broken right side rail.
I had to remove the glass shelve, the two drawers, and the middle rail. Once I did that, I slide the unit out together. I placed the unit on the floor and removed the one screw located on the far backside of the unit. I had to remove a slip cover (it had the kenmore logo and the writting on it) it was a snap on, so no problem. Glad it was not gluded on. After the old part was removed, I put the new part on. Put the two screws back on and snap the cover back on. Then I put the whole unit back in. This included the glassshelve and drawers. The process was pretty easy. Good luck with your change.
R/S rail was broken draw would not slide in correctly.
Took out both draws and glass shelf, removed the entire lower shelf housing. I snapped off the front rail aluminum face to expose the screw. Unscrewed both screws and removed the rail and then just reversed the procedure to put new rail on. It was the most cost effective way of doing it. All the pieces are there on the GE website as long as you know the model number. You will save a lot of money by doing it yourself.
The left side rail had broken where the screws secure it to the delidrawer
The left side rail had broken where the screws secured it to the drawer. Your replacement part fits perfectly! In fact the drawer slides easier now than it did before!
I’d read that I should keep the original screws. They were a bit too big to fit the replacement part. A trip to the hardware store solved the problem and the new slide is now in place.
Your description and drawings for this part really helped me out!
Thank you so much for having this service available for my old but trusty refrigerator!
40 year old refrigerator brittle light switch fell apart
with a jewelry screwdriver I pried the lock tab in and pulled switch down carefully, the hardest part was that the power wire connector was stuck on good but the pliers and the jewelry screwdriver was its match for a bout 5 minute for one connection a simple pull off prong connection. After the wire connected back to switch it popped back in SNAPP
Remove the top cover above the door by lifting it slightly and pulling forward. I used a mirror to make sure that there was nothing in the way of accessing the switch from above. I used a blade screwdriver to press against the switch retainer on the topside, while GENTLY prying from below with another blade screwdriver to get the switch dislodged. Once the retainer was past the opening, I wiggled the switch downward and then rotated it to the left when the rounded top right edge of the switch was visible. This allowed the wiring to the connector to pass thru the hole. I pushed the wiring from the top and pulled from below to get the connector below the opening for the switch. I then unplugged the switch, plugged in the new switch and reversed the removal process feeding the connector thru first then rotating the switch to the right to get the rounded edge of the switch thru the opening, then pressed the switch up into the opening until it snapped into place. Total time less than 10 minutes.
Water Leaking out of bottom of refrig first then out of vegetative bins underneath
Replaced defrost thermostat and defrost controller and also noticed that run capacitator for compressor almost oxidized in two and ordered and replaced and cleaned out drain tube and invertor (which was blocked by frozen peas and other food)or water to drain during defrost cycle and put everything back together and seems to work fine now....storing beer in outside refrig now