Lint has been bypassing the lint filter and building up in the fan (and duct)
I noticed that drying time was increasing. I took the covers off the dryer to reach the fan and discovered that the squirrel cage fan buckets were packed with lint, and therefore not moving the air as intended. This was because the original lint filter caught most of the lint, but some bypassed the lint filter and then built up in the fan wheel buckets. The lint bypassed the lint filter because there was no felt gasket on the original filter as far as I can tell. I replaced the lint filter...and the replacement filter includes the felt seal (and fits tightly in the slide). The original lint filter has a provision for the felt seal, but I don't recall ever seeing it (and I did not see remnants of it in the fan or duct). As a matter of fact, I was always suspicious of how loosely the lint filter fit in the slide. The felt seal is not available as a replacement part from Maytag. That said, felt material 3/16"x1/2"x10ft is available from McMaster-Carr...and it fits nicely in the original lint filter.
Parts Used:
Lint Filter
  • David from PINETOWN, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer would not heat up properly. It would heat initially but once the heat was off it would not come on again.
I followed the advice posted by other customers. I took the front off the dryer, put the door back in place and ran a cycle. I could see that the igniter was heating properly, but no gas was flowing. Based on what I read I concluded that it was a problem with one of the gas valve coils. It was relatively inexpensive to replace both (and the dry is 10 years old), so I didn't go to the trouble of determining the bad one. I replaced them both. Obviously I unplugged the dryer (no need to turn off gas). There were 2 screws that held the bracket in place which holds the coils. I disconnected the coils, removed the bracket screws, replaced the coils, reattached the bracket screws and reconnected the coils. I then reattached the front plate to the dryer. It was very easy and took about 20 minutes and I had never worked on a dryer before.
Parts Used:
M Series New Style Coil Kit
  • Joseph from Chicago, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Drum would not spin to drain water
Removed two screws and lifted the control console then tilted forward the shell. Removed two screws holding the latch cover and assembly then disconnected two wires. I played with the assembly until I discoved the element was toast. Ordered the part but when I got it I was confused because it had three prongs (two on one side and one on the other) when the burnt one had only one and one and I only had 2 disconnect wires. I thought I had gotten the wrong part but figured it out. Actually putting the assembly together was the easy part, trying to get the outer shell back together was a little tough. Between taking it a part, figuring out what was wrong and ordering and receiving the part was about three weeks. So when putting it all together took awhile but I did it and it works great.
Parts Used:
Lid Switch
  • Gay from Apple Valley, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
9 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Gas dryer would not heat - pilot lit briefly then went off
Same as others.
1. Unplug dryer from power source
2. Use nut driver to remove two front screws at bottom of dryer
3. Disconnect cable connected to Secondary Coil (this is the coil towards the rear of the dryer)
4. Use angled phillips screw driver to loosen screws holding cap on top of the two coils. (Angled tool not required but seemed easiest to me)
5. Slide top cap back towards lock screw to allow coil to be lifted out
6. Remove and replace secondary coil
7. Replace cap, tighten screws to lock in place, reconnect cable to coil
8. Restore power to dryer, test and confirm gas flame stays lit
9. Replace lower front panel on unit

PartsSelect a great resource to use for home repairs like these. My first time using site and doing this type of work, now PartsSelect my first source to go to on such items.
Parts Used:
M Series New Style Coil Kit
  • William from Chicago, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No heat...
Removed and replaced both the thermostat sensor and the ignitor. Tested thej dryer and it worked. Replaced the front panel and it was good to go.
Parts Used:
Dryer Radiant Flame Sensor
  • Charles from Long Beach, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
When door was closed the timer could be heard to continue clicking. also, drying cycle started immediately upon closing the door.
Two screws hold the top control panel in place. Once removed the panel could be tipped forward. The Push to Start switch had 2 wires which were removed and swapped to the new starter switch. The old one rotated 90 degrees to remove and the new one installed. Panel was resecured to the top of the dryer and tested. Worked first time. Finding the part on the website, ordering it, receiving it quickly and the install couldn't have been easier or more pleasant or efficient.
