Enter the code USA15 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on July 1 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Easy Fix
Was really basic, simply slide off the old caps, slide on the new ones, put the shelf back where it goes, push down lightly so as to not snap the new caps, and viola, complete. No more than 2 minutes worth of work. Great part at a great price, shipping was more than the part itself so I bought 2 of each. Only problem I ran into was that I ordered the top shelf caps instead of the bottom the first time, so I had to reorder.
Freezer frosted up, refrigerator compartment heated up
I removed the housing at the top of the refrigerator compartment that contained the reefer light and temperature adjustment knob. This required a small nut-driver. Inside, I found the old defrost control, unplugged it, unscrewed it with a Phillips screwdriver, and replaced it with the replacement part. Then I replaced the housing to its original position.
Removed the housing with the light, 4 hexhead screws. This exposed the defrost timer, removed 2 hexhead screws, electrical connector and reassembled the unit.
First I removed the plastic grill (pulled out, no screws) from bottom of refrigerator, then I removed electrical plug & two screws from old timer (timer located on the front inside left lower side of refrigerator). Installed in reverse order.
Door shelf retainer bar end caps broke off at insertion point.
Removed plastic male parts. Inserted new end caps onto old retainer bar. Inserted all into door. A snap, but I didn't need to order the retainer bar after all - the old one was the perfect fit and the one I ordered was way too long. I returned the new retainer bar, and the shipping was more expensive than the part.
I removed the plastic shroud on the ceiling of the refigerator, unscrewed and unplugged the old defrost timer, and replaced it with the new one. I reinstalled the shroud with the new timer installed.
removed all items from frig.. removed shelves, loosened one screw on each slide bracket and moved them down and out of the way of the rear panel....removed 6 screws in rear panel...removed all ice on coils with a heat gun...located defrost stat, replaced...crimped wires...re-installed rear panel and shelves! On left side of frig. in front bottom..located defrost timer..removed trim piece, loosened 2 screws....removed and replaced defrost timer...plugged in the frig. and it started!!!!
The refrigerator in my new apartment was missing the brackets that hold the bars so that things don't fall off of the door shelves. It was missing several off of the refrigerator door and one off of the freezer door.
I just had to make certain I had the correct end-cap for the correct side. I placed the two little curved pieces into the slots and applied some downward pressure (gently) onto the end-cap till I heard it "snap" into place. You could then see that it was held in place securely. I did first one side, then fed the bar into it, then placed the other side onto the the bar; inserted the end-cap and secured it in place.
HINT: I myself mistakingly ordered the same exact end-cap for both the freezer and the fridge doors. I was unaware (I failed to check), that the end-caps for the freezer are not the same end-caps as the ones for the fridge door. My refrigerator uses three different end-cap sizes; one size for the actual fridge door and two additional different sizes for the freezer door. Not wanting to exchange it, I used the one I ordered anyway. It still works, but makes the bar protrude into the freezer more than it would have, had I ordered the correct size.
SPECIAL NOTE: This company got the correctly ordered products to me within a couple of days. I would definitely order from them again without hesitation. I am very happy with the product and service. Smooth.
My fridge side had warmed up to 70 degrees but the freezer side was still cold. The coils inside had iced up. After thawing with a hair dryer, it froze back after another week. I removed the old defrost thermostat and wired the heater strip directly and turned on the defrost timer. It began melting the ice so that ruled out the heater strip being bad. I couldn't get a reading with my ohm meter on the defrost thermostat so I took a chance and bought the part. Installation was a breeze and it fixed the problem.
1. Turned off the cooling cycle and unplugged the refrigerator. 2. Removed all of the shelving and bottom basket. 3. Removed rear covering in the freezer section. 4. If frosted over, manually defrost coils with hairdryer. 5. Located original thermostat and after marking the wire locations cut the wires and removed the Thermostat. 6. Connected matching wires using a lighter to melt the wires together. Wrapped repaired wires with electricians tape. 7. Unable to install the thermostat in the recommended location (freezer is a tight fit) the new part was installed at the original location. 8. Replaced the rear cover and shelves. 9. Plugged in the refrigerator and set the cycle back to cooling. 10. Monitored freezer coils couple of days/weeks depending on how fast they freeze over (slots at bottom of cover) to validate if problem solved.
Freezer was freezing but refridgerator was warm. Checked fan and it was not turning.
Unplug fridge. Removed 2 nuts to get the vent plate off and two more nuts to get the motor mount off. Removed fan blade and then the fan motor. I put the new motor in and put everything back as it was. It was very easy. I had items in the freezer, so I didn't turn the fridge off other than to replace the part. It took about 6 hours for the fridge to reach optional temps because I didn't get to defrost and the fridge had to work it out on it's own. If you don't need the freezer then you should turn the refridgerator off for at least an hour and open the doors so the coils can defrost and any ice blockage between the freezer and fridge portion can melt away as well.
Top freezer took off the panel in freezer and melted the ice around coils and found the defrost thermostat and replaced with the new one. Just followed the instructions from your video on line. Freezer works just fine now. Refrigerator is 38 years old.