Freezer frozen, refrigerator warm
removed the screws/nuts; pulled the back panel off, removed the old thermostat (wires just popped apart) replaced the new thermostat (wires just popped back on) replaced the back panel and the nuts and TaDa!!
Removed the back panel in freezer compartment with the nut-driver. Then I cut off old thermostat connections, and spliced in new thermostat connections (repairman had already replaced defrost timer, and said not to trust connectors included on wires-they failed often). Then I snapped thermostat itself onto cooler coil. So far so good, fridge is running at 35-40 degrees a week later. Thanks Parts-Select!!!
My Freezer Was Frosting Up, My Ice Maker Was Not Working ,And My Fridge Was Warm.
Had to remove all screws on rear back cover of freezer inside, unplugged refridgerator, uncliped thermostat, unpluged thermostat. Replaced thermostat with new one in the same location, and let defrost fulley. Reassembled, pluged in, and tested. All was good. But I did also replace timer at first part of the repair so I suggest you replace both at the same time.
loosened 2 screws with 1/4 inch nut driver, disconnected electric connection lifted old ice maker out, replaced it with new one hooked up electric plug tightened 2 screws
This refrigerator is less than 2 years old. I have had to replace the ice maker 2 times now. Cheap ass parts! Only one ice maker you can order so just be prepared to replace it yearly!
We love our ice here. I seem to replace the ice makers one to two times a year. Generally the ice cycle gets off for some reason and it starts making loud popping/clicking noises (gear grinding). Its easy to replace. Simply loosen two screws holding the unit to inside of freezer and disconnecting the wiring harness. Unit slide up and out. Replacement is super easy (5 mins or less). Bam! Ice!
Unplug refrigerator , loosing two screws. Lift ice maker up to remove from position. Disconnect electrical connection. Reverse procedure to install new ice maker.
removed ice maker storage holder and then remove two philip screws and unplugged four pin connector. removed ice maker and installed new one . very easy to do
freezer section remove ice trays ,shelves,unplug ice tray.use 1/4 nut driver remove back panel,use hair dryer thaw ice from evap coil ,unplug tstat remove install new one.plug in ice maker,put back panel back on ,ice maker and shelves plug refridgerator back in
The freezer was too warm. The fan was running: the diagnosis tool did not work!
I used the tool at Partselect that in theory allows diagnostic of the problem to be repaired. The result was that more tan 90% of the time with the introduced symptoms it had to be the thermostat. I order the part, got it quickly and installed. It did not fix the problem. So, be careful with the diagnostic tool, because it is just based on what most people buy when they have a particular problem. Videos for installation are great. If diagnosis was better, this would be fantastic. In my case there might be a different problem.
Pulled unit away from wall and shut off water and unplugged unit. Installed water valve and reassembled, plugged back in and turned on water and checked for leaks. All good. However there is no water getting into the ice maker. The unit itself is going thru a cycle of attempting to make ice and the bail is moving and you can hear the solenoid activate but no water. I have tried to blow thru the tube going to the maker but it seems to be plugged by something. I do not know if there is another valve up there or how to clean it out. Any help would be greatly appreciated.