Parts Used:
Push-To-Start Switch - 2 Terminal
  • Theodore from Baraboo, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No Heat sometimes, But for a moment then None
First and Foremost i was told that my problem was with the Thermal Fuse (Fix Ya.com), Then with the little Electrical knowledge I have thought Fuses don't turn on and off,If the fuse was bad i would get No Heat. (Even for a second) Fuses just don't turn on and turn off intermittently,when they go there done! So after a little research i decided to order the gas coil valve. I tilted the top up, two screws on the front panel, took that off and the valves were exposed,(bottom left) two screws too remove bracket then installed new coils on bracket,put back together and I Have Heat Again! NO problems what so ever since new install. I would say having not been for cleaning lint build up inside the machine (been 6 years) the Whole project took me Ten Minutes.
Parts Used:
M Series New Style Coil Kit
  • Scott from Sacramento, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer was squealing
Disconnected Power cord, removed vent pipe, removed back panel, had to slide top cover off to remove additional screw holding back on. Went down to where the Idler Pulley was, removed old piece by depressing on the spring loaded actuator and slid it off the belt and all. Replaced same as removal.
Parts Used:
Idler Pulley
  • Kevin from VALDOSTA, GA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer had no heat at all. This is an older gas dryer.
Cleaned out years of fuzz behind lower access panel and noticed where the igniter sits there is a metal tube about 1 inch in diameter. It had rust on the end and was starting to flake away. Found some helpful hints about how to test the igniter. Very easy, just used an ohmeter. Unplugged the 2 pin wire connector and checked for continuity. 1 lead on 1 pin and the other on the other pin., igniter side not the harness side from the dryer. A good igniter should read less than 5 ohms. I don't know the spec. exacttly, but it should not read open or infinite resistance. My meter read an open circuit. Removed the tube and igniter assembly, mine only 2 small bolts. I found the igniter element cracked. Ordered and installed igniter and tube assembly. This was a very easy install. 20 year old dryer works great and it's better than spending $500.00+ on a new one.
Parts Used:
Burner Tube Igniter Kit
  • todd from MILFORD, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Wrench set
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Gas would not turn on after around 10 minutes of "normal" operation.
I've nothing to add to the techniques already described in the other narratives except that the dryer operated normally at first, but then after around 10 minutes the flame no longer cycled. I suspected a bad high limit thermostat since the valves seemed to be working. I ordered the replacement coils only because they were listed as the most common thing to fail. After replacing the T-Stat there was no change; I started checking things w/ a multimeter and found that all the T-Stats were closed. I should have done that at first. Anyway, since I had the new coils I decided to put them in. The dryer has workd perfectly ever since. Lesson to be learned: the coils may check ok when cold, but become inoperable after heating up a bit.
Parts Used:
Thermal Cut-Off Fuse Kit M Series New Style Coil Kit
  • Carmen from HOWELL, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers, Socket set
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The dryer would not heat up
After opening the bottom access panel, I found a lot of lint build up which is very flammable. I took my leaf blower and cleaned it all out. Then I just followed the instructions that came with the part. But be careful as the igniter is fragile. I broke the first one...
Parts Used:
Igniter Kit
  • William from Canyon Country, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My drier would start create heat,than stop heating after 8-10minutes.
After reading the many different common stories,I replaced both coils (m series).Very simply lifted up the top of driver,held by 2 snap springs and 2 lint vent screws.Removed front cover,2 screws and 2 bottom snaps,coils down on bottom left.r/r both coils,reinstalled covers and let there be heat!This website is a blessing!!
Parts Used:
M Series New Style Coil Kit
  • Tom from Schaumburg, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer heat would go off and timer would not move. Dryer would continuously run
Replaced coils on gas valve.
Parts Used:
M Series New Style Coil Kit
  • chuck from smithtown, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Too much drying time, not hot enough
I removed the Drier Door and removed the Front Drier Panel exposing the Gas Valve & associated parts. I removed two (2) screws holding the Gas Valve Coils in place & replaced the 2 terminal coil, then replaced the screws, Front Cover & Drier Door. I liked the results so much, I ordered the other Gas Valve Coil and will replace it also when it arrives.

Good trouble shooting information.
Parts Used:
M Series New Style Coil Kit
  • John from Floyd, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer would not run
There are two screws that hold the switch in place. And two wires connected to the switch. The most difficult part of replacement is to place the new switch and hold it in place to reinstall the mounting screws. The space to work in is limited unless you remove the front panel from the dryer, which I opted not to do.
Parts Used:
Lid Switch
  • james from york, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 11070902990