The refrigirator light would not come on.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Parts Used:
Light Switch
  • Jania from Novato, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
24 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator wasn't cooling
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires, it was really simple. I conected the new element & defrost themostat (instuctions were included with the parts). I replaced the cover pluged the fridge in everything was woking fine. I placed a themometer in the fridge & have been watching it for 2+ weeks now it is working fine. To anyone who is looking to do this repair, on thier own, I reccomend it. It was very simple & required little to no skill. No reasopn to throw away money to call a repair man.
Parts Used:
Defrost Heater Harness Kit Defrost Thermostat
  • James from LaGrange, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
19 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frost in ice chut, flapper hanging partially open.
Removed control panel, snapped out pretty easy. Removed flapper assembly (4 small screws). My spring was broke but it ended up being the solenoid assembly after I replaced the spring, door crank, micro switch and flapper it was obvious the solenoid was hanging up. I had to go back an order it but it was at my door 2nd day (quickly). I took the time to clean the area with Tylex (some mold), and everything went in easily. I didn't really need the new flapper, crank, and micro switch but they were fairly cheap and then all is new. We use our ice dispenser a great deal so I didn't want to have to go back in and fix a part I "should have" replaced. I used Part Select for my washer motor as well. Doing both repairs myself probably saved 3 or 4 hundred dollars easily.
Parts Used:
Dispenser Door Assembly or Flapper Lamp Socket Micro Switch Dispenser Door Recess Crank Recess Door Spring
  • John from Oxford, IA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
36 of 74 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
A piece of the crusher cover broke off into the ice bin
I removed the ice bin, removed the metal rod off the bottom, unscrewed all screws holding things together and then carefully pried the crusher assembly out of the ice bin. I made the mistake of doing it when the bin was still frozen and ended up cracking it where the "clips" from the crusher are inserted. It was much easier after the bin warmed up.

Replaced and put everything back together.
Parts Used:
Dispenser Crusher Cover
  • David from Woodland Hills, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
18 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice & water dispenser wouldn't shut off
Took the trim piece off, took 4 screws out & replaced the part. Problem solved!
Parts Used:
Ice Funnel - White Micro Switch Dispenser Housing Shield
  • eve from carrollton, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
23 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Ice Bucket Was Cracket And The Auger Also Broken.
I was able to order the correct parts . Needed my son in law (who in an engineer) to put it together. It was sort of a challenge forhim too. W the persons that I spoke to were very helpful and very nice and the parts came quickly. Thank heavens for the internet. The part that was broken was inside the freezer part of my frig.
Parts Used:
BUCKET AUGER Housing Crusher Dispenser
  • Sharon from Glendale, AZ
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
18 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker supply hose leaking at freezer entrance
I did it the way you recommended except rather than removing the existing tube from the water valve at the bottom of the fridge I cut the existing and new tubes and then spliced the new tube to the old tube. I already had the splicer nut so it was quicker and easier. By the way, shipping was very quick and you prices and your website are excellent!
Parts Used:
Grommet / Tube Assembly
  • Michael from Meridian, MS
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Wrench set
18 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Flapper not sealing. Frost buildup on inside of freezer door
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
Parts Used:
Dispenser Door Assembly or Flapper
  • D from ZELLWOOD, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
15 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
loss of refrigeration
After mopping up the floor - the whole freezer that was iced up melted - that's how I found out about the problem...

Disconnected the power, emptied the freezer, removed the shelves. Under the ice maker was the light cover - I removed that first, then the two screws holding the back panel in place - The light panel was covering the top screw.

With the screws removed, I pulled out the back panel - which needs to be jiggled around a bit to get it past the shelf brackets.

With the cover off, I could see the mostly de-iced coil at the back of the unit. The defrost heater was visible at the bottom of the coil frame. To remove the bracket/heater, I removed the two cross head screws (one on each side) holding the bracket to the coil frame. I then twisted the side tabs of the bracket assembly and pulled the entire bracket/heater/wiring from the coil frame.

With better access tot he bracket/heater I was able to disconnect the wires. I grabbed the new bracket/heater, reattached the wires and pushed the bracket/heater back onto the coil frame and closed the side tabs firmly attaching the bracket to the frame. I then screwed the tabs back onto the frame.

Replaced the back panel, screwed it in place. Put back the light cover and then the shelves. Turned the appliance back on and left it for a few hours - before checking to see if there was any drop in temperature. There was, so after 24 hours or so I reloaded all the food...

NOTE: I was certain that the heater had failed! When I pulled the OLD one out it was obviously burned out - the glass tube was blackened and pieces of the element could be seen in the bottom of the tube.
Parts Used:
Defrost Heater Harness Kit
  • Heather from Pennington, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Parts Used:
Light Switch
  • Terry from Simi Valley, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My 13 yr grandson assisted me on this
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch
  • Sherry from Auburn Hills, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice auger was broke and ice was freezing in the recess door
all parts worked and were easy to install. probably saved me from having to buy a new fridge. ice maker is working fine and recess door flap is closing correctly. very satisfied.
Parts Used:
Dispenser Door Assembly or Flapper Ice Bucket and Auger Assembly Dispenser Door Recess Crank Recess Door Spring
  • danny from west potsmouth, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
21 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser Fan Motor stopped turning
1. Unplugged the fridge. 2. unplugged the fan connection and removed the wire holding clip. 3. removed the 2 screws holding the motor bracket in place and removed the bracket. 4. Pulled gently back on the motor so that the fan pressed against the front bracket until the fan slid off the motor shaft. 5. Pulled the rubber motor mounts off of the old motor and placed on the new motor. 6. Slide the new motor in place pressed the fan all the way onto the shaft. 7. Placed the rear motor bracket in place and started the screws by hand making sure the ground wire was attached to the furthest away screw. 8. tightened the screws down. 9. Pushed in the wire holding clip into the clip hole. 10. Plugged back in the fan. 11. Plugged back in the fridge. 12. Turned down the temp on the fridge to kick on the compressor and checked to assure the fan was operating and then set the temp back to normal. 13. Vacuumed the condenser coils to get them all clean and ready for more years of service!
Parts Used:
Condenser Fan Motor
  • Arthur from Alamosa, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker not making ice
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
Parts Used:
Ice Maker
  • Cristina from Los Angeles, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
16 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
when dispensing ice the flap door would not open properly and was open most of the time causing the door to ice up...cause solenoid was rusted badly
I removed the screws for the inner door and removed inner lining. Then took out the ice dispenser in the door. Took off control panel on the front of the ice panel. Removed the rusted parts and put in new parts. Put all parts back the way it came apart. In retrospect.... I could have possibly replaced the parts from the front panel but by taking apart the door...I had to thaw out the inner panel and insulation with in the door.
Parts Used:
Dispenser Door Solenoid Assembly Dispenser Door Assembly or Flapper Dispenser Door Recess Crank Recess Door Spring
  • calvin from annapolis, MD
  • Difficulty Level:
    Easy
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
19 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!