Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Dryer would start, and get warm, but not keep warm.
First watched a youtube video on the process. Took off front cover. I'd already replaced a belt so I knew what to expect. Two screws holding the retaining plate on top of Coil Valves (both). One screw was a bit seized, so a bit of persuasion w/ the pliers was in order. There was no info on which way up, but luckily I noticed a bump on each valve, and two matching holes on the retaining plate. (Note to others trying this) Of course while re-assembling a dropped and temporarily lost a screw, then one of the machine screws that hold the front cover on, but other than my stupidity, and frustration that job was easy. The cycling thermostat I just got "just in case". I knew the main thermostat was working, but couldn't accurately check this one, so I got a spare and replaced it. I'm sure it was one of the valve coils as I'd read another user had an issue where the coil would work fine at first, but after it got hot would not work. After a cool down, it'd work fine again. So all in all, easy job.
First and Foremost i was told that my problem was with the Thermal Fuse (Fix Ya.com), Then with the little Electrical knowledge I have thought Fuses don't turn on and off,If the fuse was bad i would get No Heat. (Even for a second) Fuses just don't turn on and turn off intermittently,when they go there done! So after a little research i decided to order the gas coil valve. I tilted the top up, two screws on the front panel, took that off and the valves were exposed,(bottom left) two screws too remove bracket then installed new coils on bracket,put back together and I Have Heat Again! NO problems what so ever since new install. I would say having not been for cleaning lint build up inside the machine (been 6 years) the Whole project took me Ten Minutes.
Gas dryer would not heat - pilot lit briefly then went off
Same as others. 1. Unplug dryer from power source 2. Use nut driver to remove two front screws at bottom of dryer 3. Disconnect cable connected to Secondary Coil (this is the coil towards the rear of the dryer) 4. Use angled phillips screw driver to loosen screws holding cap on top of the two coils. (Angled tool not required but seemed easiest to me) 5. Slide top cap back towards lock screw to allow coil to be lifted out 6. Remove and replace secondary coil 7. Replace cap, tighten screws to lock in place, reconnect cable to coil 8. Restore power to dryer, test and confirm gas flame stays lit 9. Replace lower front panel on unit
PartsSelect a great resource to use for home repairs like these. My first time using site and doing this type of work, now PartsSelect my first source to go to on such items.
When door was closed the timer could be heard to continue clicking. also, drying cycle started immediately upon closing the door.
Two screws hold the top control panel in place. Once removed the panel could be tipped forward. The Push to Start switch had 2 wires which were removed and swapped to the new starter switch. The old one rotated 90 degrees to remove and the new one installed. Panel was resecured to the top of the dryer and tested. Worked first time. Finding the part on the website, ordering it, receiving it quickly and the install couldn't have been easier or more pleasant or efficient.
Disconnected Power cord, removed vent pipe, removed back panel, had to slide top cover off to remove additional screw holding back on. Went down to where the Idler Pulley was, removed old piece by depressing on the spring loaded actuator and slid it off the belt and all. Replaced same as removal.
Dryer had no heat at all. This is an older gas dryer.
Cleaned out years of fuzz behind lower access panel and noticed where the igniter sits there is a metal tube about 1 inch in diameter. It had rust on the end and was starting to flake away. Found some helpful hints about how to test the igniter. Very easy, just used an ohmeter. Unplugged the 2 pin wire connector and checked for continuity. 1 lead on 1 pin and the other on the other pin., igniter side not the harness side from the dryer. A good igniter should read less than 5 ohms. I don't know the spec. exacttly, but it should not read open or infinite resistance. My meter read an open circuit. Removed the tube and igniter assembly, mine only 2 small bolts. I found the igniter element cracked. Ordered and installed igniter and tube assembly. This was a very easy install. 20 year old dryer works great and it's better than spending $500.00+ on a new one.
Gas would not turn on after around 10 minutes of "normal" operation.
I've nothing to add to the techniques already described in the other narratives except that the dryer operated normally at first, but then after around 10 minutes the flame no longer cycled. I suspected a bad high limit thermostat since the valves seemed to be working. I ordered the replacement coils only because they were listed as the most common thing to fail. After replacing the T-Stat there was no change; I started checking things w/ a multimeter and found that all the T-Stats were closed. I should have done that at first. Anyway, since I had the new coils I decided to put them in. The dryer has workd perfectly ever since. Lesson to be learned: the coils may check ok when cold, but become inoperable after heating up a bit.
I removed the Drier Door and removed the Front Drier Panel exposing the Gas Valve & associated parts. I removed two (2) screws holding the Gas Valve Coils in place & replaced the 2 terminal coil, then replaced the screws, Front Cover & Drier Door. I liked the results so much, I ordered the other Gas Valve Coil and will replace it also when it arrives.
After opening the bottom access panel, I found a lot of lint build up which is very flammable. I took my leaf blower and cleaned it all out. Then I just followed the instructions that came with the part. But be careful as the igniter is fragile. I broke the first one...
My drier would start create heat,than stop heating after 8-10minutes.
After reading the many different common stories,I replaced both coils (m series).Very simply lifted up the top of driver,held by 2 snap springs and 2 lint vent screws.Removed front cover,2 screws and 2 bottom snaps,coils down on bottom left.r/r both coils,reinstalled covers and let there be heat!This website is a blessing!!
ignitor failed to ignite gas or would fail to after first ignition.
Watched youtube video to problem shoot. Cause determined to be coils bad. Searched web found Parts Select to be easiest site to deal with and had coils for best price. Followed instructions supplied with parts. Dryer works like new.
There are two screws that hold the switch in place. And two wires connected to the switch. The most difficult part of replacement is to place the new switch and hold it in place to reinstall the mounting screws. The space to work in is limited unless you remove the front panel from the dryer, which I opted not to do.
I am a 75 yr old woman. I cannot afford to have a service call plus parts. So I ordered the part from this company and used the video instructions to install. Now this should have been a 15 minute process but I was being careful.. I installed and pushed start and Hooray I did it