Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Ice maker failed
Watched YouTube video. Very easy. Used my cell phone camera in ‘selfie’ mode propped up in the upper right hand corner of freezer to see the 2 hidden screws.
I remembered to unplug first. took the little cover off on the bottom, unscrewed the 3 screws. then just held the base that the fan is on and pulled rite off, pushed the other one rite on. it took me five min, i want to say thanks to parts select, had the part, fast shipping, great job, thank you.
Followed video instructions which were to unplug refrigerator, on lower back use screwdriver, loosen 4 screws, take off plastic cover, pull out fan, replace with new fan, replace cover and 4 holding screws, plug in refrigerator. I am female, 77 years old and if I can do it, anyone can.
Lightning struct the house and fried the evap thermostat
Noticed the evap fan wasn't working, so trying to disconnect the wire broke the connection so had to order a new motor. Installed the motor but it still didn't work. Had a technician look at it and he said it was the control board. Ordered and installed control board and still didn't work. The only element left is the evap thermostat. Jumped the thermostat and it worked so ordered and installed a thermostat. It works now
Evaporator fan motor quit and would not circulate cold air from coils.
Remove shelves and rear panels to get to motor. Motor is held in place on shroud by simple strap. Remove fan blade, then un hook strap, remove and save rubber spacers on old motor to reuse to remount new motor. New motor Mew motor has wiring harness that is universal. Cut out the three wires that go to the new motor leaving long as possible, cut wires from old motor as long as possible, strip ends of all wires 1/2 inch, connect wires by color,slip into provided wire connectors and crimp. Pull on wires to insure connection. Tie wires together so they don't touch the coils. Plug in and check operation. If all is working unplug and replace all covers and shelves. Plug back in and it will take few hours to reach operating temperature. Video of side by side repair shows easy removal of panels and motor.
First download schematic from frigidaire.com and watch a few youtube videos on fixing refrigerators .At first my guess was the timer was stuck on the defrost mode .However after studying the schematic I checked to see if the power was being sent to the compressor through the starter ptc .The 110 v was there after pulling off the connector .Also the condenser fan was on confirming this . however the compressor was stone cold .the compressor has 3 inputs whose resistances across all seemed good (see youtube videos) so it was probably the ptc starter or the 15microfarad capacitor .I changed the capacitor first -not the problem .then the ptc starter .immediatey the compressor started warming and after a few minutes cold air was being blown in .Very satisfying !
I worked for GM as a Frigidaire Tech, before starting my own business. I have retired now. I took the three screws off the back of the bracket holding the motor. Disconected wire harness and pulled out the motor. Reverse to install. servantoftheking@hughes.net