Solenoid controlling the valve had stopped operating.
I first tested to make sure the solenoid was receiving power. Every time the arm on the ice maker cycled, the meter would go up to 120v for about 10-15 seconds, and then back to almost 0, so I knew the electical control and timer was working as it should.
The valve was easy to change - took about 20 minutes total (including pulling the fridge out and pushing it back in). I just turned the water off, removed the valve assembly from the fridge, and took all of the lines off of the old one. I then hooked up the supply line to the new valve assembly. The lines to the water and ice had compression fittings on them, but the new vavle has a "push-in" connector. So, I cut the old water and ice lines squarely, just past the fitting, then pushed them in firmly. Plugged the connectors in, re-attached the vavle assembly to the fridge, turned the water back on, and viola - I had ice in about an hour! Gravy! :)
Removed panel from inside the back of the freezer section, by removing four screws. Then, sprayed the ice build-up on the coils, with hot water until all of the ice was melted away. (Note: be certain to plug the drain hole, and use several towels to catch the water drainage. ) Removed the Defrost Heater Element by removing two holding screws. Unplug the unit and pluged-in the new unit and replaced all screws as originally mounted.
Refrigerator is not cooling. Light and fan working. Changed the capacitor.. Still not cooling. Back to discovery mode.It may be the timer Certainly not PartSelect's fault. They have great service.
Unplugged frige, removed top shelf, pulled broken fan blade off. Replaced with fan blade just purchased from PartSelect. Very simple repair. Orderd and recieved the right part.
Cams on Hinge assembly broken, door didn't close properly
I supported door with 2* 6 scrap wood. I used cedar shingles to raise door to correct height. Using a socket wrench, I removed the hinge from the fridge and the cam assembly from the door. I installed the new hinge and cam using the shims thatwere behind the original parts. I removed the 2*6 supports and the door now works perfectly.
Refrigerator would begin to lose it's cool and we saw ice caking on the bacjk panel of the freezer section.
We had to empty the freezing section, remove the 4 screws that held the back panel and defrost the coils. Then with the diagram we got from the internet, we removed the defroster and easily installed the new one and put the back panel back on. We did find later that it was still icing over so I ordered the thermostat and we installed it today. It too was easy to install. We spliced the wires and hooked the new thermostat to the old wires and reinstalled the back panel. Hopefully this will solve the problem for us now.
Shut off water and disconnected at factory joint at bottom hinge. Unplugged the electrical at the top hinge. Removed the door and installed new bottom hinge and cam assembly. Reinstalled the door and hooked water and electric back up. Part worked fine.
Removed the ice maker from the freezer. Removed the switch. Tested the switch with a multimeter. Ordered a new switch. Replaced it in the box. Installed the ice maker ( 3screws and electric cord plug. It works. Details available on the internet.
Coils in Freezer over frosted restricting air flow.Warm Frig.
1) Unplug Refrigerator. Remove all shelves and light shield in the freezer. 2)Remove panel covering refrigeration coils inside freezer in back. Two hex head screws w/nut driver. 3)Remove the defrost heater using phillips screw driver. Two screws. 4)Unplug two quick disconnect stakons and wires from heater. 5)Plug the wire coming down the right side into one side of the new heater and plug the shipped white wire into the other quick disconnect spade at the heater. 6)Install the new dual element defrost heater into the same place where the old was. Connections to the right. 7)Route the wire that was on the left across the top of the coils and down the right side. 8)Bring the existing wire from the left side down the right side and the white wire up the right side. Wires should not be tight at all and do not remove the tape at the stakon. 9)Now wires need to be cut (if necessary)and crimped together in the shipped stakon. This stakon looks like a wire nut. 10)Wires should be tucked gently into the styrofoam up and down the right side. Wirenut should be positioned so that water can not collect in it. 11)Replace the panel over the cooling coils. 12)Plug Refigerator back into the wall outlet. Put shelves and light shield back in. 13)My refrigerator is now working without a problem. It's been est two weeks. Ice maker is also working correctly.
Removing gasket by pulling it back to expose 1/4" screws and replacing with the new one was easy. What was a HORROR- was that the new gasket doesn't seal against the door properly, and door doesn't want to close at all. to remedy this we had to put packing tape along the outer portion of the gasket all along the door to hold it donw, in order for the door to close. This is "possibly" becuase I overtightended the screws that hold the metal brace that holds down the gasket. Don't make this mistake and if you do, packing tape is the answer.
Pretty much self explanatory.Removed drawer and anything on top of glass shelf.Remove two screws holding on slide.Replace with new slide.Repeat on other side.Replace shelf and drawer.
This part (plastic tubing) does not show up under my model of refrig...so I had to look thru the various water lines and pick the one that "looked" right. Luckily, this is the exact replacement part and works perfectly. I removed the lower back panel from the fridge, removed the bracket holding the water line connectors and pressed the outer ring of the coupler up until it released the old water line. I pushed in the new line, made sure it was snug with a gentle pull and ran the line under the fridge up to the existing coupler. I removed the old line from the existing coupler under the front left of the freezer door, and pushed in the new line. I did not need to use the new coupler. If my old line would not have been so brittle and cracked in several places, I could have just cut out the leaking portion and popped the new couple in to mend the line back together. Easy job and we can stop buying bottled water at the store now!