Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Icemaker Failed After 2 Years Top Of Line Unit
Removed plastic door over ice maker remove 4 screws and slide unit out after disconecting pull apart elect. Plug. Pop off side gear cover install on new and slide in, reconnecting electric plug as you go.
Disconnect power to refrigerator. Removed all food from Freezer. Removed all Shelves and shelf clips. Used phillips screwdriver and removed 6 screws from lower rear panel covering evaporator coil. Removed panel. Pulled plastic fan blade off top of motor shaft. Unclip top front of black motor retainer clip which then allowed the rear clip to unhook. Removed clip. Then removed 3 wires from fan motor, noting proper location for replacement. Slide the fan motor out to the left. Installed new motor. Reinstalled clip, hooking rear side first. Then rehooked the 3 wires. Slide fan blade back on top until secure. Tested everything at this point before reassembling rear panel. Then replace rear panel, replace the 6 screws, replace shelf clips and shelves and replace food. Very easy to do and saved about $150 over a service call to troubleshoot and re-visit to install after getting part
Replaced 8 cube ice maker assembly. Contrary to instructions I 1st removed 2 screws on the flapper door 2 removed 3 screws in bottom and 1 screw on right side bottom and pulled shelf out unplugged plug and lifted assembly off put new one on shelf plugged it in and slid it back into place replaceing. screws. was done in 10 min. start to finish . so far seems to have solved the problem.
Dog chewes up the original part. Got the replacement , put it on the filter turned to lock in place and tried tp pull out old filter ( same procedure has been done multiple times successfully) part broke instantly upon putting pressure tom pull out filter. Sent back to you the next day for replacement.
The hardest part was getting the front cover plate off. I used two kitchen knifes one in each slot on the bottom of the plate and pried it off and unplug it. I removed one screw to release arm. I then used long nose pliers to remove the pin on door arm assemble. Then unplug door heater. New door has no heater. The heater had cooked the plastic arm, which caused the arm to fail. Then reassemble in reverse order.
Emiter blinking red; ice maker stopped working. Called appliance repair, said electronic control boards needed to be replaced. Quoted me $275, including parts. Ordered part at partselect.com, installed in 15 min and ice maker started producing ice. Also discovered on other online forums that this part is a common failure on these model refrigerators. Very easy to swap out, plug & play. Make sure to unplug appliance before performing repair due to shock risk.
Taped plastic cover to get it out of the way with duct tape - removed three screws on each side - removed retaining screw for each module - carefully disengaged module using small flat head screw driver being sure to release the plastic retainer and then reverse the process. Be sure new modules snap into place.
Biggest problem was initially figuring out what the problem was. Turning off the ice maker had no effect and it just kept making ice.
Well I changed out the optical boards which I thought were the problem and the ice maker is still not making any ice. I can see the ice makers fingers rotating but there is no water entering through the tube. I jumped the water manifold in the back and water comes out but I cant figure out what is not telling it to run water and fill the ice tray. Any ideas would be appreciated I guess i'll replace the ice maker next. Thanks in advance.
Cracked Evaporation tray was leaking water on kitchen floor
I emptied refrigerator contents and tilted the refrigerator to the right so as to access the metal panel upon which the evaporation tray was resting. The metal panel is on the left side underneath the refrigerator and the evaporation tray is resting on the panel. I removed 4 screws that were holding the metal panel, pressed down on the panel, slid out the old, cracked plastic evaporation tray, inserted the new plastic evaporation tray, raised the metal panel to its original position, replaced the 4 screws, being careful not to pinched the water line that feeds the ice-maker. VOILA! Un-tilt the frig and re-stock it. It took a day for the temperature to stabilize, due to tilting, I think. New tray $45.
I took a 1/4 nut driver and removed the wire cover. I then used a small screwdriver to push up the clips the lock the unit in place. I then unplugged the unit and removed. I then used the same nut driver and removed the bottom plastic cover and installed it on the new icemaker. I then put the new unit part way back onto it slides, being carful to make sure the water fill spout clears the unit. Next I plugged in the wire harness and then slid the unit the rest of the way in until it locked in place. I then reinstalled the wire cover. This unit was delivered at 1:30 and it was installed by 2
Removal of the old assembly went quickly once I understood about the "push and release" tubing connectors. The exception was the connection from the water inlet assembly to the water filter which uses a different diameter connection at the inlet end, and would not "push and release". So to install the new valves, I simply by passed the old inlet assembly and used the extra push splicer furnished in the kit for the water inlet to the filter. All the other connections were easy push ins. Next time will be 1/2 hour maximum!
I removed the screws on the upper hinge and removed the door. I removed the lower cam in about 2 minutes and had it replaced. The upper cam was a tight fit in the door and I resorted to vise-grips to remove it. Total time to replace cams and put the door back on was 30 minutes. This saved me $100. Thanks