Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Bad thermistor
Took front cover off air conditioner and pulled it a little forward out of the outdoor housing. I then flipped the LED display section out to the left and exposed the patch panel. The next step was to remove the panel with a small screwdriver and disconnect the old thermistor plug. I then plugged in the new one, remove the old one from the grid bracket and placed the new one in. I then replaced everything else in reverse order. I have two LG air conditioners and they both have the same connection setup.
Bad thermister, unit would run constantly without cycling.
Remove the front cover. Slide the unit forward a few inches from the case. Remove 1 screw from the top on the control box. Unsnap the old thermister leads going into the circuit board. Snap in the new thermister and place the end in the plastic holder in front of the coils. Install front cover.
window air conditioner up and quit--not blowing warm air, just totally quit--nothing, nada
I hotwired the compressor and fan directly to 110 volts and it all functioned so I knew it was electronics. Ordered two circuit boards and after putting the first one in it fired right up. Returned the second one. The one that was bad had all the relays on it--the one with the digital readout and switches was good, which was great because the old remote continued to work. Not sure if a new board would work with the old remote or if the remote needed to be replaced also...