Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
converting to LP gas
First I removed the front panel which allowed access to the burner assembly. Then I removed the gas connector and elbow from the back of the dryer. Then I removed 2 screws that hold burner assembly in place and 2 screws that hold an angle brace for the burner assembly. Had to loosen the screw that clamps around the gas pipe holding it in place clear in the back inside dryer housing. Unplugged all wiring connectors, then I removed the burner assembly and removed the 2 screws holding the burner tube to the valve. Remove the orifice and replaced with the proper size for LP gas. Then removed the blocking pin and replaced with one for LP gas. Then reassembled in reverse order. Actually pretty easy.
Unit would shut down in the middle of cycle and flash E1 trouble code
Had to remove the back of unit to access the area of subject part by removeing 12 to 14 screws also the gas line had to be removed. Two screws held the part in place. Unit now runs normal.Saved alot on repair costs!!!!!
I tested the dryer coils and found that they were getting a voltage but would not open the gas valve. Coils were not bad but weak. After they warmed up they would not open the gas valve. It took 10 min to repace both coils and the heat sensor.
I unplugged the dryer,removed the two small screws on the front of the dryer and pulled the bottom forward. The two wires connected to the door do not have to be removed. With an electrical tester using the Ohm setting I tested the Radiant sensor and the Gas Valve coils. The two terminal coil was DOA. The dryer can be operated with the front open as long as the door wires are connected. Symptons: The igniter would heat up and not release gas. My repair was successfull due to this awesome website and the super fast shipping service. AAAA++++
I took off the front panel via 2 screws on the inside of the dryer with the top panel in the maintenance position. Pulled out the tub(cut my hand pretty bad in the process but continued). Did some cleaning and I had to google how the belt tensioner goes into place. Rather difficult on your own i held the belt and placed the tub back into place while placing the belt around the tub putting it in the correct area. thats pretty much it and began reinstalling the parts i had removed.. easy fix now that i have done it once. This is all after my landlords said they werent replacing it and just to have this one hauled off, so all in all i have a 26 dollar dryer now:)
somthing fell down in the blower motor compartment and busted up the bloewr motor fan,and was making noise and out of balance.i changed the blower motor and runs like a charme
the problem was not the igniter its was the thermal fuse I broke the igniter during inspection of the problem be careful its a very easy thing to break repairs complete thank you parts select for the quick shipping and low prices
Needed to change rear exhaust to the side to fit dryer into my closet.
First, I opened up the front of the dryer and then unscrewed the entire back piece. I assembled the new exhaust piece from the kit. Next, I took out the old straight rear exhaust and then replaced it with the elbow shaped left eshaust from the kit. Lastly, reattache the back and front pieces of the dryer.
Pulled the big front panel by removing two screws near bottom of front and pulling out at bottom until the top pops loose. Vacuumed out all of the dust and checked for loose connections. Ran dryer - igniter would light, but no gas. Checked the two solenoids with a VOM. the one with the two leads would intermittently read Infinity (open). Super simple repair. Remove two screws on solenoid bracket on top of the gas valve, Replace solenoid and plug it back in with the easy push-on connector. NO PROBLEM - all fixed.
I disconnect the power, then the vent pipe. I removed the back panel of the dryer to access the pulley and removed the belt. Replaced the back and put everything back together.
Our dryer would not heat and it seemed that no gas was coming from the regulator. The igniter was working fine but the burner never turned on. To check the problem, i followed the instructions to remove all body panels until I had access to the burner assembly. I dismantled both gas valve coils and tested each one for open or closed circuit using my multi-tester. I found that the three terminal gas valve coil was an open circuit and was not functioning so I ordered a new one from PartSelect and within just a couple days, had the drier back up and functioning. I also replaced the igniter due to a malfunctioning igniter that has been changed by the manufacture. I must say that PartSelect has the fastest shipping I have ever seen. One part I ordered was at my door in less than 24 hours and I only paid standard shipping...un real! OUTSTANDING....5 STAR SERVICE