James
November 23, 2017
I am changing the control board because the fridge is stuck on express thaw and both the freezer and fridge are room temp. I hear the fan but not anything else, can it be just the board or the inverter and how to test the inverter. I will check the power to the inverter. Can just the control board cause this problem?
For model number zfsb23dndss